An automatic land leveling control system (ALLCS) consists of different sections such as electronic circuitry, laser and hydraulic devices in order to adjust the height of scraper. A laser beam strikes a photocell array and then the electronic circuit detects the level of the laser beam. If the level of laser beam is not the same as set point, a control signal is transmitted in order to adjust the height of the scraper. In this paper, investigation on design and operation of different parts of the ALLCS are presented. The steady state and transient responses of the system are also discussed. First, the whole system and also the design of its components are described. The block diagram of control system and the mathematical model of its various sections are presented next. Then, based on these equations, the mathematical model of whole system is derived. This model is solved and analyzed by MATLAB`s Simulink and the responses of system to different inputs are obtained. The transient response of system to inputs of 10 and -8.5 cm amplitude step functions for embankment and landscape, respectively were investigated. For the embankment, the response was over damped and the time to reach the steady state was 1.15 second. The difference between steady state error simulation and experiment was about 0.04 mm. For the landscape case, the response was over-damped too. However, the steady state response time was faster. This is due to the fact that the height for landscape case was smaller. Based on the experimental and simulation results, the validity of the model is confirmed. The model may be used as a reference to evaluate the functionality of the control system at different operating conditions.