Diagnostic Utility of Sonography and Magnetic Resonance Imaging in Evaluating Placenta Previa and Its Variants Using Intraoperative Findings as the Gold Standard

Author(s)
Izza Shahid Department of Radiology, Combined Military Hospital,Gujranwala,Pakistan
Nadeem Ibrahim Department of Radiology, Combined Military Hospital,Gujranwala,Pakistan
Sadaf Shafique Department of Obstetrics and Gynaecology, Combined Military Hospital,Gujranwala,Pakistan
Zunaira Zulfiqar Department of Radiology, Combined Military Hospital,Gujranwala,Pakistan
Abstract
Objective: To evaluate the diagnostic utility of ultrasonography and magnetic resonance imaging (MRI) for the diagnosis of placenta previa (PP) with accurate grading, keeping peroperative ndings as the gold standard. Study Design: A cross-sectional study. Place and Duration of the Study: Department of Radiology, Combined Military Hospital, Gujranwala, Pakistan, from March 2023 to April 2024. Methodology: Pregnant women aged 18-45 years in their third trimester with suspected PP were evaluated using transabdominal ultrasound and non-contrast MRI (1.5T). Perioperative ndings during caesarean section served as the gold standard. Diagnostic accuracy was calculated for ultrasonography and MRI in diagnosing the accurate type of PP in terms of sensitivity, speci city, positive predictive value (PPV), negative predictive value (NPV), keeping peroperative ndings as the gold standard. Results: In a total of 110 cases, the mean and gestational ages were 30.56 ± 3.46 years and 33.25 ± 2.95 weeks, respectively. The sensitivity of ultrasound was 83.3%, while MRI demonstrated sensitivity at 95.0%. Ultrasound and MRI showed equally high speci city at 98.0%. The PPV was 98.0% for ultrasound and 98.3% for MRI. The NPV was 83.1% for ultrasound and 94.2% for MRI. The diagnostic accuracy of ultrasound was 90.0%, while MRI achieved a diagnostic accuracy of 96.4%. The diagnostic performance of USG and MRI did not reveal signi cant di erences (p = 0.065). Conclusion: Ultrasonography can be a useful, cost e ective, and safest initial assessment tool for diagnosis and grading of PP in the late pregnancy. It showed overall comparable results of USG and MRI.
Publication Details
Page(s) 698-702
Published Journal: Journal of the College of Physicians and Surgeons Pakistan, Volume: 35, Issue: 06, Year: 2025

Request the full text from PASTIC

Keywords
Ultrasonography, Diagnostic accuracy, Placenta previa, Transabdominal Ultrasound, Gold Standard
References
Jansen CHJR,van Dijk CE,Kleinrouweler CE,Holzscherer JJ,Smits AC,Limpens JCEJM .2022 .Risk of preterm birth for placenta previa or low-lying placenta and possible preventive interventions: A systematic review and meta-analysis. Front Endocrinol (Lausanne), 921220 : 921220.
Jauniaux E,Dimitrova I,Kenyon N,Mhallem M,Kametas NA,Zosmer N .2019 .Impact of placenta previa with placenta accreta spectrum disorder on foetal growth. Ultrasound Obstet Gynecol, 10(5) : 643-9.
Bi S,Zhang L,Wang Z,Chen J,Tang J,Gong J .2021 .E ect of types of placenta previa on maternal and neonatal outcomes: A 10-year retrospective cohort study. Arch Gynecol Obstet, 10(1) : 912-9.
Pegu B,Thiagaraju C,Nayak D,Subbaiah M. .2021 .Placenta accreta spectrum-a catastrophic situation in obstetrics. Obstet Gynecol Sci, 10(3) : 239-47.
Tadayon M,Javadifar N,Dastoorpoor M,Shahbazian N.,Frequency N. .2022 .risk factors, and pregnancy outcomes in cases with placenta accreta spectrum disorder: A case-control study. J Reprod Infertil, 10(4) : 10814-87.
Esako TF,Sparks TN,Kaimal AJ,Kim LH,Feldstein VA,Goldstein RB .2011 .Diagnosis and morbidity of placenta accreta. Ultrasound Obstet Gynecol, 10(3) : 324-7.
Jansen CHJR,Kleinrouweler CE,Kastelein AW,Ruiter L,van Leeuwen E,Mol BW .2020 .Follow-up ultrasound in secondtrimester low-positioned anterior and posterior placentae: Prospective cohort study. Ultrasound Obstet Gynecol, 10(6) : 967-31.
Fratelli N,Prefumo F,Maggi C,Cavalli C,Sciarrone A,Garofalo A .2022 .Third-trimester ultrasound for antenatal diagnosis of placenta accreta spectrum in women with placenta previa: results from the ADoPAD study. Ultrasound Obstet Gynecol, 10(3) : 381-9.
Bourgioti C,Konidari M,Eleftheriades M,Theodora M,Nikolaidou ME,Zafeiropoulou K .2024 .MRI assessed placental location as a diagnostic tool of placental invasiveness and maternal peripartum morbidity. Diagnostics, 10(9) : 925.
Fiocchi F,Monelli F,Besutti G,Casari F,Petrella E,Pecchi A .2020 .MRI of placenta accreta: diagnostic accuracy and impact of interventional radiology on foetal-maternal delivery outcomes in high-risk women. Br J Radiol, 10(1114) : 20200267.
Rosenberg T,Pariente G,Sergienko R,Wiznitzer A,Sheiner E .2011 .Critical analysis of risk factors and outcome of placenta previa. Arch Gynecol Obstet, 10(1) : 47-51.
Marshall NE,Fu R,Guise JM .2011 .Impact of multiple cesarean deliveries on maternal morbidity: A systematic review. Am J Obstet Gynecol, 06(3) : 262-8.
Im DH,Kim YN,Cho EH,Kim DH,Byun JM,Jeong DH JM .2023 .Risk factors and pregnancy outcomes of antepartum hemorrhage in women with placenta previa. Reprod Sci, 10(9) : 2728-35.
Ding J,Wang G,Ling Y. .2023 .The value of MRI in the diagnosis of placenta previa. Int J Computat Intellig Sys, 10(1) : 64.
Othman AIA,Ibrahim MEA,Mansour DY .2018 .Diagnostic accuracy of MRI criteria in predilection of morbidly adherent placenta. Egypt J Radiol Nuclear Med, 49(3) : 53-005141.
Jain V,Bos H,Bujold E .2019 .Diagnosis and management of placenta previa. J Obstet Gynaecol Can, 07(7) : 906-17.
D'Antonio F,Iacovella C,Palacios-Jaraquemada J,Bruno CH,Manzoli L,Bhide A .2014 .Prenatal identi cation of invasive placentation using magnetic resonance imaging: ySstematic review and meta-analysis. Ultrasound Obstet Gynecol, 10(1) : 8-16.
Leerentveld RA,Gilberts EC,Arnold MJ,Wladimiro JW .1990 .Accuracy and safety of transvaginal sonographic placental localization. Obstet Gynecol, 10(5 Pt 1) : 00006250-62.
Hong S,Le Y,Lio KU,Zhang T,Zhang Y .2022 .Performance comparison of ultrasonography and magnetic resonance imaging in their diagnostic accuracy of placenta accreta spectrum disorders: A systematic review and metaanalysis. Insights Imaging, 10(1) : 50.
Nawab K,Naveed S,Khan M. .2017 .Diagnostic accuracy of ultrasound (U/S) and magnetic resonance imaging (MRI) in prenatal diagnosis of placenta accreta taking operative ndings as gold standard. Pak J Radiol, 27(4) : 317-22.
0

Citations

0

Downloads

58

Views