No Detail Found!

Appraisal of the Visual Environment in an Industrial Factory: a Case Study in Subtropical Climates

Author(s)
Kieu Pham School of Design, Creative Industries, Queensland University of Technology,,Australia
Veronica Garcia-Hansen School of Design, Creative Industries, Queensland University of Technology,,Australia
Gillian Isoardi School of Design, Creative Industries, Queensland University of Technology,,Australia
Abstract
The physiological and psychological benefits of daylighting for office occupants have been well explored. Current research usually focuses on visual comfort in office buildings. However, there is limited knowledge about daylight quality in industrial work environments. In Australia, most industrial buildings are built from standard factory structures that employ daylight from skylights and large door openings, with little consideration to daylighting design strategies and visual comfort. In bright sky conditions as those present in Australia, large openings can become a source of visual discomfort. It is important to understand how workers perceive the luminous environment in this type of work setting. This research explored the perception of daylighting in an industrial work environment. Qualitative measures (questionnaires, interviews, and observational mapping) and quantitative measures (physical data) were collected over a four week period to examine the type of visual comfort perceived by industrial workers. The results suggests that the desirability to have windows and to have access to a view were important features in this work setting. Access for task lighting and reports of uneven daylighting were indicative to the varying levels of illuminance under intermediate sky conditions. This was reflected in the daylight glare index results and comparisons to the background luminance and glare source luminance, indicating that adaptation may be the cause of responses to daylighting being uneven. The results suggests a need for further research into the quality of the luminous environment in industrial work settings.
Publication Details
Page(s) 12-26
Published Journal: Journal of Daylighting, Volume: 3, Issue: 2, Year: 2016

