No Detail Found!

To assess the co-relation between corrected qt interval prolongation and abnormal scan during vasodilator nuclear stress test

Author(s)
Kaleem Ullah Sheikh Liaquat National Hospital and Medical College,Karachi,Pakistan
Abeer Sarfaraz Liaquat National Hospital and Medical College,Karachi,Pakistan
Sana Sarfaraz Department of Pharmacology, Faculty of Pharmacy & Pharmaceutical Sciences, University of Karachi,Karachi,Pakistan
Amna Farooq Liaquat National Hospital and Medical College,Karachi,Pakistan
Rabia Munawwar Department of Pharmacology, Jinnah Sindh Medical University,Karachi,Pakistan
Mohad Aamir Dow International Medical College,Karachi,Pakistan
Abstract
In the detection of coronary heart diseases amongst the non-invasive techniques the role of myocardial perfusion imaging is indexed. The rationale of this study was to compare the different parameters and the association between the exercise MPI and vasodilator MPI in the detection of coronary artery disease (that is prolonged Qt interval with the size of perfusion defects). It was a cross-sectional prospective study with purposive non-probability sampling technique which was conducted in a tertiary care hospital from January 2020 to June 2020 for a period of 6 months. All patients regardless of gender were included in this study and age ranging from 30 to 80 years with comorbidities ranging from diabetes, hypertension and smokers were also included. A total of 100 patients were included in this study out of which 81% were male, 50% were diabetics, 69% were hypertensive, 39% had a history of coronary artery disease, 25% were smokers and 63% had hyperlipidemia. For statistical analysis SPSS 21 was applied and significant association was observed between DTS treadmill score and the perfusion defect in vasodilator MPI, corrected Qt interval and DTS tread mill score and between corrected Qt and size of the perfusion defect (P value < 0.001). It was thus seen that the different components of the noninvasive nuclear stress test tend to co-relate and thus aid in the detection of coronary artery disease increasing the accuracy of results.
Publication Details
Page(s) 417-421
Published Journal: Pakistan Journal of Pharmaceutical Sciences, Volume: 34, Issue: S1, Year: 2021

