No Detail Found!

Comparison of thermal performances predicted and experimental of solar air collector.

Author(s)
Aarzu Sencan Department of Mechanical Education, Faculty of Technical Education, Suleyman Demirel University, Usoarta, Turkey
Gokhan Ozdemir Department of Training, ISDEMIR Iskenderun Iron and Steel Works Co, Iskenderun, Turkey
Abstract
In this study, thermal performance of solar air collector system which was experimentally constructed was obtained for different operating conditions. Experiments were conducted under turkey/Mersin climatic conditions. Then, Neural Network (NN) models have been developed for the prediction the thermal performance of solar air collectors. Experimental data were used for training and testing of the networks. The inputs of the network are inlet and outlet air temperature to collector, solar radiation and air mass flow rate and the output is thermal performance of solar air collector. Using the weights obtained from the trained network a new formulation is presented for the calculation of the performance; the use of NN is proliferating with high speed in simulation. The R2-values obtained when unknown data were used to the networks was 0.9985 which is very satisfactory. The use of this new formulation, which can be employed with any programming language or spreadsheet program for the estimation of the thermal performance of solar air collectors, as described in this paper, may make the use of dedicated NN software unnecessary.
Publication Details
Page(s) 3721-3728
DOI DOI not available
Published Journal: Journal of Applied Sciences, Volume: 7, Issue: 23, Year: 2007

Request the full text from PASTIC

0

Citations

0

Downloads

38

Views