Request the full text from PASTIC

Keywords
Visual Comfort, Luminance mapping, Illuminance, Daylighting
References
Gou Z.,Lau S. S.-Y.,Qian F. .2013 .Comparison of mood and task performance in naturally-lit and artificially-lit environments. Indoor and Built Environment, 24 : .
Webb A. R. .2006 .Considerations for lighting in the built environment: Nonvisual effects of light. Energy and Buildings, 38 : 721-727.
Wang N.,Boubekri M. .2010 .Design recommendations based on cognitive, mood and preference assessments in a sunlit workspace. Lighting Research and Technology, 43 : 55-72.
Hwang T.,Kim J. Tai .2011 .Effects of Indoor Lighting on Occupants' Visual Comfort and Eye Health in a Green Building. Indoor and Built Environment, 20 : 75-90.
Fontoynont M. .2002 .Perceived performance of daylighting systems: lighting efficacy and agreeableness. Solar Energy, 73 : 83-94.
W. van Bommel and G. van den Beld .2004 .Lighting for work: a review of visual and biological effects. Lighting Research and Technology, 36 : 255-269.
J.B. de Boer D.,Fischer D. .1978 .. , : .
Meek C.,Wymelenberg K. V. D. .2014 .. , : .
Knez I.,Kers C. .2000 .. Age on Mood and Cognitive Performance, Environment and Behavior, 32 : 817-831.
Küller R.,Ballal S.,Laike T.,Mikellides B.,G. Tonello, B. .2006 .The impact of light and colour on psychological mood: a cross-cultural study of indoor work environments. Ergonomics, 49 : 1496-1507.
Boubekri M.,Hull R. B.,Boyer L. L. .1991 .Impact of Window Size and Sunlight Penetration on Office Workers' Mood and Satisfaction: A Novel Way of Assessing Sunlight. Environment and Behavior, 23 : 474-493.
Leather P.,Pyrgas M.,Beale D.,Lawrence C. .1998 .. Environment and Behavior, 30 : 739-762.
M. B. C. Aries J. A.,Veitch G. R.,Newsham G. R. .2010 .office characteristics predict physical and psychological discomfort. Journal of Environmental Psychology, 30 : 533-541.
Ne'Eman E.,Hopkinson R. G. .1970 .Critical minimum acceptable window size: a study of window design and provision of a view. Lighting Research and Technology, 2 : 17-27.
Wotton E.,Barkow B. .1983 .An investigation of the effects of windows and lighting in offices. in: Proceedings of the International Daylighting Conference, : 405-11.
Butler and P. M. Biner D. L.,Individuals D. L. .1987 .Variability among Settings, Behaviors, and. Environment and Behavior, 19 : 695-721.
Escuyer S.,Fontoynont M. .2001 .Testing in situ of automatic ambient lighting plus manually controlled task lighting: office occupant reactions. in: Proceedings of the 9th European Lighting Conference, : 70-75.
Veitch J. A.,M. G. M. Stokkermans G. R.,Newsham G. R. .2011 .. Environment and Behavior, 45 : 198-214.
NIELSEN R. .1987 .Evaluation of metabolism from heart rate in industrial work. Ergonomics, 30 : 563-572.
Hétu R. .1994 .Mismatches between Auditory Demands and Capacities in the Industrial Work Environment. International Journal of Audiology, 33 : 1-14.
Kivimäki M.,Leino-Arjas P.,Luukkonen R.,Riihimäki H.,Vahtera J.,Kirjonen J. .2002 .. Work Stress And Risk Of Cardiovascular Mortality: Prospective Cohort Study Of Industrial Employees, British Medical Journal, 325 : 857-60.
Hammig O.,Bauer G. F. .2013 .-life conflict and health in an industrial work environment. Occupational Medicine, 64 : 34-38.
Drury J. .1981 .Factories: planning, design and modernisation. , : .
Lyons S. L. .1981 .. , : .
Kuchta M. J. .1994 .Daylighting in American industrial architecture: Three investigations. , : .
Lee J. .2015 .. Smart Factory Systems, Informatik Spektrum, 38 : 230-235.
Skinner J.S. .1997 .Form and Fancy: factories and factory buildings by Wallis. Gilbert & Partners, : .
Robbins C. L. .1986 .Daylighting: design and analysis. , : .
Boyce P. R. .2003 .Human factors in lighting. , : .
Clear R. .2012 .Discomfort glare: What do we actually know?. Lighting Research and Technology, 45 : 141-158.
.1983 .. , : .
Rodriguez R. G.,Pattini A. .2012 .Effects of a Large Area Glare Source in Cognitive Efficiency and Effectiveness in Visual Display Terminal Work. , 8 : 283-299.
Houser K. W. .2012 .A Glaring Omission. , 9 : 5-7.
B. Van Wanrooy. ,S. Oxenbridge. ,J. Buchanan. ,Jakubauskas M. .2007 .. The Benchmark Report Workplace Research, : .
Wang D.,Groat L. N.,I. ebrary L. N. .2013 .. , : .
Hugge S.,Lofberg H. A. .1999 .Post occupancy evaluation of daylight in buildings: a report of. IEA SHC Task 21 / ECBCS Annex 29 International Energy Agency (IEA), : .
Energy International,Agency International .1999 .Post occupancy evaulation of daylight in buildings. , : .
Steemers. K.,N. Baker. K.,Fanchiotti A. .1993 .Daylighting in architecture: a European reference book. James & James, : .
Australia Standards . .. 1997; AS/NZS 1680.2, : 4-1997.
Newsham G.,Veitch J. .2001 .Lighting quality recommendations for VDT offices: a new method of derivation. Lighting Research and Technology, 33 : 97-113.
.1989 .Chartered Institution of Building Services Engineers, Lighting guide the industrial environment. Chartered Institution of Building Services Engineers, : .
.1986 .. The Commission, : .
Garcia Hansen V.,Hirning M.,Bell J. M. .2012 .An assessment tool for selection of appropriate daylighting solutions for buildings in tropical and subtropical regions: validation using radiance simulation. World Renewable Energy Forum (WREF), : 3600-3608.
Tuaycharoen N.,Tregenza P. R. .2007 .View and discomfort glare from windows. Lighting Research and Technology, 39 : 185-200.
M. B. Hirning G. L.,Isoardi and I. Cowling .2014 .Discomfort glare in open plan green buildings. Energy and Buildings, 70 : 427-440.
Wienold J.,Christoffersen J. .2006 .Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras. Energy and Buildings, 38 : 743-757.
J. M. Waldram .1953 .The Design of the Visual Field, National Illumination Committee of Great Britain. , : .
Ferwerda J.,Pattanaik S.,Shirley P. .1996 .A model of visual adaptation for realistic image synthesis. , : .
W. K. E. Osterhaus and I. L.,Bailey and I. L. .1992 .Large area glare sources and their effect on visual discomfort and visual performance at computer workstations. , : 1825-9.
Parpairi K.,Baker N.,Steemers K.,Compagnon R. .2002 .The Luminance Differences index: a new indicator of user preferences in daylit spaces. Lighting Research and Technology, 34 : 53-68.
Speed R. .2005 .The Effect of Adaptation Levels and Daylight Glare on Office Workers' Perception of Lighting Quality in Open Plan Offices. Architectural Science Review, 48 : 229-237.
Osterhaus W. .2009 .Design Guidelines for Glare-Free Daylit Work Environments. , : .
Christoffersenn J.,Johnson. K.,E. Petersen. K.,Valbjorn O.,Hygge S.,Kingdom United .2000 .Windows and daylight: a post-occupancy evaluation of Danish offices. in: Lighting 2000 Proceedings of the CIBSE/ILE Joint Conference, : 112-20.
0

Citations

0

Downloads

11

Views