No Detail Found!

In-Vitro Marginal Fit of 3D-Printed vs Milled Provisional Crowns

Author(s)
Reem Mohsen AlMutairi Department of Restorative Dental Sciences and Prosthodontics, College of Dentistry, Majmaah University, AlMajmaah, Saudi Arabia
Abstract
Introduction: Provisional crowns are essential intermediate restorations in fixed prosthodontics, and marginal fit is a key determinant of periodontal health, pulpal protection, and long-term clinical success. Present CAD/CAM technologies allow for production by subtractive milling or additive manufacturing, each with inherent technical properties potentially influencing marginal fit. Comparative in-vitro evidence under controlled conditions, however is still limited in this regard, and controlled assessments have to be applied to inform fabrication method choice. Methods: The laboratorybased experimental setup was used to compare the marginal fit of provisional crowns produced through digital CAD design followed by fabrication through 3D printing (n = 10) or milling (n = 10). Both the groups used a standardized tooth preparation and master die. All the crowns were produced from PMMA-based materials following the manufacturer's suggested parameters. Marginal gap was measured at four standardized positions on each crown, mid-buccal, mid-lingual, mid-mesial, and mid-distal, using a 50× magnification stereomicroscope. The data were 40 measurements per group. The data were tested for normality and compared using independent samples t-tests with the significance level at p<0.05. Intraand inter-examiner reliability were also tested using intraclass correlation coefficients (ICCs). Results: The group mean marginal gap in the 3D-printed cohort was 95.8±8.5 µm, whereas the milled cohort had a mean of 73.1±7.0 µm. The mean difference recorded between the cohorts was 22.7 µm, the difference that was statistically significant (t = 8.56, p<0.001), with a substantial effect size (Cohen's d = 1.92). Site-specific tests also revealed that at all four marginal sites measured, the milled crowns had consistently smaller gaps, with p-values of less than 0.001 for all the tests. Intraclass correlation coefficients (ICCs) for intra- and inter-examiner measurements were greater than 0.97, reflecting excellent measurement reliability. Qualitative synthesis revealed that the crowns 3D-printed showed slightly greater variability at the marginal areas, which was generally because of small differences in junction surface smoothness, whereas the milled crowns showed more uniform adaptation. Conclusion: Within the constraints of this in vitro investigation, milled provisional crowns exhibited significantly reduced marginal discrepancies with improved fit uniformity over their 3D-printed counterparts. Both techniques yielded results within clinical acceptable margins, demonstrating, however, that although milling may be more suited, 3D printing is also a useful alternative if manufacturing efficiency or material usage is the priority.
Publication Details
Page(s) 176-180
Published Journal: Journal of Pioneering Medical Sciences, Volume: 14, Issue: S2, Year: 2025

