Comparison between clinical evaluations, stereoscopic photographic analysis and confocal scanning laser ophthalmoscope in estimating cup/disc ratio.

Author(s)
M. S. Shehzad Layton Rahmatullah Benevolent Trust (LRBT) Eye and Cancer Hospital, Lahore, Pakistan
K. M. Ashraf Layton Rahmatullah Benevolent Trust (LRBT) Eye and Cancer Hospital, Lahore, Pakistan
M. Siddique Layton Rahmatullah Benevolent Trust (LRBT) Eye and Cancer Hospital, Lahore, Pakistan
Z. A. Qazi Layton Rahmatullah Benevolent Trust (LRBT) Eye and Cancer Hospital, Lahore, Pakistan
M. T. Khan Layton Rahmatullah Benevolent Trust (LRBT) Eye and Cancer Hospital, Lahore, Pakistan
Abstract
To find out the agreement in cup/disc ratio measurements obtained by clinical evaluation, analysis of stereoscopic photographs of optic disc, and Confocal Scanning Laser Ophthalmoscope (Heidelberg Retina Tomograph II Software Version 1.5) in healthy persons and patients with early glaucoma. Thirty healthy persons and thirty patients with early and moderate primary open angle glaucoma were selected on simple random basis. Two expert ophthalmologists evaluated the cup disc ratio with Ophthalmoscope and slit lamp examination with 90 D super field lens. Simultaneous Stereoscopic Optic nerve head photographs were then projected on Topcon Image net system for Cup Disc ratio evaluation. Heidelberg Retina Tomograph II (HRT II) software version 1.5 (Heidelberg Engineering Germany) was performed in all cases and cup disc ratio was obtained. Computer based SPSS program was used for Comparison between these 3 values. Mean difference between clinical evaluation and automated analysis by HRT II was -0.11±0.03 and -0.15±0.05 for horizontal and vertical cup/disc ratio respectively for ophthalmologist A and -0.09±0.03 and -0.06±0.03 for horizontal and vertical cup/disc ratio respectively. Mean difference between photographic evaluation and automated analysis by HRT II was -0.08:t0.02 and -0.15:t0.03 for horizontal and vertical cup discratio respectively for Ophthalmologist A and 0.05±0.03 and -0.06±0.03 for vertical and horizontal cup disc ratio for Ophthalmologist B. The automated techniques showed a greater difference in estimating Cup Disc ratio from clinical assessment then from stereoscopic photographs. There was a fair to moderate agreement in vertical cup discratio by the three techniques and moderate agreement in horizontal cup disc ratio.
Publication Details
Page(s) 225-228
DOI DOI not available
Published Journal: Journal of Pakistan Medical Association, Volume: 53, Issue: 6, Year: 2003