Percutaneous reduction of radial neck fractures in children.

Author(s)
Zafar Durrani Department of Orthopaedic and Trauma, Khyber Teaching Hospital, Peshawar, Pakistan
Muhammad Shabir Department of Orthopaedic and Trauma, Khyber Teaching Hospital, Peshawar, Pakistan
Abstract
To evaluate the result of percutaneous reduction of radial neck fractures in children. This study was conducted in the Department of Orthopaedic and Trauma. Khyber Teaching Hospital. Peshawar, from December 2001 to December 2003. Twenty five children with radial neck fracture angulated more than 30 dagree who did not respond to close reduction were included in the study. All these fractures were reduced with percutaneous Kirschner wire under general anaesthesia with image intensifier. After reduction a back slab was given without fixing the fracture for three to four weeks. Results evaluated clinically as well as radiologically and graded excellent, good, fair and poor. Male to female ratio was 3: 1. We got excellent results in 14 (56%), good 10 (40%), fair in 1 (4%) and poor in none. Percutaneous Kirschner wire reduction of radial neck fracture in children is a useful choice, which gives excellent results in majority of cases.
Publication Details
Page(s) 97-100
DOI DOI not available
Published Journal: Journal of Surgery (PIMS), Volume: 26, Issue: 2, Year: 2003