No Detail Found!

Ultrasound-guided inferior vena cava collapsibility index as a predictor of fluid responsiveness in septic cancer patients

Author(s)
Mohamed Ahmed Gaafar National Cancer Institute, Cairo University, Cairo, Egypt
Ahmed M Soliman National Cancer Institute, Cairo University, Cairo, Egypt
Naglaa Abdallah Ahmed National Cancer Institute, Cairo University, Cairo, Egypt
Tamer Ahmed Kotb National Cancer Institute, Cairo University, Cairo, Egypt
Ehab Hanafy Shaker National Cancer Institute, Cairo University, Cairo, Egypt
Abstract
Background & objective : Intravenous fluid therapy is a crictial step in the resuscitation of patients suefring fr om sepsis and septic shock. Meticulous h emodynamic monitoring is necessary before as well as during the fluid therapy to avoid under- as well as over-loading the patient. An evaluation of fluid status has been suggested to be done noninvasively using the inferior vena cava collapsibility index (IVC-CI). We assessed the eefcvtieness of IVC -CI in evaluating septic patients' responses to fluid t herapy at our institution . Methodology: Forty cancer patients with spontaneous breat hing, who met sepsis criteria and were admietd to the intensive care unit, were included in this cross-secotinal study. Over the course of three hours, the patients received crystalloids intravenously at a rate of 30 ml/kg, while CVP, ultrasonography guided IVC-CI measurement, and the vital sign monitoring was done every 30 min. Patients were divided into a responder group and a non-responder group based on a 10% change in cardiac output (CO) one hour later. IVC-CI variations in the volume responsiveness predicotin served as the main outcome measure. Results: According to the change in CO one hour aeftr starting fluid treatment, 29 patients (72.5%) were classified as lfuid responsive and the remaining 11 (27.5%) as fluid non -responsive. In the two groups, HR and IVC-CI decreased significantly ; whereas MAP, CVP, and CO increased significantly. ROC -curve analysis showed a percent change = 3.4% of IVC-CI predicted posivtie responsiveness with a sensivtiity of 72.4% and a specificity of 63.6%. These values were 79.3% and 72.7%, respecvtiely, for a change = 6.3% aeftr one hour. The baseline value of IVC-CI was not predicvtie of responsiveness. Conclusion: In cancer patients with sepsis or septic shock, the change in inferior vena cava collapsibility index during the first hour of fluid therapy can predict fluid responsiveness with a moderate degree of accuracy. 
Publication Details
Page(s) 547-552
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 28, Issue: 3, Year: 2024

