Comparison of bubble CPAP versus head box oxygen in preterm neonates with respiratory distress syndrome

Author(s)
Annam Asif Department of Pediatrics, National University of Medical Sciences NUMS, 4Kahuta Research Laboratory, Rawalpindi, Pakistan
Ammara Ayub Islamic International Medical College Trust IIMCT, Rawalpindi, Pakistan
Sajid Ali Shah National University of Medical Sciences NUMS,, Rawalpindi, Pakistan
Sugra Wahid Kahuta Research Laboratory, Rawalpindi, Pakistan
Saeed Zaman National University of Medical Sciences NUMS,, Rawalpindi, Pakistan
Lutfullah Goheer National University of Medical Sciences NUMS,, Rawalpindi, Pakistan
Abstract
Objective: To compare bubble continuous positive airway pressure (CPAP) and head box oxygen in preterm neonates with respiratory distress syndrome (RDS) in terms of frequency of successful weaning. Methodology: A quasi experimental study conducted at The Neonatal Intensive Care Unit (NICU) of Kahuta Research Laboratory Hospital, Islamabad from January 2019 to January 2020. A total of 100 (50 in each group) preterm neonates having RDS were randomly distributed in two groups. Group-A neonates received respiratory support via head box and Group-B received support via bubble CPAP. Clinical course was assessed as shifting of baby from bubble CPAP to mechanical ventilation or successful weaning. Results:  In a total of 100 neonates (50 in each group),  46 (46.0%) were male and 52 (52.0%) females. Mean  age in Group-A and Group-B was 32 ± 2.8 weeks and  33 ± 3.12 weeks, respectively. In Group-A (head box),  21 (42.0%) neonates had successful weaning while in  Group-B (bubble CPAP) 39 (78.0%) had successful  weaning (p = 0.0002).  Conclusion:  Preterm neonates with RDS on bubble  CPAP wean off earlier than those preterm neonates  with RDS on head box oxygen. 
Publication Details
Page(s) 50-53
DOI DOI not available
Published Journal: Rawal Medical Journal, Volume: 48, Issue: 1, Year: 2023

Request the full text from PASTIC

Keywords
Neonate, preterm, Continuous positive airway pressure, Respiratory distress syndrome., head box oxygen
References
Qari SA,Alsufyani AA,Muathin SH,El Margoushy NM .2018 .Prevalence of respiratory distress syndrome in neonates. Egypt J Hosp Med, 70 : 257-64.
Sardesai S,Biniwale M,Wertheimer F,Garingo A,Ramanathan R .2017 .Evolution of surfactant therapy for respiratory distress syndrome: past, present, and future. Pediatr Res, 81 : 240-8.
Razak A,Faden M. .2020 .Neonatal lung ultrasonography to evaluate need for surfactant or mechanical ventilation: a systematic review and meta-analysis. Arch Dis Child Fetal Neonatal Ed, 105 : 164-71.
Condò V,Cipriani S,Colnaghi M,Bellù R,Zanini R,Bulfoni C .2017 .Neonatal respiratory distress syndrome: are risk factors the same in preterm and term infants. J Matern Fetal Neonatal Med, 30 : 1267-72.
Ferguson KN,Roberts CT,Manley BJ,Davis PG .2017 .Interventions to improve rates of successful extubation in preterm infants: a systematic review and meta-analysis. JAMA Pediatr, 171 : 165-74.
Abbas SK,Maqsood M,Shamim S .2015 .Success of Locally Devised Continuous Positive Pressure Ventilation (CPAP) alone or in combination with Surfactant Therapy in the Management of Respiratory Distress Syndrome in Preterm Neonates. Ann Abbasi Shaheed Hosp Karachi Med Dent Coll, 20 : 103-8.
Kumar RM,Kabra SK,Singh M. Efficacy .1997 .and acceptability of different modes of oxygen administration in children: Implications for a community hospital. J Trop Pediatr, : 47-49.
Bernard GR,Artigas A,Brigham KL,Carlet J,Falke K,Hudson L .1994 .The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination. Am J Respir Crit Care Med, 149 : 818-24.
Özkan H,Erdeve Ö,Kutman HG .2018 .Turkish Neonatal Society guideline on the management of respiratory distress syndrome and surfactant treatment. Turk Arch Pediatr, 53 : S45.
Al Riyami N,Al Hadhrami A,Al Lawati T,Pillai S,Abdellatif M,Jaju S M .2020 .Respiratory Distress Syndrome in Neonates Delivered at Term-gestation by Elective Cesarean Section at Tertiary Care Hospital in Oman. Oman Med J, : e133.
Lee M,Wu K,Yu A,Roumiantsev S,Shailam R,Nimkin K .2019 .Pulmonary hemorrhage in neonatal respiratory distress syndrome: radiographic evolution, course, complications and long-term clinical outcomes. J Neonatal-perinatal Med, 12 : 161-71.
Sullivan CE,Issa FG,Berthon-Jones M,Eves L M .1981 .Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares. Lancet, 1 : 862-5.
Drevhammar T,Berg N,Nilsson K,Jonsson B,Prahl B .2021 .Flows and function of the Infant Flow neonatal continuous positive airway pressure device investigated with computational fluid dynamics. Acta Paediatr, 110 : 811-7.
Derdak S,Mehta S,Stewart TE .2002 .High-frequency oscillatory ventilation for acute respiratory distress syndrome in adults: a randomized, controlled trial. Am J Respir Crit Care Med, 166 : 801-8.
McPherson C .2018 .Prevention and treatment of respiratory distress syndrome in preterm neonates. Neonatal Network, 37 : 169-77.
Read B,Lee DS,Fraser D .2016 .Evaluation of a practice guideline for the management of respiratory distress syndrome in preterm infants: A quality improvement initiative. Paediatr Child Health, 21 : e4-9.
Soomro T,Tikmani SS .2016 .Success of Bubble CPAP in Treatment of Respiratory Distress Syndrome in Preterm Infants. J Gen Pract, 4 : 1000264.
Gupta N,Saini SS,Murki S,Kumar P,Deorari A .2015 .Continuous positive airway pressure in preterm neonates: an update of current evidence and implications for developing countries. Indian Pediatr, 52 : 319-28.
0