Microhardness and Microleakage Assessment of a Newly Formulated Hydrophilic Nano-Sealant and a Flowable Nano-Composite: An In Vitro Study

Author(s)
Jennifer Buela Peter Department of Public Health Dentistry, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai -77, Tamil Nadu, India
Jayashri Prabakar Department of Public Health Dentistry, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai -77, Tamil Nadu, India
Ganesh J. Department of Pedodontics & Preventive Dentistry, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai -77, Tamil Nadu, India
Rajesh Kumar Shanmugam Department of Pedodontics & Preventive Dentistry, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai -77, Tamil Nadu, India
Meignana Arumugham Department of Public Health Dentistry, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai -77, Tamil Nadu, India
Abstract
Objectives: This study evaluated and compared the microhardness and microleakage performance of a newly formulated hydrophilic nano-sealant, a commercially available hydrophilic sealant (UltraSeal XT Hydro) and a formulated flowable nano-composite under thermocycling conditions. Methods: Sixty extracted human mandibular third molars were randomly allocated into three groups (n = 20 each). Group I: newly formulated hydrophilic nano-sealant; Group II: UltraSeal XT Hydro sealant; Group III: formulated flowable nano-composite. Occlusal surfaces were etched with 37% phosphoric acid for 20 s, rinsed, dried according to material specifications and the assigned material applied and light-cured for 20 s. All specimens underwent 1500 thermocycles between 5°C and 55°C. Microleakage was evaluated using 0.5% basic fuchsin dye penetration and confocal laser scanning microscopy, scored using Overbo and Raadal's criteria. Microhardness was measured on the cured surface using the Vickers hardness test with a 200 g load for 20 s. Data were analyzed using the Kruskal-Wallis and Chi-square tests; median (IQR) values are reported for non-parametric data. Results: Group I (new hydrophilic nanosealant) showed the lowest median micro-leakage score (0.5 [0-1.0]), significantly lower than Group III (flowable composite) (p = 0.032). Micro-hardness was highest in Group II (median 15.1 [14.5-15.6] VHN) and lowest in Group III (10.1 [9.6-10.8] VHN); differences did not reach statistical significance (p = 0.061). Conclusion: The newly formulated hydrophilic nanosealant demonstrated superior microleakage resistance compared to the formulated flowable nano-composite, while microhardness differences among materials were not statistically significant. Further in vivo studies with defined material compositions and larger samples are required before clinical recommendations can be made.
Publication Details
Page(s) 80-84
Published Journal: Journal of Pioneering Medical Sciences, Volume: 14, Issue: S2, Year: 2025

Request the full text from PASTIC

Keywords
Nanotechnology, Dental restoratives, Microleakage Prevention, Surface Properties
References
Kumaraguru M. .1810 ."Oral health status of school-going children aged 12-15 years in Tiruvallur district, Tamil Nadua cross-sectional study." South Eastern European Journal of Public Health. , 10 : 677-683.
Rakshitha V.S.,December V.S. .2024 ."Comparative evaluation of microhardness of hydrophilic sealant and flowable composite on permanent molars: an in vitro study. " Journal of Pioneering Medical Sciences, 13(7) : .
Mehta S.,April 2023 . ."Evaluation of neo-implant abutment junction sealing gel among Indian patients. " Bioinformation, 19(4) : 502.
Nair V.,December V. .2024 ."Assessment of dye penetration and penetration depth of hydrophilic sealant and flowable composite. " Journal of Pioneering Medical Sciences, 13(7) : .
Gajewski V.E. .2012 ."Monomers used in resin composites: degree of conversion, mechanical properties and water sorption/solubility." Brazilian Dental Journal. , 23 : 508-514.
Güçlü Z.A. . ."Characterisation and microleakage of a new hydrophilic fissure sealant: UltraSeal XT hydro. " Journal of Applied Oral Science, 24(2016) : 344-351.
Hu Y.T. .2021 ."The antibacterial effect and physical performance of pit and fissure sealants based on an antibacterial core-shell nanocomposite. " Journal of the Mechanical Behavior of Biomedical Materials, 117 : .
Lai C.C.,December C.C. .2022 ."Development of antibacterial composite resin containing chitosan/fluoride microparticles as pit and fissure sealant to prevent caries. " Journal of Oral Microbiology, 14(1) : .
Fernandes K.S.,April 2012 . ."A comparison between three different pit and fissure sealants with regard to marginal integrity. " Journal of Conservative Dentistry and Endodontics, 15(2) : 146-150.
Sengar E.V et .2022 ."Comparative evaluation of microleakage of flowable composite resin using etch and rinse, self-etch adhesive systems and self-adhesive flowable composite resin in Class V cavities: confocal laser microscopic study. " Materials, 15 : 4963.
AlJefri G.H. .2022 ."Penetration and adaptation of the highly viscous zinc-reinforced glass ionomer cement on contaminated fissures: an in vitro study with SEM analysis.". International Journal of Environmental Research and Public Health, 19(10) : 6291.
Mallineni S.K.,March 2023 . ."Silver nanoparticles in dental applications: a descriptive review. " Bioengineering, 10(3) : 327.