Environment Friendly, Low Energy, Heating, Ventilation and Air Conditioning (HVAC) System, Using Water Medium as a Heat Exchanger

Author(s)
S. Hussain. Department of Environmental Sciences, University of Peshawar, Peshawar 25120, Pakistan
H. Khan Department of Environmental Sciences, University of Peshawar, Peshawar 25120, Pakistan
H. A. Qureshi Earthquake Engineering Center, Department of Civil Engineering, University of Engineering and Technology,Peshawar,Pakistan
Abstract
Now that there is an ever-increasing demand of energy all over the world and the subsequent problem of global warming and climate change due to rise in the level of carbon dioxide in the atmosphere; there is an intense need for a cooling/heating system which would be energy efficient and environment friendly. The conventional air conditioning system consumes a lot of energy, which has a major contribution to present energy crises globally. Moreover, it is responsible for large emissions of CO2, chlorofluorocarbons (CFCs) and hydrofluorocarbons (HFCs). CO2, particulate matter, and other air pollutants are also produced due to burning of fuel wood and fossil fuel for heating in the winter season. The objective of this study was to devise an economical, environment friendly and low energy HVAC system. The novelty of the proposed HVAC system is that it uses no compressor and no evaporation technique for cooling. No humidity problem, there is only an exchange of heat between water and air. The system is capable to deliver air at the temperature of fresh groundwater of that city or location in any season of the year. A simple experimental method was adopted to test the proposed HVAC system i.e. air was blown in pipe which passed through water medium. Temperature of the system air at outlet was measured and recorded in the form of a table for various lengths of the pipe. Results show that atmospheric air assumed the temperature of water, as it passed through it in a plastic or copper pipe. The suitable length for copper pipe and plastic pipe was experimentally determined i.e. the length of pipe at which the temperature of system air and that of water medium becomes more or less equal. In case of fresh groundwater as a medium the suitable length for copper pipe was less than 2.44 feet, while for plastic pipe the suitable length was 20 feet. In Peshawar the groundwater temperature is 23.38 OC and in majority of the cities of Pakistan the groundwater temperature lies in the range of 17 to 27 OC, so, the proposed HVAC system would work efficiently in most of the cities of Pakistan.
Publication Details
Page(s) 9-17
DOI DOI not available
Published Journal: Technical Journal, Volume: 28, Issue: 2, Year: 2023

Request the full text from PASTIC

Keywords
fresh air blown in pipe passed through water tank, no increase in humidity, - Energy saver cooling/heating system, fresh air supplied to the building, no use of compressor, water as refrigerant, water air heat exchange