No Detail Found!

Spontaneous and Early Fracture of Hemodialysis Catheter leading to Embolization and Endovascular Emergency

Author(s)
Muhammad Jamil Assistant Professor, Department of General Medicine, North Eastern Indira Gandhi Regional Institute of Health & Medical Sciences, Meghalaya, India
Habib Muhammad Reazaul Karim Senior Resident, Department of Anaesthesiology and Critical Care, North Eastern Indira Gandhi Regional Institute of Health & Medical Sciences, Meghalaya, India
Akash Handique Associate Professor, Department of Radiology & Imaging, North Eastern Indira Gandhi Regional Institute of Health & Medical Sciences, Meghalaya, India
Muhammad Yunus Additional Professor and Faculty In Charge, Department of Anaesthesiology and Emergency Medicine, North Eastern Indira Gandhi Regional Institute of Health & Medical Sciences, Meghalaya, India
Abstract
Hemodialysis through a central venous catheter (CVC) is advised to be used only in acute renal failure setting and as temporary bridging access for patients awaiting arterio-venous fistula. However, it is not uncommon to even patients with end stage renal disease (ESRD), to have their hemodialysis done through temporary CVC for long duration without any attempt to have permanent access. Complications are not uncommon with such lines. Commonly encountered complications are infection, thrombosis, haemorrhage, arterio-venous malformation, and pseudoaneurysm etc. Among the uncommon complications, migration of fractured CVC, migration of guide wire, fracture of the tip of catheter with embolization etc are described. We report an early fracture (on 3rd day) of a femoral venous catheter and embolization leading to an emergency in a 44 year old woman with ESRD which was successfully retrieved by endovascular intervention.
Publication Details
Page(s) 97-99
DOI DOI not available
Published Journal: Journal of Pioneering Medical Sciences, Volume: 6, Issue: 3, Year: 2016

Request the full text from PASTIC

Keywords
Central venous catheter, complication, Fracture and Embolization, Hemodialysis, Interventional radiology
References
Santoro D,Filippo Benedetto F,Mondello P,Pipito N,Barilla D,Spinelli F .2014 .Vascular access for hemodialysis: current perspectives. International Journal of Nephrology and Renovascular Disease, 7 : 281-94.
Tordoir J,Canaud B,Haage P,Konner K,Basci A,Fouque D .2007 .European best practice guidelines (EBPG) on vascular access. Nephrol Dial Transplant, 22(Suppl 2) : ii88-117.
Kher V. .2002 .ESRD care in developing countries. Nephrology forum. Kidney Int, 62(1) : 350-62.
Kher V .2011 .Tunneled central venous catheters for dialysis - A necessary evil?. Indian J Nephrol, 21 : 221-2.
Haddad NJ,Cleef SV,Agarwal AK .2012 .Central Venous Catheters in Dialysis: The Good, the Bad and the Ugly. The Open Urology & Nephrology Journal, 5(Suppl 1) : 12-18.
Ethier J,Mendelssohn DC,Elder SJ,Hasegawa T,Akizawa T,Akiba T .2008 .Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study. Nephrol Dial Transplant, 23(10) : 3219-26.
DJ Kutter .2004 .Thrombotic complications of central venous catheters in cancer patients. Oncologist, 9(2) : 207-16.
Cruz SD,Gupta M,Kaur R .2013 .Fracture of temporary femoral haemodialysis catheter: our experience. BMJ Case Reports, : bcr2013009625.
Raymond-Carrier S,Dube M,Nolin L,Quimet D,Leblanc M. .2003 .Hemodialysis catheter tip embolization in the right pulmonary vasculature: report of a cardiac arrest. ASAIO J, 49 : 751-4.
Reynen K. .1993 .-year follow-up of central embolization by a guide wire [letter]. N Engl J Med, 329(13) : 970-1.
WL Scott .1988 .Complications associated with central venous catheters. A review. Chest, 94(6) : 1221-5.
Bessoud B,de Baere T,Kuoch V,Desruennes E,Cosset M-R,Lassau N .2003 .Experience at a Single Institution with Endovascular Treatment of Mechanical Complications Caused by Implanted Central Venous Access Devices in Pediatric and Adult Patients. AJR, 180(2) : 527-32.