No Detail Found!

Evaluation of fasting and random plasma glucose for diagnosis of gestational diabetes

Author(s)
Sikandar Hayat Khan Department of Pathology, PNS Rahat Hospital, Karachi, Pakistan
Farah Sadia Department of Statistics, PNS Rahat Hospital, Karachi, Pakistan
Humaira Arshad Department of Obstetrics and Gynaecology, PNS Rahat Hospital, Karachi, Pakistan
Aamer Khalil Department of Medicine, PNS Rahat Hospital, Karachi, Pakistan
Abstract
Objective: To compare different cut-off values of fasting and random plasma glucose as a screening test for diagnosis of gestational Diabetes in comparison to the 50 grams Glucose Challenge Test (GCT). Study Design: Comparative, cross-sectional study. Place and Duration of Study: This study was carried out between July 2006 to September 2007 at Departments of Pathology, Obstetrics/Gynaecology and Medicine, PNS Rahat Hospital, Karachi. Methodology: A total of 53 pregnant subjects at 24-28 weeks of pregnancy were selected to undergo random and fasting blood sugar level estimation and 50-g GCT. All the subjects later underwent 100-g OGTT as well. The results were evaluated by both “Carpenter and Coustan criteria” and “NDDG criteria”. The results of random plasma glucose random [cut-off: > 11.1 mmol/L], fasting plasma glucose (cut-off: > 5.3 mmol/L and > 5.1 mmol/L) and plasma glucose results post 50-g GCT (cut-off: > 7.8 mmol/L and > 7.2 mmol/L) were evaluated against 100-g OGTT results through ROC curve analysis. Finally, various diagnostic parameters including sensitivity, specificity, predictive values, likelihood ratios (LR) and efficiency were evaluated. Results: Nineteen subjects were diagnosed to have GDM as per the “Carpenter and Coustan criteria” and 13 met the “NDDG criteria” as per the results of 100-g OGTT. Fasting plasma glucose at was the most efficient investigation at cutoff of 5.1 mmol/L sensitivity=66.66%, specificity=81.25%, PPV=70%, NPV=78.78%, LR+=3.56, LR-=0.41, efficiency=75.47%. At the cut-off value of 5.3 mmol/L, the results had 64% sensitivity, 85.71% specificity, 80% PPV, 72.72% NPV, 4.48 LR+, 0.42 LR-, 75.97% efficiency]. It was followed by plasma glucose post 50-g GCT (53.57% sensitivity at cut-off of > 7.2 mmol/L and 54.54% sensitivity at cut-off of > 7.8 mmol/L). Conclusion: Fasting plasma glucose is a better investigation for the screening of gestational Diabetes than plasma glucose post 50-g glucose challenge.
Publication Details
Page(s) 718-722
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 19, Issue: 11, Year: 2009

Request the full text from PASTIC

Keywords
Gestational Diabetes. Fasting plasma glucose. Glucose challenge test.
0

Citations

0

Downloads

55

Views