No Detail Found!

Evaluation of post-operative sensitivity of nano filled composite versus bulkfilled resin composite in posterior class 2 restoration

Author(s)
Sadia Channa Department of Operative Dentistry, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan
Fozia Rajput Department of Operative Dentistry, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan
Afreen Bilgrami Department of Science of Dental Materials, Fatima Jinnah Dental College, Karachi, Pakistan
Farhan Javed Department of Periodontology, Avicenna Medical and Dental College, Lahore, Pakistan
Hira Faraz Department of Operative Dentistry, Dow Dental College, Dow University of Health Sciences, Karachi, Pakistan
Madiha Department of Operative Dentistry, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan
Abstract
Dental composites use adhesives to adhere and are thermally non-conductive. Despite advances in restorative dentistry, adhesive restorations may cause postoperative pain and fail. Objective: To compare and evaluate the post-operative sensitivity between nano resin composite using incremental technique and bulk lled resin composite using bulk lled technique in class 2 posterior restorations by assessing the post-operative pain and sensitivity. Methods: Two hundred and twenty patients who satis ed inclusion and exclusion criteria were lottery-divided into groups A and B. Nano resin composite was placed via incremental technique in Group A and bulk lled in Group B. Post-operative pain was assessed using Visual Analog Scale 0-10 at 24 hours and 7 days. Results: Male patients were 47 (42.7%) and 48 (43.6%), female patients were 63 (57.3%) and 62 (56.4%). Mean of pain was 2.39 ± 0.97 and 2.32 ± 0.81 at 24 hours postoperatively and 0.14 ± 0.63 and 0.00 at 7 days in group A and group B respectively. Pain level was mild in 97 (88.2%) and 105 (95.5%) patients, moderate in 13 (11.8%) and 5 (4.5%) after 24 hours, no pain in 105 (95.5%) and 110 (100.0%) and mild in 5 (4.5%) and 0 (0.0%) at 7 days in group A and group B, respectively. Conclusion: Bulk lled resin composite using bulk lled technique is more effective in class 2 posterior restorations as compared to nano resin composite using incremental technique.
Publication Details
Page(s) 14-18
Published Journal: Pakistan Journal of Health Sciences, Volume: 4, Issue: 4, Year: 2023

Request the full text from PASTIC

Keywords
sensitivity, pain, Nano lled, Bulk Filled Composite, Incremental
0

Citations

0

Downloads

41

Views