No Detail Found!

New PVC Membrane-Based Ion-Selective Electrode for Ultrasensitive Detection of Bismuth(III) with Sudan I

Author(s)
Burak Aksar Graduate School of Natural and Applied Sciences, Van Yuzuncu Yil University, 65080, Van, Türkiye
Gulsah Saydan Kanberoglu Department of Chemistry, Faculty of Arts and Sciences, Erzincan Binali Yildirim University,24002, Erzincan,Türkiye
Fatih Coldur Department of Chemistry, Faculty of Arts and Sciences, Erzincan Binali Yildirim University,24002, Erzincan,Türkiye
Abstract
Summary: Accurate and dependable measurement of bismuth is vital for ensuring the safety of drugs, managing industrial processes, and evaluating environmental pollution. In this study, a new potentiometric sensor that uses Sudan I as the electroactive material within poly(vinyl chloride) (PVC) membrane structure was designed. The sensor displayed a broad linear concentration range of 1.0×103 to 1.0×10-10 M, an ultra-low detection limit of 4.0×10?11 M, and a response time of 30 seconds. It retained stable performance across a pH range of 2.0-7.0 and had an operational lifetime of about one month. When compared to existing literature, the sensor's selectivity and detection limit were significantly enhanced. It was successfully utilized to determine bismuth species in pharmaceutical formulations. Potentiometric methods provide clear advantages over other analytical techniques, such as simplicity, cost-effectiveness, quick response, and high selectivity. This developed sensor is a valuable tool for bismuth(III) determination, especially in quality control and pharmaceutical analysis.
Publication Details
Page(s) 414-421
Published Journal: Journal of Chemical Society of Pakistan, Volume: 47, Issue: 5, Year: 2025

