No Detail Found!

Needle breakage as an unusual complication of intravenous therapy: A case report

Author(s)
YanQun Liu Department of Orthopaedic Surgery, Yanbian University Hospital, Yanji, China
HeXing Xu Department of Hand and Foot Surgery, Yanbian University Hospital, Yanji,China
LongYun Fang Department of Imaging, Yanbian University Hospital, Yanji, China
Ji Wen Department of Hand and Foot Surgery, Yanbian University Hospital, Yanji,China
HuZhe Cui Department of Imaging, Yanbian University Hospital, Yanji, China
XiangZheng Qin Yanbian University Medical College, Yanji, China
Abstract
Residual intravenous foreign bodies following hand trauma are relatively rare; only a few previous reports of this situation are available. It has been reported that foreign bodies often migrate to the heart and atrium dextrum. Herein, we report a recent case of needle breakage in the dorsal vein of the hand that was removed with lignicfiation using an intraoperative C-arm fluoroscopy machine and tape tourniquet to avoid proximal movement during removal. The mandate should be to remove within the capacity allowed so that rare cases and terrible complications can be avoided.
Publication Details
Page(s) 1358-1360
Published Journal: Journal of Pakistan Medical Association, Volume: 74, Issue: 7, Year: 2024

Request the full text from PASTIC

Keywords
Complications, Case report, foreign body, Intravenous therapy, Needle breakage