No Detail Found!

Comparative investigation of daylight glare probability (DGP) comfort classes in clear sky condition

Author(s)
Juan Manuel Monteoliva INAHE, CONICET,Av. Ruiz Lean s/n Parque Gral. San Martín, CP 5500, Mendoza,Argentina
Julieta A. Yamín Garretón INAHE, CONICET,Av. Ruiz Lean s/n Parque Gral. San Martín, CP 5500, Mendoza,Argentina
Andrea E. Pattini INAHE, CONICET,Av. Ruiz Lean s/n Parque Gral. San Martín, CP 5500, Mendoza,Argentina
Abstract
Glare is considered one of the most important variables to reach visual comfort and visual quality. It represents one of the fundamental barriers for an effective use of daylighting in buildings. One of the best performing and robust glare prediction models, relative to other available metrics, is a Daylight Glare Probability (DGP). Based on a validated and precise methodology (RADIANCE) the aim of this work is to compare the DGP model (original cut-off values) with new cut-off values that differ according to the time of day (morning, noon and afternoon). Both cut-off values were compared at more than 300 simulated conditions of daylighting in an interior space. This work offers the originality of studying recently proposed cut-off values in climate luminous with predominant clear sky conditions. Currently, the application of these new cutoff values is reduced to the field of science or simulation professionals. The results showed important differences (64.86%) between the categories proposed by both cut-off values. Nevertheless, these differences do not have a significant impact in glare prediction (< 2.7%), in terms of glare absence (DGP <0.38) and presence (DGP >0.38). This analysis made it possible: (i) to regionally apply the main current corpus criteria regarding glare issues as well as emergent proposals and (ii) to present new experimental data aimed at helping the field and, together with other works, improving the tools used by professionals on a daily basis.
Publication Details
Page(s) 284-293
Published Journal: Journal of Daylighting, Volume: 8, Issue: 2, Year: 2021

Request the full text from PASTIC

Keywords
DGP, glare, Daylight, Clear sky
References
Figueiro M.G.,Rea M.S. .2010 .The effects of red and blue lights on circadian variations in cortisol, alpha amylase, and melatonin. Int J Endocrinol. Epub ahead of print 24 June, : .
Clear R.D. .2013 .Discomfort glare: What do we actually know?. Lighting Research and Technology, 45(2) : 141-158.
Kruisselbrink T.,Dangol R.,Rosemann A. .2018 .Photometric measurements of lighting quality: An overview. Building and Environment, 138 : 42-52.
Shin J.Y.,Yun G.Y.,Kim J.T. .2012 .Evaluation of Daylighting Effectiveness and Energy Saving Potentials of Light-Pipe Systems in Buildings. Indoor and Built Environment, 21(1) : 129-136.
M.B. Hirning G.L.,Isoardi I. Cowling. .2014 .Discomfort glare in open plan green buildings. Energy Build, 70 : 427-440.
Carlucci S.,Causone F.,De Rosa F.,Pagliano L. .2015 .A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design. Renew. Sustain. Energy Rev, 47 : 1016-1033.
Osterhaus W.K.E. .2005 .Discomfort glare assessment and prevention for daylight applications in office environments. Sol. Energy, 79 : 140-158.
CIE. .1983 .Discomfort glare in the interior working environment. , 55 : .
Shafavi N.S.,Zomorodian Z.S.,Tahsildoost M.,Javadi M.,M. M. .2020 .Occupants visual comfort assessments: A review of field studies and lab experiments. Solar Energy, 208 : 249-274.
Jakubiec J.A.,Reinhart C.F.,Wymelenberg Van Den K. .2015 .Towards an integrated framework for predicting visual comfort conditions from luminance-based metrics in perimeter daylit spaces. , : 2-9.
Konstantzos I.,Tzempelikos A. .2017 .Daylight glare evaluation with the sun in the field of view through window shades. Building and Environment, 113 : 65-67.
Suk J.Y. .2019 .Luminance and vertical eye illuminance thresholds for occupants' visual comfort in daylit office environments. Build. Environ, 148 : 107-115.
Wienold J.,Iwata T.,Khanie M. Sarey .2019 .Cross-validation and robustness of daylight glare metrics. Lighting Research & Technology, 51(7) : 983-1013.
Wienold J.,Christoffersen J. .2006 .Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras, Energy and buildings 38(7) (. , : 743-757.
Rodriguez R.G.,Garretón J.A.,A.E. Pattini. J.A. .2017 .An epidemiological approach to daylight discomfort glare. Building and Environment, 113 : 39-48.
Pierson C.,Wienold J.,Bodart M. .2017 .Discomfort glare perception in daylighting: influencing factors. Energy Procedia, 122 : 331-336.
Altomonte S.,Kent M.G.,Tregenza P.R.,Wilson R. .2016 .Visual task difficulty and temporal influences in glare response. Building and Environment, 95 : 209-226.
Kent M.G.,Altomonte S.,Tregenza P.R.,Wilson R. .2015 .Discomfort glare and time of day. Lighting Research and Technology, 47(6) : 641-657.
Osterhaus W.K.E.,Bailey I.L. .1992 .Large area glare sources and their effect on visual discomfort and visual performance at computer workstations. , : 1825-1829.
Yamin J.,Pattini A.,Colombo E. .2020 .e329. Informes de La Construcción, 72(557) : .
Bian Y.,Dai Q.,Ma Y. .2020 .Variable set points of glare control strategy for side-lit spaces: Daylight glare tolerance by time of day. Solar Energy, 201 : 268-278.
Mangkuto R.A.,Kurnia K.A.,Azizah D.N.,Atmodipoero R.T.,Soelami F.X.N. .2017 .Determination of discomfort glare criteria for daylit space in Indonesia, Sol. Energy, 149 : 151-163.
Yamin J.,Garretón J.,Rodriguez R.G.,Ruiz A.,Pattini A.E. .2015 .Degree of eye opening: A new discomfort glare indicator. Building and Environment, 88 : 142-150.
Europe Norms .2018 .Blinds and shutters. Thermal and visual comfort. Performance characteristics and classification, : .
Molina G.,Vera S.,Bustamante W.,Bleicher T. .2008 .. , : .
Ward G. .1994 .. Computer Graphics, in: Proceedings of '94 SIGGRAPH Conference, : .
Berardi U.,Wang T. .2014 .Daylighting in an atrium-type high performance house. Building and Environment, 76 : 92-104.
Fontoynont M. .1999 .Daylight Performance of Buildings. Lyon: ENTPE, : .
J.M. Monteoliva A.,Villalba A.,Pattini A. .2015 .Variability in dynamic daylight simulation in clear sky conditions according to selected weather file: Satellite data and land-based station data. Lighting Research & Technology, 49 : 508-520.
Reinhart C.F.,Voss K. .2003 .Monitoring manual control of electric lighting and blinds. Light. Res. Technol, 35(3) : 243-260.
Ward G.L.,Shakespeare R.A. .2007 .. Revised edition, : .
Jakubiec J.A.,Reinhart C.F. .2012 .The 'adaptive zone' - A concept for assessing glare throughout daylit spaces. Lighting Research and Technology, 44 : 149-170.
Wienold J. .2004 .Evalglare: A new Radiance-based tool to evaluate glare in office spaces. in: 3rd International Radiance Workshop, : .
Suk J.,Schiler M. .2013 .Investigation of Evalglare software, daylight glare probability and high dynamic range imaging for daylight glare analysis. Light. Res. Technol, 45 : 450-463.
0

Citations

0

Downloads

9

Views