No Detail Found!

Diagnostic Accuracy of Magnetic Resonance Arthrography and its Correlation with Arthroscopy in the Detection of Lesions Triangular Fibrocartilaginous Complex and Intrinsic Ligaments in the Wrist

Author(s)
Naushaba Malik PESSI Hospital, Islamabad, Pakistan
Tehmina Sajjad Khan Islamabad Diagnostic Center, Sangjani, Rawalpindi, Pakistan
Shah Bakht Aftab Trainee, PIMS, Islamabad, Pakistan
Minnal Ahmed Malik PIMS, Islamabad, Pakistan
Abstract
To assess the diagnostic validity and reliability of magnetic conception or design of the work; or resonance arthrography in identifying the lesion of triangular intrinsic wrist the acquisition, analysis, or ligaments and fibrocartilaginous complex based on arthroscopy as reference interpretation of data for the work standard and preferred modality of imaging. and final approval of the version to Methodology: This was a retrospective validation study that was carried out be published,2,3Drafting the work or at the Radiology department of PESSI (Punjab Employees Social Security) revising it critically for important Hospital, Islamabad, between April 2019 and September 2022. A total of 11 intellectual content, 4 literature patients with an age range 21-58 years, lesions of the triangular review fibrocartilaginous complex (TFCC), and MR arthrography were included. MR Funding Source: None arthrography images of the wrist were evaluated to assess the integrity of the Conflict of Interest: None intrinsic wrist ligaments, including those of the TFCC, scapholunate, and Received: January 11, 2023 lunotriquetral ligament. MR arthrography injection was performed into the Accepted: March 21, 2023 wrist joint, likely to help visualize the ligaments and other structures within the Address of Correspondent joint. The dye was injected under fluoroscopic guidance, the size of the needle Dr Naushaba Malik used for the injection was 20-24G. The data collected from the MR Head of Radiology, PESSI Hospital, arthrograms and arthroscopy was analyzed using SPSS v 23. IDsolacmtoarb.Naodshi100@gmail.com tRheesrueltsw:eTrhee 6pat(5ie5n.5t'%s)mmeaanleasgeanwdas54(04.05±.51%2).31feymeaalress..OSuetnosifti1v1itypaotfienMtsR, arthrography is 71.4% and specificity that of 75% for detecting TFCC defects, and a 100% sensitivity and 85.7% specificity for diagnosing intrinsic ligament defects. MR arthrography had an overall accuracy of 73% for detecting TFCC, while the overall accuracy for detecting intrinsic ligament defects was 90.9%. Conclusion: MR arthrography was an adequate diagnostic tool for detecting defects of the intrinsic ligaments and the TFCC of the wrist when compared to diagnostic arthroscopy.
Publication Details
Page(s) 29-34
Published Journal: Annals of the Pakistan Institute of Medical Sciences, Volume: 19, Issue: 1, Year: 2023

Request the full text from PASTIC

Keywords
Arthroscopy, Magnetic resonance, Arthrography, Wrist joint, Ligaments, Fibrocartilaginous
0

Citations

0

Downloads

80

Views