Request the full text from PASTIC

Keywords
vasodilator, Coronary artery disease, nuclear stress test, QT interval
References
Allschwilerstrasse 10 . .. , : .
Azarbal B,Hayes SW,Lewin HC,Hachamovitch R,Cohen I,Berman DS .2004 .The incremental prognostic value of percentage of heart rate reserve achieved over myocardial perfusion single-photon emission computed tomography in the prediction of cardiac death and all-cause mortality: Superiority over 85% of maximal age-predicted heart rate. J. Am. Coll. Cardiol., 44(2) : 423-430.
Chaturvedi V,Bhargava B .2007 .Health Care Delivery for Coronary Heart Disease in India- Where Are We Headed? Am. , 5(1) : 32-37.
Eslami V,Safi M,Taherkhani M,Adibi A,Movahed MR .2013 .QT dispersion and T wave peak to end time significantly change after primary percutaneous coronary intervention in patients with acute ST elevation. In: Cardiology, 125 : 228-228.
George SK,Waly HM,Abdul Moteleb MT .2015 .Assessment of QT dispersion in patients with acute STEMI receiving thrombolytic versus those performing primary percutaneous coronary intervention (PCI) therapy. , 83 : 1023-1030.
Gunaydın ZY,Bektaş O,Gurel YE,Karagoz A,Kaya A,Kırış T,Zeren G .2016 .The value of the Duke treadmill score in predicting the presence and severity of coronary artery disease. Kardiologia Polska Polish Heart J., 74(2) : 127-134.
Gussak I,Antzelevitch C,Wilde ADAM,Powell B,Ackerman M,Shen W .2008 .Electrical diseases of the heart. Genetics, mechanisms, treatment, prevention. , : 520.
Helmy H,Abdel-Galeel A,Kishk YT,Sleem KM,Egypt Heart J .2017 .Correlation of corrected QT dispersion with the severity of coronary artery disease detected by SYNTAX score in non-diabetic patients with STEMI. , 69(2) : 111-117.
Ikonomidis I,Athanassopoulos G,Karatasakis G,Manolis AS,Marinou M,Economou A,Cokkinos DV .2000 .Dispersion of ventricular repolarization is determined by the presence of myocardial viability in patients with old myocardial infarction. A dobutamine stress echocardiography study. Eur. Heart J., 21(6) : 446-456.
Islam MS,Mondal SK,Jahan J,Arefin M,Ahmed N,Das PR,Azam MG .2020 .Effect of PCI on QTC Dispersion in Patients with Angina. Univ. Heart J., 16(1) : 33-39.
Jensen CJ,Lusebrink S,Wolf A,Schlosser T,Nassenstein K,Naber CK,Bruder O .2015 .Reduction of QTDA Novel Marker of Successful Reperfusion in NSTEMI. Pathophysiologic Insights by CMR. Int. J. Med, 12(5) : 378.
Kenigsberg DN,Khanal S,Kowalski M,Krishnan SC M .2007 .Prolongation of the QTc interval is seen uniformly during early transmural ischemia. J. Am. Coll. Cardiol., 49(12) : 1299-1305.
Kosmala W,Przewlocka-Kosmala M,Halawa B M .2004 .QT dispersion and myocardial viability in patients after acute myocardial infarction. Int. J. Cardiol., 94(2-3) : 249-254.
Matsumoto N and Hirayama A .2016 .Clinical value of high duke treadmill score with myocardial perfusion SPECT. , : 1301-1303.
Monitillo F,Leone M,Rizzo C,Passantino A,Iacoviello M .2016 .Ventricular repolarization measures for arrhythmic risk stratification. World J. Cardiol., 8(1) : 57-73.
Morise AP,Beto R,Gupta N,Gunel E .2000 .Exercise QT dispersion as an independent predictor of the presence of ischemia on myocardial perfusion imaging. ANE, 5(3) : 240-247.
Nabati M,Dehghan Z,Kalantari B,Yazdani J .2018 .Corrected QT Interval Prolongations in Patients with non-ST-Elevation Acute Coronary Syndrome. , 13(4) : 173.
Nowinski K,Jensen S,Lundahl G,Bergfeldt L G .2000 .Changes in ventricular repolarization during percutaneous transluminal coronary angioplasty in humans assessed by QT interval, QT dispersion and T vector loop morphology. J. Intern. Med, 248(2) : 126-136.
Ornek E,Duran M,Ornek D,Demircelik BM,Murat S,Kurtul A,Cetin Z A .2014 .The effect of thrombolytic therapy on QT dispersion in acute myocardial infarction and its role in the prediction of reperfusion arrhythmias. Niger J Clin Pract, 17(2) : 183-187.
Pekdemir M,Karaca I,Cevik Y,Yanturali S,Ilkay E .2006 .The diagnostic value of QT dispersion for acute coronary syndrome in patients presenting with chest pain and nondiagnostic initial electro-cardiograms. Mt. Sinai J. Med, 73(5) : 813-817.
Postema PG,Wilde AAM .2014 .The measurement of the QT interval. Curr. Cardiol. Rev., 10(3) : 287-294.
Rodriguez-Jimenez AE,Cruz-Inerarity H,Negrin-Valdes T,Fardales-Rodriguez R,Chavez-Gonzalez E .2019 .Corrected QT-interval dispersion: An electrocardiographic tool to predict recurrence of myocardial infarction. MEDICC Review, 21 : 22-28.
Shaikh AH,Hanif B,Hassan K B .2011 .Correlation of Duke's treadmill score with gated myocardial perfusion imaging in patients referred for chest pain evaluation. JPMA, 61(8) : 723.
Shawl FA,Velasco CE,Goldbaum TS,Forman MB .1990 .Effect of coronary angioplasty on electrocardiographic changes in patients with unstable angina secondary to left anterior descending coronary artery disease. J. Am. Coll. Cardiol., 16(2) : 325-331.
Stankovic I,Putnikovic B,Janicijevic A,Jankovic M,Cvjetan R,Pavlovic S,Neskovic AN .2015 .Myocardial mechanical and QTc dispersion for the detection of significant coronary artery disease. Eur. Heart J.: Cardiovasc. Imaging, 16(9) : 1015-1022.
Van Dongen IM,Kolk MZ,Elias J,Meijborg VM,Coronel R,de Bakker JM,Henriques JP JM .2018 .The effect of revascularization of a chronic total coronary occlusion on electrocardiographic variables. A sub-study of the EXPLORE trial. J. ElectroCardiol., 51(5) : 906-912.
0

Citations

0

Downloads

8

Views