Request the full text from PASTIC

Keywords
Sepsis, Cancer, ICU, Inferior vena cava, IVC collapsibility index, Non-invasive cardiometry, Critically sick
References
Rhodes A,Evans LE,Alhazzani W,Levy MM,Antonelli M,Ferrer R .2017 .Surviving Sepsis Campaign: International Guidelines for Management of Sepsis. Intensive Care Med, 43 : 304-77.
.2016 .. , : G1-12.
.2007 .. , 116 : 793-802.
Hippensteel JA,Uchimido R,Tyler PD,Burke RC,Han X,Zhang F .2019 .Intravenous fluid resuscitation is associated with septic endothelial glycocalyx degradation. Crit Care, 23 : 259.
. .. [PubMed] DOI: 10.1186/s13054-019-2534-2, : .
Res Cardiovasc .2021 .. , 117 : 60.
Kelm DJ,Perrin JT,Cartin-Ceba R,Gajic O,Schenck L,Kennedy CC .2015 .Fluid overload in patients with severe sepsis and septic shock treated with early goal-directed therapy is associated with increased acute need for fluid-related medical interventions and hospital death. Shock, 43 : 68-73.
. .. , : .
Brotfain E,Koyfman L,Toledano R,Borer A,Fucs L,Galante O .2016 .Positive fluid balance as a major predictor of clinical outcome of patients with sepsis/septic shock after ICU discharge. Am J Emerg Med, 07 : 2122-6.
Indian J Crit Care Med .2015 .. , 19 : 171356-5229.
Marik PE,Linde-Zwirble WT,Bittner EA,Sahatjian J,Hansell D. .2017 .Fluid administration in severe sepsis and septic shock, patterns and outcomes: an analysis of a large national database. Intensive Care Med, 43 : 625-32.
Bentzer P,Griesdale DE,Boyd J,MacLean K,Sirounis D,Ayas NT .2016 .Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids? JAMA.. , 316 : 1298-309.
Douglas IS,Alapat PM,Corl KA,Exline MC,Forni LG,Holder AL .2020 .Fluid Response Evaluation in Sepsis Hypotension and Shock: A Randomized Clinical Trial. Chest, 04 : 1431-45.
Garg M,Sen J,Goyal S,Chaudhry D .2016 .Comparative evaluation of central venous pressure and sonographic inferior vena cava variability in assessing fluid responsiveness in septic shock. Indian J Crit Care Med, 20 : 195706-5229.
Vaish H,Kumar V,Anand R,Chhapola V,Kanwal SK .2017 .The Correlation Between Inferior Vena Cava Diameter Measured by Ultrasonography and Central Venous Pressure. Indian J Pediatr, 84 : 757-62.
Zhu CL,Yao RQ,Li LX,Li P,Xie J,Wang JF .2021 .Mechanism of Mitophagy and Its Role in Sepsis Induced Organ Dysfunction: A Review. Front Cell Dev Biol, 9 : 664896.
Broyles MG,Subramanyam S,Barker AB,Tolwani AJ .2021 .Fluid Responsiveness in the Critically Ill Patient. Adv Chronic Kidney Dis, 06 : 20-8.
Zamboni P,Malagoni AM,Menegatti E,Ragazzi R,Tavoni V,Tessari M .2020 .Central venous pressure estimation from ultrasound assessment of the jugular venous pulse. PLoS One, 15 : e0240057.
Baumann UA,Marquis C,Stoupis C,Willenberg TA,Takala J,Jakob SM .2004 .Estimation of central venous pressure by ultrasound. Resuscitation, 08 : 193-9.
Brennan JM,Ronan A,Goonewardena S,Blair JEA,Hammes M,Shah D .2006 .Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic. Clin J Am Soc Nephrol, 1 : 749-53.
Marcelli E,Cercenelli L,Bortolani B,Marini S,Arfilli L,Capucci A .2021 .A Novel Non-Invasive Device for the Assessment of Central Venous Pressure in Hospital, Office and Home. Med Devices (Auckl), 14 : 141-54.
2Blehar DJ,Resop D,Chin B,Dayno M,Gaspari R .2012 .Inferior vena cava displacement during respirophasic ultrasound imaging. Crit Ultrasound J, 4 : 18.
Baker EC,Pott J,Khan F,Freund Y,Harris T. .2015 .Best approach to measuring the inferior vena cava in spontaneously ventilating patients: a pilot study. Eur J Emerg Med, 22 : 58-61.
Di Nicolò P,Tavazzi G,Nannoni L,Corradi F.,Inferior F. .2023 .Vena Cava Ultrasonography for Volume Status Evaluation: An Intriguing Promise Never Fulfilled. J Clin Med, 12 : 2217v.
Lanspa MJ,Grissom CK,Hirshberg EL,Jones JP,Brown SM .2013 .Applying dynamic parameters to predict hemodynamic response to volume expansion in spontaneously breathing patients with septic shock. Shock, 39 : 155-60.
Preau S,Bortolotti P,Colling D,Dewavrin F,Colas V,Voisin B .2017 .Diagnostic Accuracy of the Inferior Vena Cava Collapsibility to Predict Fluid Responsiveness in Spontaneously Breathing Patients With Sepsis and Acute Circulatory Failure. Crit Care Med, 45 : e290-7.
Lu N,Xi X,Jiang L,Yang D,Yin K. Exploring .2017 .the best predictors of fluid responsiveness in patients with septic shock. Am J Emerg Med, 03 : 1258-61.
Orso D,Paoli I,Piani T,Cilenti FL,Cristiani L,Guglielmo N.,Meta-Analysis N. .2020 .Accuracy of Ultrasonographic Measurements of Inferior Vena Cava to Determine Fluid Responsiveness: A Systematic Review. J Intensive Care Med, 35 : 354-63.
Brennan JM,Blair JE,Goonewardena S,Ronan A,Shah D,Vasaiwala S .2007 .A comparison by medicine residents of physical examination versus hand-carried ultrasound for estimation of right atrial pressure. Am J Cardiol, 01 : 1614-6.
Zhao J,Wang G .2016 .Inferior Vena Cava Collapsibility Index is a Valuable and Non-Invasive Index for Elevated General Heart End-Diastolic Volume Index Estimation in Septic Shock Patients. Med Sci Monit, 22 : 3843-8.
0

Citations

0

Downloads

39

Views