No Detail Found!

Do Respiratory Maneuvers Affect Right Hepatic Vein Waveform and Maximum Velocity in Post LDLT Recipients?

Author(s)
Muhammad Salman Rafique Pakistan Kidney and Liver Institute and Research Center, Lahore, Pakistan
Bushra Bilal Pakistan Kidney and Liver Institute and Research Center, Lahore, Pakistan
Sana Kundi Pakistan Kidney and Liver Institute and Research Center, Lahore, Pakistan
Tahir Malik Pakistan Kidney and Liver Institute and Research Center, Lahore, Pakistan
Kayenat Khan Pakistan Kidney and Liver Institute and Research Center, Lahore, Pakistan
Huma Hussain Pakistan Kidney and Liver Institute and Research Center, Lahore, Pakistan
Abstract
To evaluate the effect of respiratory maneuvers on the right hepatic 1,2Conception, Synthesis and Planning vein (RHV) Doppler waveform and its maximum velocity in living donor liver 3oDfitshceursessioena,rc4Ihn,teRrepvreietwatitohne, SDtautday transplant (LDLT) recipients. analysis , 5,6Active participation in Methodology: This was a prospective cross-sectional study performed at active methodology Pakistan Kidney and Liver Institute and Research Centre (PKLI& RC), Lahore from Funding Source: None February 1, 2022, to March 31, 2022. The sample size of the study, calculated Conflict of Interest: None according to WHO sample size calculator, was 30 patients after applying the Received: Mar 04, 2023 inclusion and exclusion criteria. Most of these patients were analyzed during their Accepted: Aug 28, 2023 first post-operative week while staying in the surgical intensive care unit (SICU). Address of Correspondent The Doppler waveform and maximum velocity of RHV were recorded during Dr. Muhammad Salman Rafique normal gentle breathing, following breath-hold after deep inspiration and then Consultant Radiologist Pakistan after quiet expiration. The waveforms that were recorded were triphasic, Kidney and Liver Institute and biphasic, or monophasic in the pattern. To assess the RHV flow quantitatively, the Research Center, Lahore damping Index was also calculated during all these three respiratory maneuvers msalmanrafique@gmail.com as follows (DI=Minimum velocity/maximum velocity) Results: The maximum velocities during normal respiration, after quiet expiration, and after breath-holding following deep inspiration were 125 cm/sec, 105 cm/sec and 94 cm/sec. The waveforms observed during gentle breathing were triphasic in 77%, biphasic in 10%, and monophasic in 13% of the patients. After quiet expiration, these were triphasic in 80%, biphasic in 6%, and monophasic in 13% of patients. However, after breath-hold following deep inspiration, the waveforms observed were triphasic in 42%, biphasic in 13%, and monophasic in 45% of the patients. (P <0.008) Conclusion: The study showed that not only did the RHV waveforms show significant change from triphasic pattern to monophasic pattern, but also the peak velocities were lower following expiration. Therefore, during the Doppler ultrasound assessment of post-LDLT recipient patients, respiratory variations must be taken into consideration.
Publication Details
Page(s) 289-293
Published Journal: Annals of the Pakistan Institute of Medical Sciences, Volume: 19, Issue: 3, Year: 2023

Request the full text from PASTIC

Keywords
Doppler ultrasonography, hepatic vein, Vascular complications.
0

Citations

0

Downloads

103

Views