No Detail Found!

The Impact of Combining Engaging and Non-Engaging Abutments in Multi-Unit Implant Prosthesis

Author(s)
Mosa Altassan Department of Oral and maxillofacial Prosthodontics, Faculty of Dentistry, king Abdulaziz University, Jeddah, Saudi Arabia
Abstract
Objectives: The selection of abutment type plays a decisive role in the long-term success of multiunit implant-supported prostheses. Engaging abutments are designed to enhance mechanical stability through antirotational features, yet their use in multiunit situations often complicates the achievement of a passive fit. In contrast, non-engaging abutments allow greater flexibility for non-parallel implants but may increase the risk of screw loosening and prosthetic complications. Hemi-engaging configurations have been introduced as a hybrid approach to balance stability with prosthetic adaptability in multiunit prostheses. The aim is to provide clinicians with an updated overview of the mechanical implications of hemi-engaging abutments, supporting evidence-based decision-making in multiunit implant prosthesis. This review analyzes experimental evidence from in vitro mechanical testing and finite element analysis published over the last 15 years that evaluate the mechanical behavior associated with these abutment types. Searches were conducted in PubMed, Scopus and Google Scholar. The review highlights variations in stress distribution and component durability associated with each abutment type, while also identifying inconsistencies across studies. Key findings reveal that Non-Engaging (NE) configurations offer superior tolerance to prosthetic misfit, while Hemi-Engaging (HE) designs demonstrate a dramatic increase in fatigue life and fracture resistance-up to 17fold in some studies. Evidence on stress distribution remains conflicting and no significant advantage was found for HE designs in maintaining screw preload or minimizing microgaps. The current lack of clinical evidence highlights the need for well-designed trials to confirm laboratory findings and guide evidence-based practice.
Publication Details
Page(s) 67-73
DOI DOI not available
Published Journal: Journal of Pioneering Medical Sciences, Volume: 15, Issue: 4, Year: 2026

