Effect of reperfusion on time domain parameters of heart rate variability

Author(s)
Sadia Mubarak Islamabad Medical and Dental College., Pakistan
Bushra Riaz Pak International Medical College.Pakistan
Mehwish Ashfaq Department of Physiology, HITEC-Institute of Medical Sciences (IMS) Taxila.Pakistan
Sidra Hamid Department of Physiology, Rawalpindi Medical University.Pakistan
Amina Rasul Watim Medical College, Rawalpindi.Pakistan
Mamoona Shafiq Department of Physiology, Islam Medical College, Sialkot, Pakistan
Abstract
Objective: To compare the effect of reperfusion by measuring time domain parameters of heart rate variability before and after percutaneous transluminal coronary angioplasty. Study design: Quasi-experimental study design Place and Duration: Department of Clinical Cardiac Electrophysiology, Armed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD), Rawalpindi in 2018. Patients and Methods: 40 patients with coronary artery disease having a mean age of 55.20 ± 8.03 years were recruited by non-probability convenience sampling. DMS 300-4A Holter monitors were used to obtain 24 hours of ambulatory ECG recording before and within 24 hours after percutaneous transluminal coronary angioplasty. Digital ECG data were transferred to the computer and edited with the help of DMS Cardio scan software. Heart rate variability was analyzed in time domain measures. For time domain analysis normal heart rate, SDNN, SDNNi, SDANN, RMSSD, and pNN50 were recorded from 12 lead digital ECG data. Results: The results of our study demonstrated significantly decreased heart rate variability in coronary artery disease patients on comparison of pre and post-angioplasty values only SDNNi was significantly reduced (pvalue = 0.035) whereas the reduction in SDNN and pNN50 was statistically insignificant (p-value > 0.05). On the contrary, SDANN and RMSSD displayed a slight rise after angioplasty, but it was not significant (p-value > 0.05). Conclusion: Reperfusion after percutaneous transluminal coronary angioplasty decreases heart rate variability within 24 hours after the procedure. Whereas heart rate during the same period after angioplasty increases. This reflects autonomic balance shifts towards sympathetic predominance as indicated by reduced heart rate variability and a rise in heart rate. This makes the susceptible patients vulnerable to the development of ventricular arrhythmias, especially during 24 hours after angioplasty. Therefore, patients with decreased heart rate variability are at risk of ventricular arrhythmogenesis so they may be kept under medical surveillance for at least 24 hours after percutaneous transluminal coronary angioplasty.
Publication Details
Page(s) 225-230
Published Journal: Journal of Rawalpindi Medical College, Volume: 27, Issue: 1, Year: 2023

Request the full text from PASTIC

Keywords
Coronary artery disease, ischemia, Heart rate variability, Holter monitoring