No Detail Found!

Effect of Temperature and Preservative on Neo-ethanol Formation in Postmortem Whole Blood Samples

Author(s)
Shakeel Ahmad Department of Chemical Pathology and Endocrinology, Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan
Muhammad Aamir Department of Chemical Pathology and Endocrinology, Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan
Sobia Irum Kirmani Department of Chemical Pathology and Endocrinology, Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan
Zujaja Hina Haroon Department of Chemical Pathology and Endocrinology, Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan
Afshan Bibi Department of Chemical Pathology and Endocrinology, Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan
Usama Bin Khalid Department of Chemical Pathology and Endocrinology, Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan
Abstract
Objective: To determine the association of temperature, time duration, and preservatives with ethanol neo-genesis in postmortem whole blood samples. Study Design: Observational cross-sectional study. Place and Duration of Study: Department of Chemical Pathology and Toxicology, Armed Forces Institute of Pathology, Rawalpindi, in collaboration with Combined Military Hospital, Rawalpindi from August 2020 to January 2021. Methodology: Whole blood samples were obtained from cardiac chamber of an autopsy case with aseptic measures and were drawn into six tubes (3 x EDTA tubes and 3 x NaF tubes). These six tubes were stored at 4ÚC, 25ÚC, and 37ÚC. All samples were analysed along with internal standard, on head space gas-chromatography on Day-0, Day-07, Day-14, Day-21, and Day-28 of sampling. Results: A total of 60 samples out of 10 autopsies, were analysed. Blood alcohol concentrations of all samples were negative on 1st day (Day-0) of analysis. Samples stored at 4ÚC did not produce any ethanol at any day of analysis, regardless of preservatives used. Neo-ethanol levels of blood samples stored in EDTA preservative were signi cantly raised (p <0.001) as compared to samples stored in NaF preservative. Samples stored at 37ÚC showed signi cant increase in neo-ethanol concentration (p <0.001) in comparison with samples stored at 4ÚC and 25ÚC. Neo-ethanol levels increased with duration of storage till 1t4h day of analysis. Conclusion: Sodium uoride (NaF) should be used as preservative to avoid ethanol neo-genesis during storage and transportation of blood samples for alcohol analysis. Cold chain maintenance is of pivotal importance to exclude false positive blood alcohol results.
Publication Details
Page(s) 1159-1162
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 31, Issue: 10, Year: 2021

Request the full text from PASTIC

Keywords
Sodium uoride (NaF), Ethylenediaminetetra acetic acid (EDTA), Neo-ethanol, Neo-genesis
0

Citations

0

Downloads

95

Views