No Detail Found!

Investigation of daylight availability in university dining halls: A case study at the University of Jordan

Author(s)
Eman Mayah Department of Design and Visual Communication, College of Art and Design, University of Jordan, Amman, Jordan
Abstract
This study evaluates the availability of daylight inside a university's dining halls over two days (one sunny and one cloudy) using light meters in real-life sittings. Quantitative monitoring was conducted for horizontal and vertical illuminance levels (HILs and VILs) derived from daylight inside of the dining halls and outside under an unobstructed sky, along with monitoring of the illuminance levels of the artificial light inside. The results are discussed in relation to the minimum recommended HIL value in dining halls of educational buildings (150 lux) set by the Jordanian National Construction Constitution's lighting code. Further, a questionnaire was conducted with 239 students and employees to evaluate daylight and artificial light from the user's perspective of the dining halls. HIL, as a dependent variable, was found to vary between the two examined halls, which had different façade fenestrations and hall characteristics. The analysis found that, within the halls, only the area within a 2-metre distance from the north- and west-oriented windows complied with the recommended value, except at breakfast time on a cloudy day. The middle and deepest areas of both halls were significantly lacking in daylight on both cloudy and sunny days. The subjective mean evaluation corresponds with the daylight VILs but contradicts the artificial illuminance levels. As such, subjective needs and preferences may not correspond with objective measurements. This study opens a new path of daylighting research for a largely neglected space: foodservice halls in educational buildings.
Publication Details
Page(s) 216-233
Published Journal: Journal of Daylighting, Volume: 11, Issue: 2, Year: 2024

