No Detail Found!

Assessment of Low-Dose Computed Tomography Protocols in Reducing Radiation Exposure without Compromising Diagnostic Yield in Pulmonary Nodule Detection

Author(s)
Amirah Fahad Alshammeri Department of Radiology, College of Medicine, University of Hail, Saudi Arabia
Abstract
Background: Pulmonary nodules are often the earliest radiological markers of lung cancer and their timely detection is essential for improving survival outcomes. While Computed Tomography (CT) remains the gold standard for nodule detection, concerns regarding cumulative radiation exposure have led to increasing use of Low-Dose Computed Tomography (LDCT). Objective: This study aimed to assess whether LDCT protocols can effectively reduce radiation exposure without compromising diagnostic yield in pulmonary nodule detection. Methodos: This cross-sectional analytical study was conducted in the Department of Radiology at Hail city from Jan 2025 to July 2025, including 75 patients aged =18 years who underwent CT chest for pulmonary nodule evaluation. Each patient received both standard-dose CT and LDCT protocols. Radiation dose was recorded in millisieverts (mSv) and two blinded radiologists independently reviewed the scans for presence, size and type of nodules. Standard-dose CT served as the reference standard. Results: The mean radiation dose for standard CT was 6.8±1.2 mSv, while LDCT reduced exposure to 1.9±0.5 mSv, representing a 72% dose reduction (p<0.001). Pulmonary nodules were identified in 41 patients (54.7%) on standard CT and in 39 patients (52.0%) on LDCT. The sensitivity, specificity, positive predictive value and negative predictive value of LDCT were 95.1, 94.1, 95.1 and 94.1%, respectively. LDCT successfully detected all clinically significant nodules =6 mm, though it missed two sub-5 mm ground-glass nodules. Interobserver agreement was excellent for both standard CT (? = 0.92) and LDCT (? = 0.89). Conclusion: LDCT significantly reduces radiation exposure while preserving high diagnostic accuracy in pulmonary nodule detection. Although its sensitivity for very small ground-glass nodules is slightly limited, LDCT demonstrates equivalent performance to standard CT for clinically relevant nodules, supporting its use in lung cancer screening and surveillance protocols.
Publication Details
Page(s) 204-208
DOI DOI not available
Published Journal: Journal of Pioneering Medical Sciences, Volume: 15, Issue: 2, Year: 2026

Request the full text from PASTIC

Keywords
Diagnostic accuracy, Low-Dose CT, Lung Cancer Screening, radiation exposure, Pulmonary Nodules
References
Wang J. .2025 .Deep learning reconstruction improves computer-aided pulmonary nodule detection and measurement accuracy for ultra-low-dose chest CT. ” BMC Medical Imaging, : .
Ding L. .2025 .Ultra-Low Dose Dual-Layer Detector Spectral CT for Pulmonary Nodule Screening: Image Quality and Diagnostic Performance. Insights into Imaging, : .
Chen L.G. .2025 .Hybrid iterative reconstruction in ultra-lowdose CT for accurate pulmonary nodule assessment: A phantom study. ” Medicine, : .
Zhou X. .2023 .Ultra-low-dose spectral-detector computed tomography for the accurate quantification of pulmonary nodules: An anthropomorphic chest phantom study. ” Diagnostic and Interventional Radiology, : .
Silberstein J. .2025 .Development of a 3D-printed chest phantom with simulation of lung nodules for studying ultralow-dose CT protocols. Applied Sciences, : .
Watanabe S. .2024 .Artifact reduction in low and ultra-low dose chest computed tomography. , : .
Chaudhary F.A. .2024 .Changes in complacency to adherence to COVID-19 preventive behavioral measures and mental health after COVID-19 vaccination among medical and dental healthcare professionals. ” Human Vaccines & Immunotherapeutics, 31 December, : .
Peters A.A. .2024 .Impact of artificial intelligence assistance on pulmonary nodule detection and localization in chest CT: A comparative study among radiologists of varying experience levels. ” Scientific Reports, : .
Revel M.P. .2025 .ESR essentials: Lung cancer screening with low-dose CT-Practice recommendations by the European society of thoracic imaging. ” European Radiology, : .
Snoeckx A. .2025 .Lung cancer screening with low-dose CT: Definition of positive, indeterminate and negative screen results. Nodule management recommendations from the European society of thoracic imaging. , : .
Pan Z. .2022 .Deep learning reconstruction shows better lung nodule detection for ultra-low-dose chest CT. , : .
Cheo H.M. .2025 .A systematic review of AI performance in lung cancer detection on CT thorax. ” BMC Medical Imaging, : .
'Regan O,P.W. O .2024 .Ultra-low-dose chest CT with modelbased iterative reconstruction versus standard dose for solid nodule analysis. World Journal of Radiology, : .
Ali S. .2023 .Impact of evaluation of Tumour grade by core needle biopsy on clinical risk assessment and patient selection for adjuvant systemic treatment in breast cancer. Pakistan Journal of Medical and Health Sciences, 15 March, : .
Ding L. .2025 .Ultra-low-dose dual-layer detector spectral CT for pulmonary nodule screening: Image quality and diagnostic performance. ” Insights into Imaging, : .
Pan Z.,dose CT .2024 .Systematic review. ” Clinical Radiology, : .
Zhou X. .2023 .Ultra-low-dose spectral-detector CT for accurate quantification of pulmonary nodules: Anthropomorphic chest phantom. ” Diagnostic and Interventional Radiology, : .
Jiang B. .2022 .Deep-learning image reconstruction improves lung nodule detection on ultra-low-dose chest CT. , : .
Zheng Z. .2024 .Clinical value of deep-learning image reconstruction versus ASIR-V: Nodule detectability and measurement on ultra-low-dose CT. ” Clinical Radiology, : .
Jo G.D. .2023 .Approximately 75% dose reduction with vendor-agnostic deep-learning image reconstruction while preserving nodule detectability. ” BMC Medical Imaging, : .
Wang J. .2025 .Deep-learning reconstruction improves CADe detection and volumetry on ultra-low-dose chest CT. ” BMC Medical Imaging, : .
Greffier J. .2025 .Impact of deep-learning image reconstruction on chest CT image quality at low dose. ” Physical and Engineering Sciences in Medicine, : .
0

Citations

0

Downloads

16

Views