Investigations on high-strength concrete with crushed-brick coarse aggregates.

Author(s)
Tahir Kibrya Military College of Engineering, Risalpur, Pakistan
Abstract
This investigation explores the possibility of using crushed brick aggregate, obtained from high quality bricks with high crushing strength and low absorption, in the manufacture of high-strength concrete and compares the performance of such concrete with high-strength concrete prepared with normal aggregate. Compressive strengths of 60 and 80N/mm2 were successfully achieved using crushed brick coarse aggregates, obtained by the manual crushing of bricks with average crushing-strength of 40N/mm2. The flexural strength of brick aggregate concrete in the high-strength range was observed to be between 8 and 11 % of the compressive strength, similar to high-strength concrete with normal aggregate. The average static modulus of elasticity for concrete with engineering brick aggregate was observed to be 36 % lower than concrete with normal aggregate and the average dynamic modulus of elasticity was 38 % lower. The density was found to be about 6 % lower. Initial surface absorption for high-strength concrete with brick aggregates was observed to be similar to high-strength concrete with normal aggregate. A design-procedure for design of high-strength concrete mixes with crushed brick aggregates is proposed.