No Detail Found!

MALDI-TOF-MS Application in M-Protein Detection and Its Associations with Clinical Laboratory Findings in Geriatrics

Author(s)
Jing Cheng Department of Geriatrics, Affiliated Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
Yuying Zhang Department of Human Biology Programme, University of Toronto, Toronto, Canada
Mingjie Cao Department of Geriatrics, Affiliated Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
Yun Sun Department of Geriatrics, Affiliated Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
Xiaomin Lv Department of Geriatrics, Affiliated Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
Haiya Wang Department of Geriatrics, Affiliated Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
Abstract
Currently, the methods used to detect M-protein such as SPEP (serum M-protein electrophoresis), IFE (immuno xation electrophoresis), and sFLC (serum free light chain) assay are hyposensitive, laborious, time-consuming, and expensive. In this study, the authors assessed the performance of MALDI-TOF-MS in the detection of M-protein in geriatrics. With IFE as the gold standard, the speci city, sensitivity, and consistency of MALDI-TOF-MS were 92.30, 89.68, and 90.06%, respectively. MALDI-TOF-MS achieved an agreement of 100.00, 100.00, 89.68, 88.89, and 87.50% in the detection of IgA, biclonal, negative, IgM, and IgG isotypes of M-protein, respectively. In addition, the results showed that the glycosylated haemoglobin level was increased in the MS-IFE+ group as compared to the MS+IFE- group. This study supports that the MALDI-TOF-MS is an alternative method for M-protein detection in aged subjects. The di erence in glycosylated haemoglobin level may provide an explanation for the di erent detection results for M-protein between IFE and MALDI-TOF-MS.
Publication Details
Page(s) 528-530
Published Journal: Journal of the College of Physicians and Surgeons Pakistan, Volume: 35, Issue: 04, Year: 2025

Request the full text from PASTIC

Keywords
Immuno xation electrophoresis, M-protein, MALDI-TOF-MS, Clinical laboratory ndings, The aged
References
Katzmann JA,Clark RJ,Abraham RS,Bryant S,Lymp JF,Bradwell AR .2002 .Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: Relative sensitivity for detection of monoclonal light chains. Clin Chem, 48(9) : 1437-44.
Moore AR,Brown K,Chapman C .2023 .Mass spectrometric-based assessment of the serum kappa to lambda immunoglobulin light chain ratio (kappa: Lambda) in dogs with immunoglobulin secretory diseases. Vet Comp Oncol, 10(3) : 460-8.
Mehra N,Gopisetty G,Subramani J,Dhanasekar S,Rajamanickam A,Kalaiyarasi JP .2023 .Detection of serum Mprotein in acetonitrile precipitates by MALDI-TOF mass spectrometry: A novel, low-cost methodology. Ann Clin Biochem, 10(5) : 339-48.
Cohen HJ .2006 .Prevalence of monoclonal gammopathy of undetermined signi cance. N Engl J Med, 10(26) : 2832.
Turner KA,Frinack JL,Ettore MW,Tate JR,Graziani MS,Jacobs JFM .2020 .An international multi-center serum protein electrophoresis accuracy and M-protein isotyping study. Part I: Factors impacting limit of quantitation of serum protein electrophoresis. Clin Chem Lab Med, 10(4) : 533-46.
Mills JR,Kohlhagen MC,Dasari S,Vanderboom PM,Kyle RA,Katzmann JA .2015 .Comprehensive assessment of Mproteins using nanobody enrichment coupled to MALDITOF mass spectrometry. Clin Chem, 253740(10) : 1334-44.
Patil S,Biradar SM,Holyachi R,Devarmani S,Reddy S. .2023 .Assessment of serum electrolytes and glycated hemoglobin level in non-diabetic iron-de cient anaemic patients. Cureus, 10(5) : .
0

Citations

0

Downloads

86

Views