No Detail Found!

Intraocular Pressure Change After Low Energy and High Energy ND:YAG Laser Posterior Capsulotomy

Author(s)
Urwa Ghafoor Department of Ophthalmology, Fauji Foundation Hospital,Rawalpindi,Pakistan
Asfandyar Asghar Department of Ophthalmology, Fauji Foundation Hospital,Rawalpindi,Pakistan
Rana Intisar Ul Haq Department of Ophthalmology, Fauji Foundation Hospital,Rawalpindi,Pakistan
Maham Fazal Department of Ophthalmology, Fauji Foundation Hospital,Rawalpindi,Pakistan
Tehmina Nazir Department of Ophthalmology, Fauji Foundation Hospital,Rawalpindi,Pakistan
Naila Obaid Department of Ophthalmology, Fauji Foundation Hospital,Rawalpindi,Pakistan
Abstract
T Objective: To determine the frequency of intraocular pressure (IOP) changes among patients undergoing YAG Laser Posterior Capsulotomy and to compare IOP changes based on the level of YAG laser energy and the number of shots applied. Methodology: A descriptive cross-sectional study was conducted at the Department of Ophthalmology, Fauji Foundation Hospital Rawalpindi, from December 2021 to November 2022. A total of 200 pseudophakic eyes with posterior capsular opacification. Baseline intraocular pressure (IOP) was measured using Goldman Applanation Tonometry (GAT). Patients were categorized into groups based on the laser energy used and the number of shots. IOP measurements were taken at 1 and 4 hours after the procedure, and the results were compared. Results: In the low-energy group, the mean pre-procedure IOP was 13.44 ± 2.91 mmHg. After 1 and 4 hours, the IOP values were 14.86 ± 3.36 mmHg and 12.97 ± 3.16 mmHg, respectively. In the high-energy group, the mean pre-procedure IOP was 14.31 ± 3.16 mmHg, and it increased to 19.42 ± 6.55 mmHg and 17.51 ± 5.19 mmHg after 1 and 4 hours of the procedure, respectively. In group 1 (less than 20 shots), the mean IOP at 1 and 4 hours post-procedure was 13.88 mmHg and 12.97 mmHg, respectively. In group 2 (greater than 20 shots), the mean IOP values were 21.63 mmHg and 18.31 mmHg, respectively. The increase in IOP was significantly higher in the group with higher laser energy and a greater number of shots at both 1 and 4 hours (p=0.000). Conclusion: In conclusion, our study found that a significant rise in IOP is observed when higher energy and a greater number of shots are used in YAG laser capsulotomy.
Publication Details
Page(s) 235-239
Published Journal: Annals of the Pakistan Institute of Medical Sciences, Volume: 19, Issue: 3, Year: 2023

Request the full text from PASTIC

Keywords
intraocular pressure change, ND:YAG laser energy, Pseudophakia
0

Citations

0

Downloads

49

Views