Request the full text from PASTIC

Keywords
Additive Manufacturing, Marginal fit, 3D printing, Milling, CAD/CAM, In-vitro study, Provisional Crowns, PMMA, Subtractive Manufacturing
References
Sidhom M. .2022 ."Effect of different CAD/CAM milling and 3D printing digital fabrication techniques on the accuracy of PMMA working models and vertical marginal fit of PMMA provisional dental prosthesis: An in vitro study. " Polymers, : .
Mohajeri M.,milling. M. .2021 ."Marginal fit of temporary restorations fabricated by the conventional chairside method, 3D printing, and. , : 7236.
Igret ̦,A. ̦ .2023 ."Marginal fit of milled versus different 3Dprinted materials for provisional fixed dental prostheses: An in-vitro comparative study. " Medical and Pharmaceutical Reports, : .
Morón-Conejo B. .2024 ."Fit comparison of interim crowns manufactured with open software/open hardware workflows (3D-printed vs milled. " Journal of Esthetic and Restorative Dentistry, : .
Al-Dulaijan Y.A. .2024 ."Internal and marginal fits of 3Dprinted provisional prostheses: Comparative effect of different printing parameters. " Frontiers in Oral Health, 1491984 : .
Merchant A. .2025 ."Comparison of marginal fit between milled and three-dimensional printed polymethylmethacrylate prostheses for single crowns, anterior bridges, and pier-abutment bridges: An in-vitro study. " Journal of the Indian Prosthodontic Society, 40 : 24.
Yılmaz B.K. .2025 ."Micro-CT evaluation of marginal and internal fit of provisional fixed dental prostheses fabricated by subtractive and additive manufacturing: An in-vitro study. " BMC Oral Health, : .
Aktaş N. .2025 ."Marginal and internal adaptation of milled and 3D-printed crowns for primary molars: An in-vitro micro-CT comparison. " BMC Oral Health, : .
Kumar R. .2021 ."An in-vitro evaluation of 3D-printed provisional restoration with different finish line designs versus CAD/CAM-milled: Marginal fit assessment.". International Journal of Prosthodontics and Restorative Dentistry, 10019 : .
Othman A. .2023 ."The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study.". PLOS ONE, 0285760(9) : .
Al-Wadei M.H.D. .2022 ."Marginal adaptation and internal fit of 3D-printed provisional crowns and fixed dental prosthesis resins compared to CAD/CAM-milled and conventional provisional resins: A systematic review and meta-analysis. " Coatings, : .
Hasanzade M. . .Comparison of the marginal and internal fit of PMMA interim crowns printed with different layer thicknesses in 3D-printing technique. ” Clinical and Experimental Dental Research, 10(2023) : 758-839.
Abad-Coronel C. .2023 ."Fracture resistance comparative analysis of milled-derived vs. 3D-printed CAD/CAM materials for single-unit restorations.". Polymers (Basel), : .
Wu J. .2021 ."Evaluation of internal fit and marginal adaptation of provisional crowns fabricated with three different techniques. " Sensors, 740(3) : .
Chaturvedi S. . ."Marginal and internal fit of provisional crowns fabricated using 3D printing technology. " Technology and Health Care, 28(2020) : 635-642.
Giannetti L. .2021 ."The occlusal precision of milled versus printed provisional crowns. " Journal of Dentistry, 103924 : .
Morón-Conejo B. .2024 ."Fit comparison of interim crowns manufactured with open and proprietary 3D printing modes versus milling technology: An in vitro study. " Journal of Esthetic and Restorative Dentistry, 36(12) : 1693-1703.
Jain S. .2022 ."Physical and mechanical properties of 3Dprinted provisional crowns and fixed dental prosthesis resins compared to CAD/CAM milled and conventional provisional resins: A systematic review and meta-analysis. " Polymers, 2691(13) : .
Banna El,H.I. El .2024 ."Evaluation of internal fit and marginal adaptation of 3D-printed versus CAD/CAM milled provisional anterior crowns: An in-vitro study." Egyptian Dental Journal. , 317500(2024) : 3721-3731.
Aktaş N. .2025 ."Marginal and internal adaptation and absolute marginal discrepancy of 3D-printed, milled, and prefabricated crowns for primary molar teeth: An in vitro comparative study." BMC Oral Health. , 575(1) : .
Haggag M.M. .2024 ."Effect of two fabrication techniques (CAD/CAM and 3D printing) on the internal fit, marginal adaptation and fracture resistance of multiple fused provisional restorations: An in vitro study. " Advanced Dental Journal, 318520(2024) : 853-864.
Shenoy A. . ."An in vitro comparison of the marginal fit of provisional crowns using the virtual tooth preparation workflow against the traditional technique. " Journal of the Indian Prosthodontic Society, 273(2023) : 23-397.
Mohajeri M. .2021 ."Marginal fit of temporary restorations fabricated by the conventional chairside method, 3D printing, and milling." Frontiers in Dentistry. , 31 : 7236.
Galbraith A. .2025 ."Evaluation of color stability and marginal integrity in provisional restorations: A study of milling, 3D printing, and conventional fabrication methods.". Dentistry Journal, 10(5) : .
Ahmed B.M. .2023 ."3D evaluation of marginal fit of interim crowns fabricated using conventional, virtual and three-dimensional printed working dies: An in vitro study. " Journal of Fundamental and Clinical Research, 221188(2023) : 170-189.
Kumar R. . ."An in vitro evaluation of 3D-printed provisional restoration marginal adaptation on diverse finish lines.". International Journal of Prosthodontics and Restorative Dentistry, 10019(2021) : 82-87.
Alqahtani A.S. .2023 ."Efficacy of 3D-printing additive manufacturing in comparison to CAD-CAM, and conventional method for fabrication of interim crowns: A systematic review and meta-analysis. " Journal of Biomaterials and Tissue Engineering, 3347(12) : 1101-1115.
0

Citations

0

Downloads

134

Views