No Detail Found!

Mass transfer parameters for a reactive system in an extraction column. part-II: comparison with model predictions.

Author(s)
M. T. Saeed R.I.Divison PCSIR Lab complex, Shahrah-e-Jalal-u-Din Roomi Lahore, Pakistan
M. A. Butt Institute of Chemical Engineering & Technology, Punjab University, Lahore, Pakistan
Z. H. Rizvi Institute of Chemical Engineering & Technology, Punjab University, Lahore, Pakistan
Abstract
Experimentally estimated values of mass transfer coefficients, already presented in Part I of this paper, are compared with those predicted from single drop correlations for the continuous and dispersed phase. The system used is the extraction of zinc ions from acidic aqueous sulphate solution by di (2-ethylhexyl) phosphoric acid (DEHPA) in n-heptane diluent.. It has been found that results are in agreement with single drop correlations and the ones predicting best results are given for design purposes.
Publication Details
Page(s) 47-52
DOI DOI not available
Published Journal: Journal of Pakistan Institute of Chemical Engineers, Volume: 32, Issue: 1--4, Year: 2003