No Detail Found!

Optimal window to wall ratio ranges of photovoltachromic windows in high-rise office buildings of Iran

Author(s)
Soheil Fathi Department of Architectural Engineering, Faculty of Engineering, Razi University,Kermanshah,Iran
Allahbakhsh Kavoosi Department of Architectural Engineering, Faculty of Engineering, Razi University,Kermanshah,Iran
Abstract
Windows are one of the weakest building components concerning high thermal losses. Traditional windows cannot adapt to external and internal environmental conditions. On the other hand, smart windows such as electrochromic (EC) windows do not emit greenhouse gases and adapt to environmental conditions and increase indoor environmental quality. The combination of EC windows and building integrated photovoltaic system (BIPV) is called photovoltachromic (PVC) windows. This paper aims to find optimal window to wall ratio (WWR) ranges of PVC windows in a high-rise office building model in four different cities in Iran. This paper uses several simulations to find the optimal WWR ranges of PVC windows using Radiance and EnergyPlus. First, the minimum acceptable WWR value in each climate condition was identified using several simulations without any optimization tools. Afterward, traditional windows were replaced with EC windows and results indicated that energy consumption of the building reduced up to 15.94%. In the next stage, BIPV was combined with EC windows, and results indicated that BIPV reduced energy consumption of the building up to 7.55%. Finally, simulation results showed that PVC windows reduced energy consumption of the building up to 16.31% in Kermanshah, 19.69% in Tehran, 18.59% in Yazd and 17.36% in Bandar Abbas. Also, the optimal WWR range of PVC windows in Kermanshah was 80-90%, while it was 70-80% in Tehran, Yazd and Bandar Abbas. Simulation results indicated that cooling degree days (CDD) of the site, where buildings were located, effected on the optimal WWR range of PVC windows in high-rise office buildings. An analytical approach was used to validate simulation results, and it showed that simulation results had 1.60-6.22% error.
Publication Details
Page(s) 134-148
Published Journal: Journal of Daylighting, Volume: 8, Issue: 1, Year: 2021