Request the full text from PASTIC

Keywords
Daylighting, Illuminance levels, Foodservice halls, University dining hall
References
Horng J. S.,Chou S. F.,Liu C. H.,Tsai C. Y. .2013 .Creativity, aesthetics and eco-friendliness: A physical dining environment design synthetic assessment model of innovative restaurants. Tour. Manag, 36 : 15-25.
Birchfield J. C.,Sparrowe R. T. .2003 .Design and Layout of Foodservice Facilities, 2nd editio. , : .
Mannapova R.,N R. .2020 .ORGANIZATION AND BASIC REQUIREMENTS FOR RESTAURANT DESIGN INTERIOR, Novat. Publ. Int. J. Innov. Eng. Res. Technol, 7 : 2394-3696.
Han H.,Ryu K. .2009 .The roles of the physical environment, price perception, and customer satisfaction in determining customer loyalty in the restaurant industry. J. Hosp. Tour. Res, 33 : 487-510.
Robson S. K. A.,Kimes S. E. .2007 .. Examining the Effects of Full-Spectrum Lighting in a Restaurant, : .
. S Y Y Alsharhan, D .2017 .DineLight: Lighting and The Dining Experience. , : .
Ariffin H. F.,Bibon M. F.,Abdullah R. P. S. R. .2012 .Restaurant's Atmospheric Elements: What the Customer Wants. Procedia - Soc. Behav. Sci, 38 : 380-387.
Hassanain M. A.,Mathar H.,Aker A. .2016 .Post-occupancy evaluation of a university student cafeteria. Archit. Eng. Des. Manag, 12 : 67-77.
Liang X.,S. Zhang, X. .2009 .Investigation of customer satisfaction in student food service: An example of student cafeteria in NHH, Int. J. Qual. Serv. Sci, 1 : 113-124.
Andaleeb S. S.,Caskey A. .2007 .Satisfaction with food services: Insights from a college cafeteria. J. Foodserv. Bus. Res, 10 : 51-65.
Bellia L.,Pedace A.,G. Barbato, A. .2013 .Lighting in educational environments: An example of a complete analysis of the effects of daylight and electric light on occupants, Build. , : .
Zazarin S. M.,Aziz Z. Abdul,Heng Yii Sern C. .2023 .A Study on Daylight Conditions of Dementia Care Facilities in Malaysia. J. Kejuruter, 6 : 89-102.
Acosta I.,Munoz C.,Campano M. A.,Navarro J. .2015 .Analysis of daylight factors and energy saving allowed by windows under overcast sky conditions. Renew. Energy, 77 : 194-207.
M. G. M. Stokkermans Y.,Chen M. J.,Murdoch and I. M. C. L.,Vogels and I. M. C. L. .2015 .Effect of daylight on atmosphere perception: comparison of a real space and visualizations. , : .
Drosou N.,Brembilla E.,Mardaljevic J.,Haines V. .2016 .Measuring Actual Daylighting Performance in Classrooms. in 36th International Conference on Passive and Low Energy Architecture, : 953-959.
Brembilla E.,Drosou N. C.,Mardaljevic J. .2022 .Assessing daylight performance in use: A comparison between long-term daylight measurements and simulations. Energy Build 262, : .
Viula R.,Bokel R.,Tenpierik M. .2023 .Prediction of discomfort from glare from daylight in classrooms. Light. Res. Technol, 55 : 712-729.
Mayah E.,Theses Global - ProQuest E. .2021 .The Investigation of façade Fenestration for Daylighting Levels and Experienced Atmosphere in Design Studios Under Overcast Sky - ProQuest Dissertations. , : .
Mayah E.,Hanna R.,Levels Daylight .2019 .. Int. J. Archit. Environ. Eng, 13 : 313-324.
Raja Mohd Yazit R. N. S.,Husini E. Mohd,Khamis M. K.,Zolkefli M. F.,Dodo Y. A. .2020 .. Univ. Educ, 16 : 125.
Singh P.,Singh M. P.,Arora R.,Performance R. .2014 .Its impact on Students' Health Exposure. , : .
Alah A.,Khanmohammadi M.,Masoudinejad M.,Alirezaie B. .2016 .Improving student performance by proper utilization of daylight in educational environments (Case study: IUST 1 School of Architecture). Acta Tech. Napocensis Civ. Eng. Archit, 59 : .
Zomorodian Z. S.,Korsavi S. S.,Tahsildoost M. .2016 .The effect of window configuration on daylight performance in classrooms: A field and simulation study. Int. J. Archit. Eng. Urban Plan, 26 : 15-24.
Korsavi S. S.,Zomorodian Z. S.,Tahsildoost M. .2016 .Visual comfort assessment of daylit and sunlit areas: A longitudinal field survey in classrooms in Kashan. Energy Build 128, : 305-318.
Kim .2014 .Daylight evaluation for educational facilities established in high-rise housing complexes in Daegu, South Korea, Build. , : .
Bakmohammadi P.,Noorzai E. .2020 .Optimization of the design of the primary school classrooms in terms of energy and daylight performance considering occupants' thermal and visual comfort. Energy Reports 6, : 1590-1607.
Freewan A. A. Y.,Al J. A.,Dalala J. A. .2020 .Assessment of daylight performance of Advanced Daylighting Strategies in Large University Classrooms; Case Study Classrooms at JUST, Alexandria Eng. J 59, : 791-802.
Zomorodian Z. S.,Tahsildoost M. .2019 .Assessing the effectiveness of dynamic metrics in predicting daylight availability and visual comfort in classrooms, Renew. , : 669-680.
Barzanooni N.,Haghgou H. R.,Renew J. .2019 .Designing and Application of Solar Active Systems for Hakim Sabzevari University: A Case Study of the Dining Hall. Energy Environ. JJREE 6, : 1-7.
Barmore-Mccollum K.,Post-Holmberg S.,Griffin C. T. .2014 .. , : .
Raynham P.,Boyce P. R.,Fitzpatrick J. .2012 .. The SLL code for lighting. London: CIBSE, : .
Secker S. M.,Ma P. J. L. .1987 .Daylight availability and lighting use : Geographical, Light. Res. Technol, 19 : 25-34.
Hopkinson and J. D. Kay R. G. .1969 .. , : .
Tregenza P.,Wilson M. .2011 .Daylighting: architecture and lighting design. London: Routledge, : .
Society R. S.,Aldawood F. .1988 .. Jordanian National Construction Constitution: Interior Lighting Code. Amman: Ministry of Public Works & Housing, : .
Xue P.,Mak C. M.,Cheung H. D. .2014 .The effects of daylighting and human behavior on luminous comfort in residential buildings: A questionnaire survey. Build. Environ, 81 : 51-59.
Hanna R. .2002 .Environmental appraisal of historic buildings in Scotland: The case study of the Glasgow School of Art, Build. Environ, 37 : 1-10.
Brembilla E.,Mardaljevic J. .2019 .Climate-Based Daylight Modelling for compliance verification: Benchmarking multiple state-of-the-art methods. Build. Environ, 158 : 151-164.
Brembilla E.,Chi D. A.,Hopfe C. J.,Mardaljevic J. .2019 .Evaluation of climate-based daylighting techniques for complex fenestration and shading systems. Energy Build 203, : .
Chi D. A.,Moreno D.,Navarro J. .2018 .Correlating daylight availability metric with lighting, heating and cooling energy consumptions. Build. Environ, 132 : 170-180.
Bellia L.,Fragliasso F.,Stefanizzi E. .2017 .Daylit offices: A comparison between measured parameters assessing light quality and users' opinions, Build. Environ, 113 : 92-106.
Chamilothori K.,Rodrigues J.,Dan-Glauser E. S.,Wienold J.,Andersen M. .2019 .Subjective and physiological responses to façade and sunlight pattern geometry in virtual reality. Build. Environ, 150 : 144-155.
Mardaljevic J.,Cannon-Brookes S.,Blades N.,Lithgow K. .2021 .Reconstruction of cumulative daylight illumination fields from high dynamic range imaging: Theory, deployment and in-situ validation. Light. Res. Technol, 53 : 311-331.
Wong I. L. .2017 .A review of daylighting design and implementation in buildings. Renewable and Sustainable Energy Reviews, 74 : 959-968.
Mardaljevic J. .2013 .Rethinking daylighting and compliance. SDAR* J. Sustain. Des. Appl. Res. Res 1, : .
Tregenza P.,Mardaljevic J. .2018 .Daylighting buildings: Standards and the needs of the designer. Light. Res. Technol, 50 : 63-79.
Timeanddate ,Date AS .2024 .. , : .
.2024 .7&year=2023 (accessed Feb. , 20 : .
Meteoblue .2024 .. , 20 : .
Flynn J. E.,Spencer T. J.,Martyniuk O.,Hendrick C. .1973 .interim study of procedures for investigating the effect of light on impression and behavior. J. Illum. Eng. Soc 3, : 87-94.
L. J. Cronbach .1951 .COEFFICIENT ALPHA AND THE INTERNAL STRUCTURE OF TESTS*. Psychometrika, 16 : 297-334.
J. M. Cortina .1993 .An Examination of Theory and Applications. J. Appl. Psychol, 78 : 98-104.
VELUX ,Daylight calculator .2024 .. , : .
.2024 .. , 20 : .
VELUX .2020 .. , : .
.2024 .. (accessed Feb, 20 : .
Hopkinson R. G.,Petherbridge P.,Longmore J. .1966 .. , : .
Robinson A.,Selkowitz S. .2013 .Tips for Daylighting with Windows. United States, : .
0

Citations

0

Downloads

63

Views