Skin temperature at top and bottom of clay tiles, exposed to sun, were measured during the day from 08 A.M to 03 P.M. continuously for a few months during summer, in order to assess the ability of this material to prevent the heat of summer from causing soaring of temperature inside the rooms due to direct exposure of roof to sun. The major parameters were (i) the composition of the base-material, which consisted of clay and pit sand in various proportions, (ii) the thickness of the tiles and (iii) whether the tiles were baked or unbaked and their combination. The results show that unbaked tiles have less thermal conductivity than baked tiles. However, if placed in proper combination, a total thickness of six inches would suffice for complete thermal insulation against direct exposure of roof to the sunshine. It is observed that, when the temperature was 47°C, a reduction of 15°C was achieved with a total thickness of six inches which consists of 2-inch thick baked tiles at the bottom (placed directly on steel tiers as ceiling), unbaked layer of 2 inches in the middle, and two-inch thick tiles (as roof pavement) on the top.