Comparison of electrocautery and ligasure in terms of per-operative blood loss in modified radical mastectomy

Author(s)
Soofia Irfan Department of Surgery, Faisalabad Medical University, Faisalabad Pakistan
Sajid Rehman Randhawa Department of Surgery, Faisalabad Medical University, Faisalabad Pakistan
Habib Qadir Department of Surgery, Fatima Jinnah Medical University, Lahore Pakistan
Muhammad Saleem Iqbal Department of Surgery, Faisalabad Medical University, Faisalabad Pakistan
Nabeel Akhtar Department of Surgery, Allied Hospital, Faisalabad Pakistan
Tayba Latif Department of Surgery, Allied Hospital, Faisalabad Pakistan
Abstract
Background: Carcinoma breast is the second most commonly diagnosed cancer worldwide. Mastectomy is the most practiced surgical treatment for breast cancer patients; The LigaSure Small Jaw is the modren bipolar vessel sealing system utilized for coagulation as well as cutting. Objective: The objective of the study was to compare mean intra operative blood loss using electrocautery versus ligasure in modified radical mastectomy in breast carcinoma patients. Study Design: Randomized controlled trial. Settings: Department of Surgery, Allied Hospital, Faisalabad. Duration: One year from June 01, 2019 to May 31, 2020. Methods: After taking approval from hospital ethical committee, patients fulfilling the inclusion criteria were admitted through OPD, and enrolled for the study. Informed consent was taken. All the patients were randomly divided into two groups. Group A patients underwent modified radical mastectomy using ligasure and Group B patients underwent modified radical mastectomy using electrocautery. Both the procedures were performed by senior surgeon. Intra operative blood loss was estimated. All the information was collected on proforma. Results: Comparison of mean intra operative blood loss in modified radical mastectomy using LigaSure with electrocautery in patients of breast cancer shows that 70.52 ± 1.22 ml is lost in Group-A and 87.04 ± 1.41 ml in Group-B, p value was 0.001. Conclusion: We concluded that mean intra operative blood loss using LigaSure is significantly lower when compared with using electrocautery for performing modified radical mastectomy in breast carcinoma.
Publication Details
Page(s) 14-17
Published Journal: Annals of Punjab Medical College, Volume: 17, Issue: 1, Year: 2023

Request the full text from PASTIC

Keywords
Breast Cancer, Modified radical mastectomy, Intraoperative blood loss, electrocautery, Ligasure