Request the full text from PASTIC

Keywords
Finite element analysis, Engaging Abutments, Screw loosening, Non-Engaging Abutments, Stress Distribution, Hemi-Engaging Abutments
References
Pjetursson B.E. .2012 .A systematic review of the survival and complication rates of implant-supported Fixed Dental Prostheses (FDPs) after a Mean Observation Period of at Least 5 Years. Clinical Oral Implants Research, 02546(2012) : 0501-38.
Goodacre C.J. . .Clinical complications with implants and implant prostheses. ” Journal of Prosthetic Dentistry, 3913(03) : 00212-9.
Abduo J. . .Assessing the fit of implant fixed prostheses: A critical review. International Journal of Oral and Maxillofacial Implants, 25(2010) : 506-515.
Karl M. . .In vitro study on passive fit in implant-supported 5-unit fixed partial dentures. International Journal of Oral and Maxillofacial Implants, 19(2004) : 30-37.
Katsoulis J. . .Misfit of implant prostheses and its impact on clinical outcomes: Definition, assessment and a systematic review of the literature. European Journal of Oral Implantology, 10(2017) : 121-138.
Kwan J.C.,Kwan J.C. . .The effects of a vertical compressive cyclic load on abutment screws and the stability of the prosthesis in nonengaging and partially engaging abutments in a screw-retained splinted fixed dental prosthesis. International Journal of Oral and Maxillofacial Implants, 37(2022) : 571-578.
Jemt T.,Lie A. . .Accuracy of implant-supported prostheses in the edentulous jaw: Analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique. ” Clinical Oral Implants Research, 6(1995) : 172-180.
Rutkunas V. .2022 .Misfit simulation on implant prostheses with different combinations of engaging and nonengaging titanium bases. Part 2: Screw resistance test. ” Journal of Prosthetic Dentistry, 04(2024) : 262-271.
Epprecht A. . .A strain gauge analysis comparing 4-unit veneered zirconium dioxide implant-borne fixed dental prosthesis on engaging and non-engaging abutments before and after torque application. ” Clinical and Experimental Dental Research, 4(2018) : 13-18.
Sakar D. .2023 .Effect of different implant locations and abutment types on stress and strain distribution under nonaxial loading: A 3-dimensional finite element analysis. ” Journal of Dental Sciences, 11(2024) : 607-613.
Choi S. . .Influence of implant-abutment connection biomechanics on biological response: A literature review on interfaces between implants and abutments of titanium and zirconia. ” Prosthesis, 5(2023) : 527-538.
Alzoubi F.M. . .Engaging Vs Non-engaging abutments: An in vitro study evaluating changes in microgap and screw morphology. Dentistry Journal, 12(2024) : 265.
Schoenbaum T.R. .2017 .The hemi-engaging fixed dental implant prosthesis: A technique for improved stability and handling. ” Journal of Prosthetic Dentistry, 09(2018) : 17-19.
Savignano R. . .Computational biomechanical analysis of engaging and nonengaging abutments for implant screwretained fixed dental prostheses. ” Journal of Prosthodontics, 30(2021) : 604-609.
Dogus S.M. .2011 .Effect of engaging abutment position in implant-borne, screw-retained three-unit fixed cantilevered prostheses. ” Journal of Prosthodontics, 00714(2011) : 1532-849X.
Alzoubi F.M. . .Evaluation of two implant-supported fixed partial denture abutment designs: Influence on screw surface characteristics. ” Journal of Prosthodontics, 33(2024) : 443-451.
Alzoubi F.M. .2022 .Preload evaluation of 2 implantsupported fixed partial denture abutment designs. ” Journal of Prosthetic Dentistry, 09(2022) : e1-1067.
Andrade G.S. .2023 .Biomechanics of implant-supported restorations. ” Brazilian Dental Science, 26(1) : .
Falcinelli C. .2023 .Finite element analysis in implant dentistry: State of the art and future directions. ” Dental Materials, 04(2023) : 539-556.
Cho S.Y. . .Three-dimensional finite element analysis on stress distribution of internal implant-abutment engagement features. International Journal of Oral and Maxillofacial Implants, 33(2018) : 319-327.
Akça K. . .A comparison of three-dimensional finite element stress analysis with in vitro strain gauge measurements on dental implants. International Journal of Prosthodontics, 15(2002) : 115-121.
Buzayan M.,Yunus N.B. . .Passive fit in screw retained multi-unit implant prosthesis understanding and achieving: A review of the literature. ” Journal of Indian Prosthodontic Society, 14(2014) : 16-23.
Rutkunas V. .2022 .Misfit simulation on implant prostheses with different combinations of engaging and nonengaging titanium bases. Part 1: Stereomicroscopic assessment of the active and passive fit. ” Journal of Prosthetic Dentistry, 04(2023) : 589-596.
Rutkunas V. .2024 .Misfit simulation on implant-supported prostheses with different combinations of engaging and nonengaging titanium bases: Part 3: A radiographic evaluation. ” Journal of Prosthetic Dentistry, 01 : .
Siamos G. .2002 .TRBIPA >2.3. ” Journal of Oral Implantology, 028 : 2-1336.
Vinhas A.S. . .In vitro study of preload loss in different implant abutment connection designs. ” Materials, 15(2022) : 1392.
Winkler S. .2003 .Implant screw mechanics and the settling effect: An overview. ” Journal of Oral Implantology, 29 : 242-245.
Sakaguchi R.L and S.E. Borgersen. .1995 .Nonlinear contact analysis of preload in dental implant screws. International Journal of Oral and Maxillofacial Implants, 10 : 295-302.
Shemtov-Yona K.,Rittel D. .2015 .An overview of the mechanical integrity of dental implants. , : 547384.
Theoharidou A. . .Abutment screw loosening in singleimplant restorations: A systematic review. International Journal of Oral and Maxillofacial Implants, 23(2008) : 681-690.
0

Citations

0

Downloads

14

Views