Incidence of Iodinated Contrast Media Reaction: A Multicentre Study in Computed Tomography

Author(s)
Areej Amir University Institute of Radiation Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, The University of Lahore,,Pakistan
Syed Muhammad Yousaf Farooq University Institute of Radiation Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, The University of Lahore,,Pakistan
Babar Ali University Institute of Radiation Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, The University of Lahore,,Pakistan
Wajeeha Tariq University Institute of Radiation Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, The University of Lahore,,Pakistan
Muhammad Zakir University Institute of Radiation Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, The University of Lahore,,Pakistan
Rimsha Ajmal University Institute of Radiation Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, The University of Lahore,,Pakistan
Khadija Rasool University Institute of Radiation Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, The University of Lahore,,Pakistan
Saqib Mehmood University Institute of Radiation Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, The University of Lahore,,Pakistan
Aitezaz Hussain Department of Radiology Sciences & Medical Imaging Technology, Faculty of Allied Health Sciences, Superior University,Lahore,Pakistan
Maham Nazir Rashid Latif Medical College, Bachelor of Medicine and Bachelor of Surgery,Lahore,Pakistan
Abstract
Contrast enhanced Computed Tomography (CECT) plays a great role in investigating any clinical condition, because of its high sensitivity. But with this comes the problem of contrast reactions have risen over last years, representing an important concern. To find the incidence of iodinated contrast media reactions on Computed Tomography in different centers in a particular region. This was descriptive multicenter study conducted in radiology departments of University of Lahore Teaching hospital, Services hospital and Sheikh Zayed hospital, Lahore. This study included the entire in and out patients advised CT with contrast and both genders of all age. The collected data was entered and analyzed with the help of SSPS version 24 and Microsoft Excel. In our study, total 227 patients were included out of which 105 were females and 122 were males. 9.7% experienced mild reaction with no cases of moderate and severe reaction. Mild reactions were more common in females (12.4%) than males (7.4%). Most common symptoms observed were nausea (4.8%), vomiting (3.1%), and shivering (1.8%). Contrast reactions resulted is mostly mild and more proportion of mild reactions are found among females than males. No cases of severe reactions are identified in the patients.
Publication Details
Page(s) 29-34
DOI DOI not available
Published Journal: Bioscience Research, Volume: 21, Issue: 1, Year: 2024

Request the full text from PASTIC

Keywords
adverse reactions, Iodinated contrast media, Non-Immediate Reactions, High Osmolality Contrast Media, Acute Adverse Reactions, Hypersentivity Reactions, Immediate Reactions, Low Osmolality Contrast Media
References
Caimmi S.,Benyahia B.,Suau D.,Bousquet‐Rouanet L.,Caimmi D.,Bousquet P. J.,Allergy E. .2010 .Clinical value of negative skin tests to iodinated contrast media. , 40(5) : 805-810.
Cha M. J.,Kang D. Y.,Lee W.,Yoon S. H.,Choi Y. H.,Byun J. S.,Cho B. S. J. R. .2019 .Hypersensitivity reactions to iodinated contrast media: a multicenter study of 196 081 patients. , 293(1) : 117-124.
Cochran S. T.,Bomyea K.,Sayre J. W. J. A. J. o. R. .2001 .Trends in adverse events after IV administration of contrast media. , 176(6) : 1385-1388.
Cohan R. H.,Bullard M. A.,Ellis J. H.,Jan S. C.,Francis I. R.,Garner W. L.,Dunnick N. R. J. A. r. .1997 .Local reactions after injection of iodinated contrast material: detection, management, and outcome. , 4(11) : 711-718.
Davenport M. S.,Perazella M. A.,Yee J.,Dillman J. R.,Fine D.,McDonald R. J.,Weinreb J. C. J. R. .2020 .Use of intravenous iodinated contrast media in patients with kidney disease: consensus statements from the American College of Radiology and the National Kidney Foundation. , 294(3) : 660-668.
Dillman J. R.,Trout A. T.,Davenport M. S. J. P. .2018 .Allergic-like contrast media reaction Amir et al. management in children. 48, : 1688-1694.
Doña I.,Bogas G.,Salas M.,Testera A.,Moreno E.,Laguna J. J.,Torres M. J. J. F. i. P. .2020 .Hypersensitivity reactions to multiple iodinated contrast media. , 11 : 575437.
Faucon A.-L.,Bobrie G.,Clément O. J. E. J. o. R. .2019 .Nephrotoxicity of iodinated contrast media: From pathophysiology to prevention strategies. , 116 : 231-241.
Kobayashi D.,Takahashi O.,Ueda T.,Deshpande G. A.,Arioka H.,Fukui T. J. B. M. I.,Making D. .2013 .Risk factors for adverse reactions from contrast agents for computed tomography. , 13(1) : 6.
Lell M. M.,Wildberger J. E.,Alkadhi H.,Damilakis J.,Kachelriess M. J. I. r. .2015 .Evolution in computed tomography: the battle for speed and dose. , 50(9) : 629-644.
Nucera E.,Parrinello G.,Gangemi S.,Buonomo A.,Aruanno A.,Lohmeyer F. M.,Rizzi A. J. B. .2022 .Contrast medium hypersensitivity: a large Italian study with long-term follow-up. , 10(4) : 759.
Park H. J.,Son J. H.,Kim J. H.,Kang M. K.,Han K.,Kim E. H.,Park S. H. J. R. .2019 .Relationship between lower dose and injection speed of iodinated contrast material for CT and acute hypersensitivity reactions: an observational study. , 293(3) : 565-572.
Shehadi W. H. J. A. J. o. R. .1975 .Adverse reactions to intravascularly administered contrast media: a comprehensive study based on a prospective survey. , 124(1) : 145-152.
Singh J.,Daftary A. J. J. o. n. m. t. .2008 .Iodinated contrast media and their adverse reactions. , 36(2) : 69-74.
Sohn ,Kim ,Lee ,Kim ,Cho J.-K.,Kang H.-R. J. E. R. .2019 .Immediate and delayed hypersensitivity after intraarterial injection of iodinated contrast media: a prospective study in patients with coronary angiography. , 29 : 5314-5321.
Zhang B.,Dong Y.,Liang L.,Lian Z.,Liu J.,Luo X.,S. J. M. X. .2016 .The incidence, classification, and management of acute adverse reactions to the low-osmolar iodinated contrast media Isovue and Ultravist in contrast-enhanced computed tomography scanning. , 95(12) : .
0

Citations

0

Downloads

37

Views