Continuous measurement of traditional air pollutants alongwith meteorological parameters was carried out by air pollution Mobile Monitoring Laboratory at industrial areas of Karachi. Average concentration of SO2 `at Sindh Industrial Trading Estate was found to be 24.9 µg/m3 and PM 10 (Particulate matter) was 176.5 gg/m3, whereas the average concentration of $02 at Korangi Industrial Area was 7.4 gg/m3 and PM 10 was 147.2 gg/m3 respectively. These data were compared with the uptown area of Karachi. The result suggested that SO2 and PM 10 found in these areas shows similar variation, which indicates that, these pollutants originate from the same source. Effect on human health is also discussed.