Request the full text from PASTIC

Keywords
Electrochromic smart windows, window-to-wall ratio, Building integrated photovoltaic, High-rise building
References
Granqvist C.G.,Niklasson G.A. .2018 .Electrochromics on a roll: Web-coating and lamination for smart windows. Surf. Coatings Technol, 336 : 133-138.
R.C.G.M. Loonen F.,Favoino J.L.M.,Hensen M.,Overend M. .2017 .Review of current status, requirements and opportunities for building performance simulation of adaptive facades. J. Build. Perform. Simul, 10 : 205-223.
Gorgolis G.,Karamanis D. .2016 .Solar energy materials for glazing technologies. Sol. Energy Mater. Sol. Cells, 144 : 559-578.
Granqvist C.G. .2014 .Electrochromics for smart windows: Oxide-based thin films and devices. Thin Solid Films, 564 : 1-38.
Aguilar-Santana J.L.,Jarimi H.,Velasco-Carrasco M.,Riffat S.,Low-Carbon Technol S. .2020 .Review on window-glazing technologies and future prospects, Int. , 15 : 112-120.
Goncalves J.E.,Hooff D.,Saelens D. .2020 .A physics-based high-resolution BIPV model for building performance simulations. Sol. Energy, 204 : 585-599.
Res Energy .2018 .. , 12 : 178-194.
Aguacil S.,Lufkin S. .2019 .Active surfaces selection method for building-integrated photovoltaics (BIPV) in renovation projects based on self-consumption and self-sufficiency, Energy Build. , 193 : 15-28.
.2020 .. , 10 : 2337.
Ghosh A. .2020 .Potential of building integrated and attached/applied photovoltaic (BIPV/BAPV) for adaptive less energy-hungry building's skin: A comprehensive review. J. Clean. Prod, 276 : 123343.
Roy A.,Ghosh A.,Bhandari S. .2020 .Perovskite Solar Cells for BIPV Application: A Review. , 10 : 129.
Fang Y.,Hyde T.,Hewitt N.,Eames P.C.,B. Norton, P.C. .2010 .Thermal performance analysis of an electrochromic vacuum glazing with low emittance coatings. Sol. Energy, 84 : 516-525.
DeForest N.,Shehabi A.,J. O'Donnell G.,Garcia J.,Greenblatt E.S.,Lee S.,Selkowitz D.J.,Milliron D.J. . .United States energy and CO2 savings potential from deployment of near-infrared electrochromic window glazings. , : .
.2015 .. , 89 : 107-117.
Aldawoud A. .2013 .Conventional fixed shading devices in comparison to an electrochromic glazing system in hot, dry climate. Energy Build, 59 : 104-110.
Lee J. Hoon,Jeong J.,Tae Chae Y. .2020 .Optimal control parameter for electrochromic glazing operation in commercial buildings under different climatic conditions. Appl. Energy, 260 : 114338.
Öztop .2020 .Analysis of cooling load on commercial building in UAE climate using building integrated photovoltaic façade system. Sol. Energy, 199 : 617-629.
Qiu C.,Yang H.,W. Zhang, H. .2019 .Investigation on the energy performance of a novel semi-transparent BIPV system integrated with vacuum glazing. Build. Simul, 12 : 29-39.
Abdelhakim M.,Kandar M.Z.,Lim Y.W. .2019 .Experimental investigation of overall energy performance in Algerian office building integrated photovoltaic window under semi-arid climate. Journal of Daylighting, 6 : 23-41.
J.-J. Wu ,M.-D. Hsieh W.-P.,Liao J.-S.,Chen J.-S. .2009 .Fast-Switching Photovoltachromic Cells with Tunable Transmittance. ACS Nano, 3 : 2297-2303.
Malara F.,Cannavale A.,Carallo S. .2014 .Smart Windows for Building Integration: A New Architecture for Photovoltachromic Devices. ACS Appl. Mater. Interfaces, 6 : 9290-9297.
Cannavale A.,Eperon G.E.,Cossari P.,Abate A.,Snaith H.J. .2015 .Perovskite photovoltachromic cells for building integration. Energy Environ. Sci. 8, : 1578-1584.
Favoino F.,Fiorito F.,Cannavale A.,Overend M. .2016 .Optimal control and performance of photovoltachromic switchable glazing for building integration in temperate climates. Appl. Energy, 178 : 943-961.
Pierucci A.,Cannavale A.,Martellotta F.,Fiorito F. .2018 .Smart windows for carbon neutral buildings: A life cycle approach. , 165 : 160-171.
Cannavale A.,Manca M.,Malara F.,Cingolani R. .2011 .Highly efficient smart photovoltachromic devices with tailored electrolyte composition. Energy Environ. Sci. 4, : 2567-2574.
Ayoosu M.I.,Lim Y.-W.,Leng P.C.,Idowu O.M. .2021 .Daylighting Evaluation and Optimisation of Window to Wall Ratio for Lecture Theatre in the Tropical Climate. Journal of Daylighting, 8 : 20-35.
Wen L.,Hiyama K.,Koganei M. .2017 .A method for creating maps of recommended window-to-wall ratios to assign appropriate default values in design performance modeling: A case study of a typical office building in Japan, Energy Build. , 145 : 304-317.
Marino C.,Nucara A.,Pietrafesa M. .2017 .Does window-to-wall ratio have a significant effect on the energy consumption of buildings? A parametric analysis in Italian climate conditions. J. Build. Eng, 13 : 169-183.
