No Detail Found!

Pulmonary Function Test Among University Students-A Cross Sectional Survey

Author(s)
HINA SAEED IQRA University North Campus, Pakistan
RAHILA YOUSUF Dow University of Health Sciences, Pakistan
SOBIA HASAN IQRA University North Campus, Pakistan
M. MUDDASIR ANSARI Principal Karachi Institute of Rehabilitation Sciences, Pakistan
TEHREEM ANIS IQRA University North Campus, Pakistan
SANOWBER AJAZ IQRA University North Campus, Pakistan
Abstract
Objectives: To identify the lung functioning parameters i.e. FVC, FEV1, FEV1/FVC%, MVV of healthy individuals with normal pulmonary function. Study Design: It was a cross-sectional study. Study Setting: Study was conducted at Institute of Physical and Medical Rehabilitation (IPM&R), Dow University of Health Sciences (DUHS), Karachi, Pakistan from August 2022 to January 2023. Methods: Total 60 students giving the male to female ratio of 1:1 with age ranging of 15-30 years were enrolled and studied for respiratory functions by spirometry. Subjects were divided in two groups depending on their gender. The Measured parameters comprised: Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume first second (FEV1), FEV1/FVC%, and maximum voluntary ventilation (MVV). Result: Our results show that all indices, including FVC, FEV1, FVC/FEV1%, and MVV, were statistically significantly (p0.01) greater in males compared to females. Women have a much lower FEV1/FVC ratio than men do (p< 0.05). Out of a total of 60 students, 57.3% (n=34) were classified as having normal spirometry; 15.3% (n=9) were classified as having mild restrictions; 11.7% (n=7) were classified as having moderate restrictions; 1.7% (n=1) were classified as having moderate severe restrictions; 10% (n=6) were classified as having mild obstruction; and 5.3% (n=3) were classified as having moderate obstruction. Practical Implication: Little data exist on whether and how PFT parameters change depending on a person's gender. As a result, we set out to learn more about the differences between the sexes in PFT variables and the connection between BMI and the tests. Conclusion: Our study revealed that males had greater values of FVC, FEV1, FVC/FEV1, and MVV when compared to females, which was statistically significant (p<0.01). Females have a significantly (p0.05) lower FEV1/FVC ratio than males. Our findings demonstrate that healthy male and female subjects breathe in different ways, which may be related to gender's effect on lung function.
Publication Details
Page(s) 255-257
Published Journal: Pakistan Journal of Medical and Health Sciences, Volume: 17, Issue: 3, Year: 2023

Request the full text from PASTIC

Keywords
gender, FVC, FEV1, Pulmonary function, Spirometer, FEV1 /FVC%, MVV, Medical Rehabilitation
0

Citations

0

Downloads

59

Views