No Detail Found!

Effect of Torx and Torx+ Screw Head Geometry on Torquing Cycles to Stripping Point in Two Implant Systems: An In Vitro Study

Author(s)
Mosa Altassan Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
Nabeel M. Munshi Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
Bashayer Alzahrani General Dentist, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
Shooq Alharbi General Dentist, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
Abdulmajeed Alghanemi General Dentist, King Abdulaziz University, Jeddah, Saudi Arabia
Osamah Alsulimani Department of Oral and Diagnostic Sciences, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
Abstract
Background: Screw head stripping remains a clinical challenge in implant dentistry because it complicates retrieval, increases treatment costs, and may compromise long-term prosthesis stability. Although various screw head geometries have been developed to improve torque transfer and reduce mechanical wear, comparative evidence on their performance under repeated tightening and loosening is limited. This study evaluated the resistance of Torx and Torx Plus (Torx+) screw designs to stripping under repeated torque cycles. Methods: Thirty titanium abutments with corresponding screws were divided into two groups (n = 15): Group A (Torx) and Group B (Torx+). Each fixture was embedded in acrylic resin and subjected to cycles of tightening to 35 Ncm followed by complete loosening. Baseline and follow-up surface changes were examined using scanning electron microscopy (SEM) at 10 cycles and at the point of stripping. The number of cycles until stripping was recorded, and the groups were compared using an independent samples t-test (SPSS v26, a = 0.05). Results: The Torx group withstood a significantly greater number of cycles before stripping (mean 60.47±5.58) than the Torx+ group (mean 30.13±5.66) (t = 18.76, p<0.001). SEM analysis revealed irregular material displacement in Torx screws, whereas Torx+ screws showed edge rounding and smoother abrasion. Conclusions: Screw head geometry influences resistance to stripping. The Torx design demonstrated superior durability compared with Torx+, indicating potential advantages for clinical situations that require repeated screw manipulation. Further research is needed to confirm these findings in vivo and to assess other geometries.
Publication Details
Page(s) 185-190
DOI DOI not available
Published Journal: Journal of Pioneering Medical Sciences, Volume: 15, Issue: 5, Year: 2026

Request the full text from PASTIC

Keywords
Torx Design, Screw Head Geometry, Torquing Cycles, Dental Implants, Screw Stripping
References
McGlumphy E.A.,Mendel D.A.,Holloway J.A. . .Implant screw mechanics. ” Dental Clinics of North America, 42(1998) : 71-89.
Balubaid A.S. “ .2022 .Screw loosening among different angles of dynamic abutments. Science Journal of Research Publications, : .
Alnasser A.H. . .Evaluation of implant abutment screw tightening protocols on reverse tightening values: An in vitro study. The Journal of Prosthetic Dentistry, 125(2020) : 486-490.
Maalhagh-Fard A.,Jacobs L.C. . .Retrieval of a stripped abutment screw: A clinical report. The Journal of Prosthetic Dentistry, 104(2010) : 212-215.
Ghaffari T. . .Evaluation of implant abutment screw head deformation in hexagonal and star designs after successive tightening and loosening. ” Journal of Advanced Periodontology and Implant Dentistry, 15(2023) : 61-65.
Misch C.E. .2015 .Principles for abutment and prosthetic screws and screw-retained components and prostheses. , : 724-752.
Lin C.H.,Chao C.K.,Tang Y.H.,Lin J. . .Improving socket design to prevent difficult removal of locking screws. ” Injury, 49(2018) : 797-802.
On S.W. . .Fracture and fatigue of dental implants fixtures and abutments with a novel internal connection design. ” Journal of Functional Biomaterials, 13(2022) : 239.
Friedrich C.,Design Mechanical .2003 .Simulation for Material Selection. , : 356-369.
Hughes J.M.,Practical J.M. .2015 .Electronics: Components and Techniques. Elsevier, : .
Al-Shammari A. .2012 .Correlation between screwdriver tip angle and torque characteristics of fasteners. , : .
Jaarda M.J.,Razzoog M.E.,Gratton M.E. . .Providing optimum torque to implant prostheses: A pilot study. ” Implant Dentistry, 2(1993) : 50-52.
Winkler S. . .Implant screw mechanics and the settling effect: An overview. ” Journal of Oral Implantology, 29(2003) : 242-245.
0

Citations

0

Downloads

18

Views