No Detail Found!

Intra-ocular pressure reduction in primary congenital glaucoma patients undergoing Ahmed glaucoma valve implant

Author(s)
Mahtab Mengal Departments of Ophthalmology, Helpers Eye Hospital, Quetta Pakistan
Madiha Waseem Dr Ruth K M Pfau Civil Hospital, Karachi, Pakistan
Rabia Chaudhry Jinnah Postgraduate Medical Center, Karachi Pakistan
Syed Muhammad Saad POB Hospital, Karachi – Pakistan
Abstract
Objective: To evaluate the intra ocular pressure reduction in congenital glaucoma patients undergoing Ahmed glaucoma (AG) valve implant. Methodology: This descriptive case - series was conducted in the department of ophthalmology, Jinnah Postgraduate Medical Center, Karachi from November 2020 to November 2021. There were 58 eyes of 41 patients with corneal diameter >12mm in any meridian and IOP = 20. AG valve was implanted. Postoperatively, intra ocular pressure was recorded at 18month. Surgery was considered significant if IOP reduction was >20% from base line. Results: The average age of the children was 10.16 ± 8.74 months. IOP reduction was observed in 85.37% (35/41) cases. Common complications observed in this study were pupillary irregularities, tube endothelial touch, fibrous growth, cataract, endophthalmitis and implant extrusion. Conclusion: Intraocular pressure was reduced in con-genital glaucoma patients undergoing AG valve implan-tation. Hence it can be recommended as preferred surgical treatment for congenital glaucoma.
Publication Details
Page(s) 423-426
DOI DOI not available
Published Journal: Rawal Medical Journal, Volume: 50, Issue: 2, Year: 2025

Request the full text from PASTIC

Keywords
Congenital glaucoma, Ahmed glaucoma valve, intra ocular pressure.
References
Ling C,Zhang D,Zhang J,Sun H,Du Q,Li X. .2020 .Updates on the molecular genetics of primary congenital glaucoma (Review). Exp Ther Med, 20 : 968-77.
Damji KF,Yaseen A,Mahar PS .2023 .Tackling Blindness from the Scourge of Glaucoma. Pak J Ophthalmol, 39 : 75-7.
Ou Y,Yu F,Law SK,Coleman AL,Caprioli J .2009 .Outcomes of Ahmed glaucoma valve implantation in children with primary congenital glaucoma. Arch Ophthalmol, 127 : 1436-41.
Allison K,Patel D,Alabi O .2020 .Epidemiology of Glaucoma: The Past, Present, and Predictions for the Future. Cureus, 12 : e11686.
Mahar PS .2018 .Role of OCT in Diagnosis and Progression of Glaucoma. Pak J Ophthalmol, 34 : 207-20.
Pirouzian A,Demer JL. .2008 .Clinical findings following Ahmed Glaucoma Valve implantation in pediatric glaucoma. Clin Ophthalmol, 2 : 123-7.
Kanski JJ .2020 .Kanski's clinical ophthalmology : a systematic approach. , : .
Badawi AH,Al-Muhaylib AA,Al Owaifeer AM,Al-Essa RS,Al-Shahwan SA .2019 .Primary congenital glaucoma: An updated review. Saudi J Ophthalmol, 33 : 382-8.
Englert JA,Freedman SF,Cox TA .1999 .The Ahmed valve in refractory pediatric glaucoma. Am J Ophthalmol, 127 : 34-42.
Kiage DO,Gradin D,Gichuhi S,Damji KF .2009 .Ahmed glaucoma valve implant: experience in East Africa. Middle East Afr J Ophthalmol, 16 : 151-5.
Liu B,Huang W,He M,Zheng Y. .2007 .An investigation on the causes of blindness and low vision of students in blind school in Guangzhou]. Yan ke xue bao. Eye Sci, 23 : 117-20.
Ben-Zion I,Tomkins O,Moore DB,Helveston EM .2011 .Surgical results in the management of advanced primary congenital glaucoma in a rural pediatric population. Ophthalmology, 118 : 231-5.
Mandal AK,Chakrabarti D,Gothwal VK .2023 .Approach to primary congenital glaucoma: A perspective. Taiwan J Ophthalmol, 13 : 403-4.
Al-Hazmi A,Awad A,Zwaan J,Al-Mesfer SA,Al-Jadaan I,Al-Mohammed A .2005 .Correlation between surgical success rate and severity of congenital glaucoma. Br J Ophthalmol, 89 : 449-53.
Mandal AK .2022 .Illuminated Microcatheter Passage Assisted Circumferential Trabeculotomy and Trabeculectomy (IMPACTT): An improved surgical procedure for Primary Congenital Glaucoma. Semin Ophthalmol, 37 : 786-9.
Beck AD,Freedman S,Kammer J,Jin J .2003 .Aqueous shunt devices compared with trabeculectomy with Mitomycin-C for children in the first two years of life. Am J Ophthalmol, 136 : 994-1000.
Senthil S,Turaga K,Mohammed HA,Krishnamurthy R,Badakere S,Dikshit S .2018 .Outcomes of Silicone Ahmed Glaucoma Valve Implantation in Refractory Pediatric Glaucoma. J Glaucoma, 27 : 769-75.
Yang HK,Park KH .2009 .Clinical outcomes after Ahmed valve implantation in refractory paediatric glaucoma. Eye, 23 : 1427-35.
Djodeyre MR,Peralta Calvo J,Abelairas Gomez J. .2001 .Clinical evaluation and risk factors of time to failure of Ahmed Glaucoma Valve implant in pediatric patients. Ophthalmology, 108 : 614-20.
Huang J,Lin J,Wu Z,Xu H,Zuo C,Ge J .2015 .Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure. Clin Ophthalmol, 9 : 977-83.
Papadopoulos M,Cable N,Rahi J,Khaw PT,Willshaw H,Ainsworth J .2007 .The British Infantile and Childhood Glaucoma (BIG) Eye Study. Investig Ophthalmol Vis Sci, 48 : 4100-6.
Shakir M,Bokhari A,Kamil Z,Zafar S. .2013 .Combined trabeculotomy and augmented trabeculectomy in primary congenital glaucoma. J Coll Physicians Surg Pak, 23 : 116-9.
Razeghinejad MR,Kaffashan S,Nowroozzadeh MH .2014 .Results of Ahmed glaucoma valve implantation in primary congenital glaucoma. J AAPOS Off Publ Am Assoc Pediatr Ophthalmol Strabismus, 18 : 590-5.
0

Citations

0

Downloads

48

Views