Request the full text from PASTIC

Keywords
Bi(III)-selective sensor, pharmaceutical analysis, PVC membrane electrode, Ion-selective electrode, Potentiometric determination
References
Willhammar A. K.,Inge A. K.,Hinds T.,Ashktorab H.,Jagtap J.,Kim K. S.,Scott V. F.,Gastroenterol Am. J. .1999 .Metronidazole Therapy for Treating Helicobacter Pylori. , 94(955) : .
Cao T.,Shi X. L.,Li M.,Hu B.,Chen W.,Lyu W.,MacLeod J.,Chen Z. G.,(2023) N. R. A. Razak M. A. A.,Mohd Salleh N.,Saud R. M.,Said M. I. I. Ramli,Lead-Free Solder - A Short Review M. I. I. Ramli .2018 .. Advances in Bismuth-Telluride-Based Thermoelectric Devices: Progress and Challenges, 273(40) : 100122.
Glasgow G. P. .1991 .-18.. , 16(13) : .
Mesko M. F.,Novo D. L. R.,Costa V. C.,Henn and E. M. M. Flores A. S. .2020 .Toxic and Potentially Toxic Eelements Determination in Cosmetics Used for Make-up: A Critical Review. Anal. Chim. Acta, 1098(1) : .
Bakri F.,Gareso P. L.,Tahir D.,Protection D. .2024 .A Review the Role of Bismuth in X-ray. Radiat. Phys. Chem, 217(111510) : .
Lopez E.,Thorp S. C.,Mohan R. S.,Bismuth R. S. .2022 .Compounds as Catalysts in Organic Synthesis: A Mini Review. , 222(115765) : .
Meng Q.,Zhang X.,Li S.,Zhang Y.,Wu B.,Kang H. .2024 .Bismuth Oxyiodide Nanorods Towards Improvements in Fire Safety and Mechanical Properties of Natural Rubber, Polym. , 225(110770) : .
Biswas D.,Patra D.,Hota S. B.,A. Das N.,Modak R.,Mondal S.,Kabi S. .2025 .Influence of Bismuth Content on the Properties of GlassCeramics with Composition xBi2O3-(0. Thermal Analysis, and Dielectric Relaxation Process, Phys. B Condens. Matter, 697(416728) : 15ZnO-0.
Itoh S.-I.,Kaneco S.,Ohta K.,Mizuno T. .1999 .Determination of Bismuth in Environmental Samples with Mg-W Cell-Electrothermal Atomic Absorption Spectrometry. Anal. Chim. Acta, 379(169) : .
Acar O.,Kilic Z.,A. R Z. .1999 .Indium and Lead in Geological and Sea-water Samples by Electrothermal Atomic Absorption Spectrometry with Nickel-Containing Chemical Modifiers. Anal. Chim. Acta, 382(329) : .
J. L. Burguera M.,Burguera C.,Rivas C.,Rondon P.,Carrero M.,Gallignani M. .1999 .Determination of Bismuth in Biological Samples Using On-line Flow-Injection Microwave-Assisted Mineralization and Precipitation/Dissolution for Electrothermal Atomic Absorption Spectrometry. , 48(885) : .
Cankur O.,Ertaş N.,Ataman O. Y.,Anal J. .2002 .Determination of Bismuth Using On-line Preconcentration by Trapping on Resistively Heated W Coil and Hydride Generation Atomic Absorption Spectrometry. , 17(603) : .
Dobrowolski R.,Dobrzyńska J.,Gawrońska B. .2015 .Determination of Bismuth in Environmental Samples by Slurry Sampling Graphite Furnace Atomic Absorption Spectrometry Using Combined Chemical Modifiers, Environ. , 187(1) : .
Arslan Y.,Bakirdere S.,Titretir S.,Kendüzler E.,Ataman O. Y. .2009 .Determination and Interference Studies of Bismuth by Tungsten Trap Hydride Generation Atomic Absorption Spectrometry. , 80(127) : .
Ribeiro A. S.,Aurelio M.,Arruda Z.,Cadore S. .2002 .Determination of Bismuth in Metallurgical Materials Using a Quartz Tube Atomizer with Tungsten Coil and Flow Injection-Hydride-Generation Atomic Absorption Spectrometry, Spectrochim. Acta Part B, 57(2113) : .
J. Kobayashi H.,Terada H.,Sugiyama T.,Matsukawa M.,Chiba K.,Yokoyama K. .2011 .Determination of Bismuth in Environmental Samples by ICP-MS and Basic Examination of Cell Toxicity for Their Compounds. Bunseki Kagaku, 60(357) : .
Ye Z.,Lei Y.,Zeng X.,Tang Z.,Wang X.,Dai P.,Li X.,Chen L.,Hu K.,Ouyang D.,SSRN D. .2022 .Sensitive Determination of Bismuth in Human Plasma by ICP-MS and Its Application to Pharmacokinetic Study of Potassium Bismuth Citrate in Healthy Chinese Subjects. , : .
Afkhami A.,Madrakian T.,Siampour H. .2006 .Cloud Point Extraction Spectrophotometric Determination of Trace Quantities of Bismuth in Urine. J. Braz. Chem. Soc., 17(797) : .
Amin A. S. .2011 .Cloud-Point Extraction and Spectrophotometric Determination of Trace Quantities of Bismuth in Environmental Water and Biological Samples, Spectrosc. , 44(424) : .
Bagheban-Shahri F.,Niazi A. .2016 .Chemometrics-Enhanced Simultaneous Spectrophotometric Determination of Aluminum and Bismuth with Hematoxylin in Vegetables and Water Using Multivariate Calibration. , 6(137) : .
Barakat S. A.,Barakat S. A.,Chem Turkish J. .2002 .Flow Injection Extraction-Spectrophotometric Determination of Bismuth with Di-(hydrogenated tallow alkyl) Dimethylammonium Chloride. , 26(345) : .
Rastegarzadeh S.,Pourreza N.,Larki A. .2014 .Dispersive Liquid-Liquid Microextraction for the Microvolume Spectrophotometric Determination of Bismuth in Pharmaceutical and Human Serum Samples. Anal. Methods, 6(3500) : .
Sharma .2017 .Determination of Bismuth(III) in Environmental and Pharmaceutical Samples Using An Organic Reagent. Anal. Methods, 9(3682) : .
Chanawungmuang N.,Sukwattanasinitt M.,Rashatasakhon P. .2021 .Fluorescence Sensors for Bismuth (III) Ion from Pyreno[4,5-d]imidazole Derivatives, Photochem. , 97(301) : .
Tzanavaras G. Z.,Tsogas G. Z. .2022 .Development of a Paper-Based Analytical Method for the Selective Colorimetric Determination of Bismuth in Water Samples. , 10(265) : .
Montenegro D.,Satinský P.,Solich P.,Dachraoui O.,Atyaoui A.,Manaii F. .2004 .Colorimetric Bismuth Determination in Pharmaceuticals Using A Xylenol Orange SolGel Sensor Coupled to a Multicommutated Flow System. Anal. Chim. Acta, 504(235) : .
Maghraoui-Meherzi C.,Loukil C.,Estimation Uncertainty,Biochem J.,Okamoto Y.,Ara T. I. Fujiw,Notake H. .2001 .Determination of Bismuth in Nonferrous Alloys by Inductively Coupled Plasma Mass Spectrometry Combined with Use of SolidPhase Methylation and Electrothermal Vaporization Technique. , 55(514) : .
P.-J. Sun .1961 .Coxecutive Chelatometric Determination of Bismuth and Lead Using Gallein as Indicator. J. Chinese Chem. Soc., 8(314) : .
R. De Boeck F.,Adams J.,Hoste J.,Radioanal J. .1969 .Determination of Bismuth in Lead by Neutron Activation Analysis. , 109 : .
.2012 .. , 28(1353) : .
Hasdemir E.,Karaboduk K.,Tian S.,Huang L.,Gao Y.,Yua Z.,Tang D.,Acid-Based Magnetic Potentiometric Aptasensing A Nucleic .2023 .Platform for Indirect Detection of Prostate-Specific Antigen with Catalytic Hairpin Assembly, Sens. , 2(707) : .
Acta .2017 .. , 964(67) : .
Beyramabadi .2022 .Determination of Bismuth Ion in Biological and Water Samples with A Potentiometric Sensor Using Carbon Paste Electrode as A Straightforward and Simple Indicator Electrode. J. Iran. Chem. Soc, 19(3337) : .
Aglan R. F.,Hamed and H. M. Saleh M. M. .2023 .A New Screen-Printed Electrode for Selective Determination of Bismuth in Different Authentic Samples. J. Iran. Chem. Soc, 20(1481) : .
Deligonul N.,Bilgin S.,Gokce I.,Isildak O.,Green Fluorescent O. .2023 .-Multi Walled Carbon Nanotube Based Polymeric Membrane Electrode for Bismuth Ion Detection, Microchem. , 190(108710) : .
Buck R. P.,Lindner E. .1994 .Recomendations for Nomenclature of Ion-Selective Electrodes (IUPAC recommendations. Pure Appl., : .
.1994 .. , 66(2527) : .
Tohda S.,Amemiya S. .2000 .. Pure Appl. Chem, 72 : .
0

Citations

0

Downloads

16

Views