Chi F.,Wang Y.,Wang R.,Li G.,Peng C. .2020 .An investigation of optimal window-to-wall ratio based on changes in building orientations for traditional dwellings. Sol. Energy, 195 : 64-81.
Xue P.,Li Q.,Xie J.,Zhao M. .2019 .Optimization of window-to-wall ratio with sunshades in China low latitude region considering daylighting and energy saving requirements. Appl. Energy, 233 : 62-70.
Goia F. .2016 .Search for the optimal window-to-wall ratio in office buildings in different European climates and the implications on total energy saving potential. Sol. Energy, 132 : 467-492.
Pino A.,Bustamante W.,Escobar R.,Pino F.E. .2012 .Thermal and lighting behavior of office buildings in Santiago of Chile, Energy Build. , 47 : 441-449.
Yeom S.,Kim H.,Hong T.,Lee M. .2020 .Determining the optimal window size of office buildings considering the workers' task performance and the building's energy consumption. Build. Environ, 177 : 106872.
Phillips R.,Troup L.,Fannon D.,Eckelman M.J. .2020 .Triple bottom line sustainability assessment of window-to-wall ratio in US office buildings. Build. Environ, 182 : 107057.
.2020 .. , 208 : 493-514.
Urbano Gutiérrez R.,Du J.,Ferreira N.,Ferrero A.,Sharples S. .2019 .Daylight control and performance in office buildings using a novel ceramic louvre system. Build. Environ, 151 : 54-74.
Xuan Q.,Li G.,Lu Y.,Zhao B.,Zhao X.,G. X. .2019 .Pei, Daylighting characteristics and experimental validation of a novel concentrating photovoltaic/daylighting system. Sol. Energy, 186 : 264-276.
.2007 .. , 81 : 1166-1179.
Chi F.,Wang R.,Li G.,Xu L.,Wang Y.,Peng C. .2020 .Integration of suntracking shading panels into window system towards maximum energy saving and non-glare daylighting. Appl. Energy, 260 : 114304.
Teixeira H.,Gomes M.G.,Rodrigues A. Moret,Pereira J. .2020 .Thermal and visual comfort, energy use and environmental performance of glazing systems with solar control films. Build. Environ, 168 : 106474.
Karlsson J.,Roos A. .2000 .Angle-resolved optical characterisation of an electrochromic device. Sol. Energy, 68 : 493-497.
Piccolo A.,Pennisi A.,F. Simone, A. .2009 .Daylighting performance of an electrochromic window in a small scale test-cell, Sol. , 83 : 832-844.
Wu Y.,Wang T.,Lee E.S.,Kämpf J.H.,Scartezzini J.-L. .2019 .Split-pane electrochromic window control based on an embedded photometric device with real-time daylighting computing. Build. Environ, 161 : 106229.
Cannavale A.,Fiorito F.,Resta D. .2013 .Visual comfort assessment of smart photovoltachromic windows. Energy Build, 65 : 137-145.
Neufert E.,St E. .1980 .Architects' data, 2d (international. , : .
Joseph De Chiara Martin Zelnik J.P. .2001 .Time-saver standards for interior design and space planning, Second edition. , : .
. .. , : .
Engineering Construction,Organization Construction .2009 .. National Building Code of Iran No.3, : .
.2009 .. National Building Code of Iran No.14, : .
N.B.C. .2009 .. , 13 : .
N.B.C. of I ,Engineering Construction,Organization Construction .2009 .. , (4) : .
.2009 .. National Building Code of Iran No.15, : .
.2009 .. National Building Code of Iran No.19, : .
Elotefy H.,Abdelmagid K.S.S.,Ahmed T.M.F. .2015 .Energyefficient Tall Buildings Design Strategies: A Holistic Approach. , 74 : 1358-1369.
Shafavi N.S.,Tahsildoost M.,Zomorodian Z.S. .2020 .Investigation of illuminance-based metrics in predicting occupants' visual comfort (case study: Architecture design studios. Sol. Energy, 197 : 111-125.
Korsavi S.S.,Zomorodian Z.S.,Tahsildoost M. .2016 .Visual comfort assessment of daylit and sunlit areas: A longitudinal field survey in classrooms in Kashan, Iran, Energy Build. , 128 : 305-318.
Luo Z.,Sun C.,Dong Q. .2020 .A daylight-linked shading strategy for automated blinds based on model-based control and Radial Basis Function (RBF) optimization. Build. Environ, 177 : 106854.
Clean .2018 .. , 174 : 1204-1214.
Fathalian A.,Kargarsharifabad H. .2018 .Actual validation of energy simulation and investigation of energy management strategies (Case Study: An office building in Semnan, Iran). Case Stud. Therm. Eng, 12 : 510-516.
Mateus N.M.,Pinto A. .2014 .da Graça, Validation of EnergyPlus thermal simulation of a double skin naturally and mechanically ventilated test cell. Energy Build, 75 : 511-522.
Therm J. .2009 .. , 48 : 85-95.
Haghighat nejad ,Build Energy .2021 .Energy performance of building integrated photovoltaic high-rise building: Case study. , 235 : 110707.
0

Citations

0

Downloads

16

Views