No Detail Found!

Reverse phase high performance liquid chromatographic-diode array detection method for quantification of rhein in microsample of rabbit plasma and application to the pharmacokinetic study

Author(s)
Asadullah Madni Faculty of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, 63100, Pakistan.
Muhammad Imran Khan Riphah Institute of Pharmaceutical Sciences, Riphah International University, Lahore, Pakistan.
Mubashar Rehman Department of Pharmacy, University of Central Punjab, Lahore. Pakistan
Nayab Tahir College of Pharmacy, University of Sargodha, Sargodha. Pakistan
Nadia Rai Faculty of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, 63100, Pakistan.
Farzana Parveen Faculty of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, 63100, Pakistan.
Muhammad Danish Saeed Faculty of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, 63100, Pakistan.
Muhammad Abdur Rahim Faculty of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, 63100, Pakistan.
Hassan Shah Faculty of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, 63100, Pakistan.
Abstract
Summary: The present work describes a reversed phase high-performance liquid chromatography (RP-HPLC) assay with diode array detection (DAD) for the determination of rhein, an active metabolite of diacerein, in spiked rabbit plasma. The plasma samples were subjected to one-step liquid-liquid extraction using a protein precipitating agent. The separation of rhein was achieved on an RP C18 hypersil-ODS column (250×4.6mm, 5µm). The mobile phase consisted of a binary mixture of methanol and water (15: 85 v/v, pH 4.7) run under the isocratic system at a flow rate of 1 ml.min-1, the wavelength of DAD was set at 210 nm. The method was validated for linearity, accuracy, precision, and stability according to the International Council for Harmonization (ICH guidelines). The calibration curve was linear over the range of 0.015-5 µg. ml-1 for rhein with the coefficient of regression (r2) of value 0.9980. Extraction recovery for rhein from rabbit plasma was in the range of 95.0% to 98.60% to different sample concentrations. The retention time of rhein was observed at 5.34 min. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 5 ng.ml-1 and 15 ng.ml-1 respectively. The assay method was successfully applied to the pharmacokinetic study of diacerein plain aqueous dispersion in albino rabbits.
Publication Details
Page(s) 866-874
Published Journal: Journal of Chemical Society of Pakistan, Volume: 42, Issue: 6, Year: 2020

Request the full text from PASTIC

Keywords
RP-HPLC, Validation, plasma, Rhein, method development
References
Esposito M.,Allarà R.,Verde S.,Cuzzocrea V.,Di Marzo .2015 .Diacerein is a potent and selective inhibitor of palmitoylethanolamide inactivation with analgesic activity in a rat model of acute inflammatory pain. Pharm. Res., 91(9) : .
Abdallah .2017 .Chitosan-coated diacerein nanosuspensions as a platform for enhancing bioavailability and lowering side effects: preparation, characterization, and ex vivo/in vivo evaluation. Int. J Nanomed, 4733 : .
Flores C.,Caixach J. .2015 .An integrated strategy for rapid and accurate determination of free and cell-bound microcystins and related peptides in natural blooms by liquid chromatographyelectrospray-high resolution mass spectrometry and matrix-assisted laser desorption/ionization time-of-flight/time-of-flight mass spectrometry using both positive and negative ionization modes. J. Chromat. A., 1407(76) : .
Chromat .1988 .. B: Biomed. Sci. and Appl., 428(173) : .
Nolin .2009 .Simultaneous analysis of multiple aminothiols in human plasma by high performance liquid chromatography with fluorescence detection. J. Chromat. B, 877(3274) : .
Fenner M. A.,Chakrabarty S.,Wang B.,Pagnotti V. S.,Hoang K.,Trimpin S.,McEwen C. N.,An LC .2017 .MS method providing improved sensitivity: electrospray ionization inlet. Anal. chem, 89(4798) : .
Xu B.,Li P.,G. Zhang, P.,Chromat P. .2015 .Comparative pharmacokinetics of puerarin, daidzin, baicalin, glycyrrhizic acid, liquiritin, berberine, palmatine and jateorhizine by liquid chromatography-mass spectrometry after oral administration of Gegenqinlian decoction and active components alignment (ACA) to rats. , 988(33) : .
Emam A. A.,Ali N. W. .2018 .Validated determination of diacerein and its active metabolite, rhein, by stability indicating constant pattern method as a novel manipulation of zero order spectra. Bull. Fac, 56(73) : .
Madni A.,Ahmad M.,Usman M.,M. M. Zubair M. Q.,Zaman H. M.,Shoaib A.,Munir S. A.,Khan M. N.,Amir M. S.,Qureshi M. S. .2010 .New High Performance liquid Chromatography Method for simultaneous Determination of Diclofenac and Meloxicam in Oral Formulation of Liposomes and Human Plasma. J. Chem. Soc. Pak, 32(654) : .
Madni A.,Ahmad M.,Naveed A.,Ashraf M.,Shuja Z. A. .2008 .An improved HPLC method for the determination of Ethionamide in Serum. J. Chem. Soc. Pak, 30(449) : .
.2013 .Guidance for Industry Bioanalytical Method Validation. , : .
M. Akhlaq G. M.,Khan S. U.,Jan A.,Wahab A.,Hussain A.,Nawaz H.,Abdelkader H. .2014 .A simple and rapid approach to evaluate the in vitro in vivo role of release controlling agent ethyl cellulose ether derivative polymer. Pak J Pharm Sci. 27, (6) : 1789.
Ritschel W. A.,Kearns G. L. .2009 .Handbook of Basic Pharmacokinetics including Clinical applications. , 432 : .
Yuksel N.,Bayindir Z. S.,Ozcelikay A. T. .2015 .In situ niosome forming maltodextrin proniosomes of candesartan cilexetil: In vitro and in vivo evaluations. Int. J. Biol. Macromol, 82(453) : .
Tang W. F.,Huang X.,Yu Q.,Qin F.,Wan M. H.,Liang M. Z. .2007 .Determination and pharmacokinetic comparison of rhein in rats after oral dosed with Da ChengQi decoction and Xiao‐Cheng‐Qi decoction. Biomed. Chrom, 21(1186) : .
Reuhs B. L.,Nielsen S.S. .2017 .High-Performance Liquid Chromatography, in Food Analysis. , 213 : .
Joubert P. H.,Rogers S. M. .2015 .ICH) and Other Guidelines, in Strategic Scientific and Medical Writing: The Road to Success. , 82 : .
Yaroshenko A. Y.,Khaimenov A.,Grigoriev A.,Sidorova A. .2014 .Determination of Rhein in blood plasma by HPLC with UV detection and its application to the study of bioequivalence. J. Anal. Chem, 69(793) : .
V. K. Yellepeddi J.,Radhakrishnan R.,Radhakrishnan R. .2018 .Penetration and anti‐inflammatory drugs in rat prostate tissue. The Prost, 78(80) : .
J.-H. Lee J. M.,Kim C.,Kim C. .2003 .Pharmacokinetic analysis of rhein in Rheum undulatum L. J. ethnopharm. 84, (5) : .
J. Liang S.,Hsiu P.,Wu P.,Chao P. .1995 .. Plan. med, 61(406) : .
0

Citations

0

Downloads

9

Views