No Detail Found!

Outcome and Complications of Proximal Humeral Fractures after ORIF with Angular Stable Plating: A Single Center Study

Author(s)
Salahulddin Abuljadail Department of Orthopaedic, College of Medicine, King Faisal University, 31982, Al-Ahasa, Saudi Arabia; King Fahad Hospital, Hofuf, Saudi Arabia
Abstract
Background: The incidence of proximal humeral fractures has increased in the last decades. There is still a debate regarding conservative and operative indication and type of fixation or replacement. Therefore, long-term post-therapeutic follow up is essential to identify the posttherapeutic outcome of different interventions. In this context, fracture registries were recently introduced and facilitated outcome improvement. The goal of this research is to review the post-therapeutic outcome and complication of proximal humeral fractures after management with ORIF with angular stable plating. Methods: All patients who had a proximal humeral fracture and were managed with angular stable plating over 10 years period (2012-2022) in King Fahad Hospital Hofuf were identified. AO/OTA and Neer classification systems were used. Long-term functional outcome was assessed primarily through a validated patient-reported questionnaire, the Munich Shoulder Questionnaire (MSQ), from which Constant score equivalents were derived. We analyzed the demographic data like age, follow up interval, fracture type and functional parameters of the MSQ and Constant score. Exclusion criteria were patients with: polytauma, open fractures, neurovascular associated injuries, neurological disorders, follow up under 12 months, patients younger than 16 and older than 95 years old and patients unable to consent. Results: All Patients with proximal humeral fractures who were treated with angular stable plating (n = 595) were identified in our center between 2012-2022 with female predominance (n = 378; 63,6%). About 268 questionnaires were successfully completed (45% response rate). 268 patients were managed with angular stable plating with 3- and 4-part fractures was 160 and 108 respectively. Mean MSQ score after angular stable plating of 3and 4-part fractures was 86,3 and 72,8 respectively. Postoperative complications after angular stable plating were: 2,5% secondary varus malalignment, 2,23% AVN, 2,61% shoulder stiffness, 0,37% shoulder impingement, 2,61% cut out, 0,74% non-union. Conclusion: In this single-center retrospective cohort, ORIF with angular stable plating was associated with generally acceptable patient-reported functional outcomes and a relatively low recorded complication frequency among respondents. The most commonly recorded complications were screw cutout and shoulder stiffness. These findings should be interpreted cautiously because of the retrospective design and the 45% questionnaire response rate.
Publication Details
Page(s) 230-234
Published Journal: Journal of Pioneering Medical Sciences, Volume: 15, Issue: s1, Year: 2026

Request the full text from PASTIC

Keywords
outcome, PROM, Fracture Register, Patient-Rated Outcome Measure, Proximal humerus, Function, Shoulder
References
Court-Brown C.M. . .The epidemiology of proximal humeral fractures. ” Acta Orthopaedica Scandinavica, 72(2001) : 365-371.
Neer C.S. “ . .Displaced proximal humeral fractures. I. classification and evaluation. ” Journal of Bone and Joint Surgery, 52(1970) : 1077-1089.
Neer C.S. “ . .Displaced proximal humeral fractures. II. Treatment of three-part and four-part displacement. ” Journal of Bone and Joint Surgery, 52(1970) : 1090-1103.
Kristiansen B. and H.,Kofoed B. and H. . .Transcutaneous reduction and external fixation of displaced fractures of the proximal humerus: A controlled clinical trial. ” Journal of Bone and Joint Surgery, 70(1988) : 821-824.
Darder A. . .Four-part displaced proximal humeral fractures: Operative treatment using Kirschner wires and a tension band. ” Journal of Orthopaedic Trauma, 7(1993) : 497-505.
Fakler J.K. . .Current concepts in the treatment of proximal humeral fractures. ” Orthopedics, 31(2008) : 42-51.
Beirer M. .2017 .Development of a German fracture register to assess current fracture care and improve treatment quality: A Feasibility Study. EFORT Open Reviews, 2(12) : 474-477.
Gupta A.K. . .Surgical management of complex proximal humerus fractures-A systematic review of 92 studies including 4500 patients. Journal of Orthopaedic Trauma, 29(2015) : 54-59.
Ruch D.S. . .Fixation of Three-Part Proximal Humeral Fractures: A Biomechanical Evaluation. ” Journal of Orthopaedic Trauma, 14(2000) : 36-40.
Herscovici D. .2000 .. Percutaneous Fixation of Proximal Humeral Fractures.” Clinical Orthopaedics and Related Research, (375) : 97-104.
Bogner R. .2008 .Minimally-invasive treatment of three- and four-part fractures of the proximal humerus in elderly patients. ” Journal of Bone and Joint Surgery, 90(12) : 1602-1607.
Rajasekhar C. . .Fixation of Proximal Humeral Fractures with the Polarus Nail. ” Journal of Shoulder and Elbow Surgery, 10(2001) : 7-10.
Agel J. . .Treatment of proximal humeral fractures with polarus nail fixation. ” Journal of Shoulder and Elbow Surgery, 13(2004) : 191-195.
Wheeler D.L.,Colville M.R. . .Biomechanical comparison of intramedullary and percutaneous pin fixation for proximal humeral fracture fixation. ” Journal of Orthopaedic Trauma, 11(1997) : 363-367.
Adedapo A.O.,J.O. Ikpeme. “ A.O. . .The results of internal fixation of three- and four-part proximal humeral fractures with the polarus nail. ” Injury, 32(2001) : 115-121.
Egol K. . .Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures. ” Journal of Shoulder and Elbow Surgery, 21(2012) : 741-748.
Gradl G. . .Biomechanical evaluation of locking plate fixation of proximal humeral fractures augmented with calcium phosphate cement. ” Journal of Orthopaedic Trauma, 27(2013) : 399-404.
Hertel R. . .Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. ” Journal of Shoulder and Elbow Surgery, 13(2004) : 427-433.
Jobin C.M. . .Reverse shoulder arthroplasty for the management of proximal humerus fractures. ” Journal of the American Academy of Orthopaedic Surgeons, 23(2015) : 190-201.
Antuna S.A. . .Shoulder hemiarthroplasty for acute fractures of the proximal humerus: A minimum five-year follow-up. ” Journal of Shoulder and Elbow Surgery, 17(2008) : 202-209.
Yang S.H. . .Shoulder hemiarthroplasty for the treatment of complex proximal humeral fractures. Chinese Journal of Traumatology, 12(2009) : 14-17.
Hawkins R.J. and P.,Switlyk R.J. and P. .1993 .Acute prosthetic replacement for severe fractures of the proximal humerus. ” Clinical Orthopaedics and Related Research, (289) : 156-160.
Cuff D.J.,Pupello D.R. .2013 .Comparison of hemiarthroplasty and reverse shoulder arthroplasty for the treatment of proximal humeral fractures in elderly patients. ” Journal of Bone and Joint Surgery, 95(22) : 2050-2055.
Grassi F.A. . .Six-year experience with the delta iii reverse shoulder prosthesis. ” Journal of Orthopaedic Surgery, 17(2009) : 151-156.
Klein M. .2008 .Treatment of comminuted fractures of the proximal humerus in elderly patients with the delta III reverse shoulder prosthesis. ” Journal of Orthopaedic Trauma, 22(10) : 698-704.
0

Citations

0

Downloads

18

Views