No Detail Found!

Frequency of in-Stent Restenosis in patients having DES, with Stent Length Greater than 30mm Presenting to Tertiary Care Center

Author(s)
MUHAMMAD AHMAD RAZA BUTT Department of Cardiology, Rashid Latif Medical College, Lahore, Pakistan
BAKHT UMAR KHAN (CARDIOLOGY), Fellow Interventional Cardiology (AFIC & NIHD), Rawalpindi, Pakistan
MUHAMMAD SAEED AFRIDI Cardiac Surgery, Rashid Latif Medical College, Lahore, Pakistan
MUHAMMAD SULEMAN KHAN Cardiology, Punjab Institute of Cardiology, Lahore, Pakistan
MUJEEBULLAH TAREEN Cardiology Department, Sandeman Provincial Hospital, Quetta, Pakistan
ABDUL HADI Ayub Teaching Hospital Abbottabad, KPK, Pakistan
Abstract
Objective: The purpose of this study was to calculate the incidence of in-stent restenosis in patients with DES and stent lengths higher than 30mm who presented to a tertiary care hospital. Study Design: A Cross-sectional study Place and Duration: This cross-sectional study was conducted at Department of Cardiology, Rashid Latif Medical College, Lahore in the duration from February, 2022 to July, 2022. Methods: There were 83 patients of coronary artery disease (CAD)were included. After obtaining written consent from participants, researchers collected information about their participants' ages, sexes, body mass indexes, and co-morbidities. Atherosclerosis risk variables were collected with baseline investigations and an echocardiography for ejection fraction determination. Imaging studies were reviewed by board-certified interventional cardiologists, who found evidence of ISR. Past angioplasty information and stent details were recorded. Results: In our study mean age of the presented cases was 54.13±7.44 years and mean BMI 25.2±13.87 kg/m2. Most common comorbidity was diabetes found in 25 (30.1%) followed by hypertension in 23 (27.7%) and dyslipidemia in 20 (24.1%) cases. We found that 40 (48.2%) patients were smokers. Mean LDL cholesterol of the patients was 68.6±1.97 mg/dl and mean uric acid was 6.2±2.35 mg/dl. Majority of the cases 45 (54.2%) had poor socio-economic status. We found that frequency of ISR was higher among cases of biomatrix stent 24 (28.9%), followed by Xience stent in 22 (26.5%) cases, Ultimaster stent in 19 (22.9%) and Xlimus stent in 18 (21.7%) cases after coronary angiograpghy. Our results showed that the stents longer than 30mm were associated with a higher incidence of In-Stent Restenosis (p=0.03). Conclusion: Based on the findings of this study, we came to the conclusion that a previous diagnosis of diabetes mellitus and a longer stent length are both significant risk factors for developing in-stent restenosis. In our research, we found that instances with biomatrix stents had a greater incidence of ISR.
Publication Details
Page(s) 827-829
Published Journal: Pakistan Journal of Medical and Health Sciences, Volume: 17, Issue: 1, Year: 2023

Request the full text from PASTIC

Keywords
Coronary angiography, in-stent restenosis, Drug eluting stents (DES)
0

Citations

0

Downloads

106

Views