No Detail Found!

Frequency of Accurate Working Length Measurement Using Endo Motor Having Built in Apex Locator Compared to Periapical Radiograph

Author(s)
Ambreen Azad Department of Operative Dentistry and Endodontics, Ibn-e-Siena Hospital and Research Institute Multan, Pakistan
Qurat Ul Ain Department of Operative Dentistry and Endodontics, Ibn-e-Siena Hospital and Research Institute Multan, Pakistan
Sheeza Manan Department of Operative Dentistry and Endodontics, Ibn-e-Siena Hospital and Research Institute Multan, Pakistan
Sharina Naz Department of Operative Dentistry and Endodontics, Ibn-e-Siena Hospital and Research Institute Multan, Pakistan
Mustafa Sajid Department of Operative Dentistry and Endodontics, Ibn-e-Siena Hospital and Research Institute Multan, Pakistan
Assad Jamil Department of Operative Dentistry and Endodontics, Ibn-e-Siena Hospital and Research Institute Multan, Pakistan
Abstract
OBJECTIVE: To determine the accuracy of apex locator in determination of working length of root canals during endodontics compared to periapical radiographs in cases with irreversible pulpitis. METHODOLOGY: This cross-sectional study was conducted at Operative Dentistry Department of Ibn-e-Siena Hospital Multan over a period of 6-months from 1st January 2023 to 30th June 2023. Patients 12 - 35 years of age, either male or female gender presenting with irreversible pulpitis of maxillary anterior teeth and planned to undergo root canal treatment were consecutively included in the study. Pre-operative working length was determined through intraoral radiograph using standardized paralleling technique. Per operatively, the working length was taken with an endo-motor with built-in apex locator in dual mode using stainless steel K file # 10 or #15. Working length (in mm) was considered accurate if the apex locator reading lied 0-2mm short of the radiographic working length. Descriptive statistics were run, and stratified comparison were made using chi-square test at 5% significance level. RESULTS: The mean age of the participants was 23.9 ± 6.8 years and 50.3% (n=79) were females. Incisors were involved in 64.3% (n=101) of patients. The mean working length on periapical radiograph and on apex locator was 21.5 ± 1.8 mm and 20.6 ± 1.5 mm respectively. The apex locator was 84.1% (n=132) accurate in measuring the working length compared to periapical radiograph. CONCLUSION: Compared with periapical radiography, the apex locator demonstrated high accuracy not affected by age, gender of the patients and type of tooth involved.
Publication Details
Page(s) 40-44
Published Journal: Journal of Pakistan Dental Association, Volume: 34, Issue: 2, Year: 2025

Request the full text from PASTIC

Keywords
Root canal treatment, Irreversible pulpitis, Periapical radiograph, Working length, Apex locator
References
Cushley S,Duncan HF,Lappin MJ,Chua P,Elamin AD,Clarke M. . .. , : .
.2021 .Efficacy of direct pulp capping for management of cariously exposed pulps in permanent teeth: a systematic review and meta-analysis. Int Endod J, 54 : 556-71.
. .. , : .
Khadse A,Shenoi P,Kokane V,Khode R .2017 .Electronic Apex Locators-An overview. Indian J Conserv Endod, 2 : 35-40.
Jarad FD,Albadri S,Gamble C,Burnside G,Fox K,Ashley JR .2011 .Working length determination in general dental practice: a randomised controlled trial. Br Dent J, 211 : 595-8.
Lekshmy DS,Deepthi PR,Ganesh C,Chacko G,Abhilash A,Satheesh S,Weiger A,Lost R,C. R .2011 .The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length. , 1052 : .
J Endod .2002 .. , 28 : 116-9.
Fouad AF,Rivera EM,Krell KV .1993 .Accuracy of the endex with variations in canal irrigants and formane size. J Endod, 19 : 63-7.
Cianconi L,Angotti V,Felici R,Conte G,Mancini M. .2010 .Accuracy of three electronic apex locators compared with digital radiography: an ex vivo study. J Endod, 36(06) : 2003-7.
Hassanien EE,Hashem A,Chalfin H .2010 .Histomorphometric study of the root apex of mandibular premolar teeth: an attempt to correlate working length measured with electronic and radiograph methods to various anatomic positions in the apical portion of the canal. J Endod., 08 : .
Hoer D,Attin T. .2004 .The accuracy of electronic working length determination. Int Endod J, 37 : 125-31.
QaziI HS,Maxood A,Abdullah S. .2004 .Comparison of radiographic and electronic working length in anterior teeth. Pak Oral Dent J., 00764 : 2885.
Dummer PM,McGinn JH,Rees DG . .The position and topography of the apical canal constriction and apical foramen. Int Endod J., : .
.2011 .Comparative role of radiographs and electronic apex locator in working length determination. Pak Oral Dent J, 31 : 185-8.
Akisue E,Gratieri SD,Barletta FB,Caldeira CL,GrazziotinSoares R .2014 .Not all electronic foramen locators are accurate in teeth with enlarged apical foramina: an in vitro comparison of 5 brands. J Endod, 40 : 109-12.
Chhabra A,Prathap BS,Ramya KP,Yadav P,Mehra H,Parvathy SJ .2024 .Comparative assessment of working length determination: apex locators versus endomotor with built-in apex locator in single-rooted permanent teeth. J Pharm Bioallied Sci, 16(Suppl 3) : S2892-4.
Mousavi SA,Zahedinejad A,Kowsari B,Kolahdouzan E,Mousavi SI,Saeidian S .2021 .Comparative evaluation of root canal working length determination with three methods: conventional radiography, digital radiography and raypex6 apex locator: an experimental study. J Dent Mater Tech, 10 : 87-93.
.2021 .. , 55126 : .
0

Citations

0

Downloads

60

Views