No Detail Found!

How NIRS can predict the outcome of patient in low systemic pressure: a case series

Author(s)
Purwoko Department of Anesthesiology & Intensive Therapy, Faculty of Medicine, Universitas Sebelas Maret / Moewardi General Hospital,Surakarta,Indonesia
Septian Adi Permana Department of Anesthesiology & Intensive Therapy, Faculty of Medicine, Universitas Sebelas Maret / Moewardi General Hospital,Surakarta,Indonesia
Fitri Hapsari Dewi Department of Anesthesiology & Intensive Therapy, Faculty of Medicine, Universitas Sebelas Maret / Moewardi General Hospital,Surakarta,Indonesia
Prasdhika Arie Prihandana Department of Anesthesiology & Intensive Therapy, Faculty of Medicine, Universitas Sebelas Maret / Moewardi General Hospital,Surakarta,Indonesia
Abstract
Mitral valve replacement (MVR) is a surgical procedure to treat mitral regurgitation (MR). As there is an increase in the afterload in the postoperative period, patients tend to have low cardiac output syndrome. This condition may limit oxygen delivery to body tissues. Improved venous saturation has been linked to positive neurological outcomes. Near-infrared spectroscopy (NIRS) is the new technique to monitor regional oxygenation in real time. This study reports on four patients who underwent MVR due to a combination of severe mitral stenosis (MS) and mild MR. All patients had complaints of dyspnea on exertion to unbearable chest pain. Physical and work-up examination led to a diagnosis of decompensated heart failure, concomitant valve disorder, fluid overload, and cardiomegaly. Preoperative catheterization to stratify the risks of the procedure was done on all four patients. The surgery planned was cardiopulmonary bypass (CPB) with standard monitoring and additional NIRS measurement. The measurement of mean arterial pressure (MAP) and NIRS were tightly monitored and maintained in each patient, with the use of vasoactive agents. All four patients suffered unstable hemodynamics and were admitted to intensive care unit with the support of mechanical ventilation and other supportive therapies. Cerebral perfusion can reach the baseline normal value even though in low cardiac output syndrome, and NIRS can predict the outcome of the patients better than the conservative monitoring.
Publication Details
Page(s) 757-762
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 27, Issue: 6, Year: 2023

Request the full text from PASTIC

Keywords
Mitral Valve Replacement, NIRS, Cerebral perfusion, Low Systemic Pressure, CPB
References
Island (FL): StatPearls Publishing Treasure,Sazzad F,Wadud MA,Uddin MA,Roy SP,Sarkar PK .2021 .Low Cardiac Output Syndrome: Incidence after Mitral Valve Replacement with or without Preservation of Mitral Valve Apparatus. Mymensingh Med, 30(1) : 164-170.
. .. , 36(6) : 1173-8.
Green MS,Sehgal S,Tariq R.,Near-Infrared Spectroscopy .2016 .The New Must Have Tool in the Intensive Care Unit? Semin Cardiothorac Vasc Anesth. , 20(3) : 213-24.
DeMers D,Wachs D.,Physiology D.,Island (FL): StatPearls Publishing D. .2023 .Mean Arterial Pressure. , : .
Lie SL,Hisdal J,Høiseth LØ .2021 .Cerebral blood flow velocity during simultaneous changes in mean arterial pressure and cardiac output in healthy volunteers. Eur J Appl Physiol, 121(8) : 2207-2217.
Sørensen H. .2016 .Near infrared spectroscopy evaluated cerebral oxygenation during anesthesia. Dan Med, 63(12) : B5318.
. .Regulation of cerebral blood flow in humans: physiology and clinical implications of autoregulation. Physiol Rev. 2021 Oct, 1(4) : 1487-1559.
Hawryluk G,Whetstone W,Saigal R,Ferguson A,Talbott J,Bresnahan J .2014 .Mean Arterial Blood Pressure Correlates with Neurological Recovery after Human Spinal Cord Injury: Analysis of High Frequency Physiologic Data. 2015 Dec, 32(24) : 1958-67.
Brown CH,Neufeld KJ,Tian J,Probert J,Laflam A,Max L .2019 .Effect of Targeting Mean Arterial Pressure During Cardiopulmonary Bypass by Monitoring Cerebral Autoregulation on Postsurgical Delirium Among Older Patients: A Nested Randomized Clinical Trial. 2019 Sep, 1(9) : 819-826.
Tosh W,Patteril M. .2016 .Cerebral oximetry. BJA Educ, 10(12) : 417-21.
0

Citations

0

Downloads

33

Views