No Detail Found!

Functional Outcome of an Anatomically Contoured Locking Plate in Intra- Articular Pilon Fracture with MIPO Technique

Author(s)
AATIR JAVAID Shaikh Zayed Hospital,Lahore,Pakistan
USMAN AMJAD Shaikh Zayed Hospital,Lahore,Pakistan
MUHAMMAD ASIF University College of Medicine and Dentistry (UCMD),Lahore,Pakistan
SYED WASIF ALI SHAH Shaikh Zayed Hospital,Lahore,Pakistan
IZZA NASIR Mayo Hospital,Lahore,Pakistan
SAMAN SHAHID National University of Computer & Emerging Sciences (NUCES),Lahore,Pakistan
Abstract
Aim: To evaluate the outcome of osteosynthesis by using anatomically contoured locking plates in the management of intraarticular fractures of tibial plafond with minimally invasive plate osteosynthesis (MIPO) technique Methods: All the 50 patients presenting with intra-articular fractures (Pilon fracture type B and C) in the Accident and Emergency (A&E) department were included in this study. The patients involved in high-energy trauma were treated according to advanced trauma life support guidelines for any associated life- or limb-threatening injuries. The clinical, functional, and radiographic plain anteroposterior and lateral radiographs) evaluations were conducted at 6 months according to Modified Klemm and Borner scoring system and outcome variables i.e. excellent to good was labeled. Results: There were 76% males and 24% females. Most of the patients 23(46%) were in >45 years, age group. Among 50 patients, 28(56%) had type-B fractures, while 22(44%) had type-C fractures. 36(72%) had BMI <30, while 14(28%) had BMI =30. 3(6%) had wound infections. Among 50 patients, 41(82%) had an excellent-good outcome. A good outcome was seen in male patients (78%), as compared to female patients. A good outcome was observed in 39% of patients with age greater than 45 years followed by 32% in 18-30 years. An almost equal percentage of good (56-44%) and poor (55.6-44.4%) outcomes were reported in both types of fractures. 70.7% of patients with BMI <30 reported a good outcome. A good outcome was observed in 41 patients who do not have wound infection. However, 6 patients reported a poor outcome who didn't have wound infection. Conclusion: Plate osteosynthesis using anatomically shaped locking plates via minimally invasive method is an efficient way of stabilization for distal tibia fracture when considering union rates and final functional outcome.
Publication Details
Page(s) 5-7
Published Journal: Pakistan Journal of Medical and Health Sciences, Volume: 16, Issue: 3, Year: 2022

Request the full text from PASTIC

Keywords
Pilon Fracture, Intra-Articular Fracture, Plate Osteosynthesis.
0

Citations

0

Downloads

61

Views