Acceptability of Vacuum-formed Retainers & Hawley Comparative Assessment of Patient's Acceptability between Hawley and Vacuum-Formed Retainer in Patients Treated with Fixed Orthodontics Appliance

Author(s)
Khadija Bibi Department of Orthodontics, Armed Forces Institute of Dentistry/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Abdullah Jan Department of Orthodontics, Armed Forces Institute of Dentistry/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Munza Hameed Department of Orthodontics, Armed Forces Institute of Dentistry/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Nimra Afgan Department of Orthodontics, Armed Forces Institute of Dentistry/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Haseeb Alamzeb Department of Orthodontics, Armed Forces Institute of Dentistry/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Sundas Malik Department of Orthodontics, Armed Forces Institute of Dentistry/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Abstract
Objective: To compare the acceptability of Vacuum-formed Retainers and Hawley Retainers in two groups of fixed orthodontics patients over three months. Study Design: Quasi-experimental study. Place and Duration of Study: Armed Forces Institute of Dentistry, Rawalpindi Pakistan, from Jan 2019 to Mar 2020. Methodology: Eighty-two Patients treated with fixed orthodontics appliances in the department of orthodontics of Armed Forces Institute of Dentistry, who met the inclusion and exclusion criteria were recruited for the study. Patient acceptance was evaluated through a ten-question questionnaire regarding biting, fitting, hygiene, speech, swallowing, appearance, selfconfidence, gingival irritation, durability and comfort. Patients were evaluated on a 10cm long Visual analogue scale over three months in the post-orthodontics retention phase, after one week (T1), one month (T2) and three months (T3) of follow-up. Results: The vacuumed-formed retainer was significantly better in terms of speech (p<0.01), appearance (p<0.001), durability (p<0.001), gingival irritation (p<0.001), swallowing (p<0.001), self-confidence, and comfort (p<0.001). There was no significant difference in terms of fitting, hygiene and biting. Conclusion: The vacuumed-formed retainer was significantly better accepted in terms of speech, swallowing, appearance, selfconfidence, durability, gingival irritation and comfort.
Publication Details
Page(s) 682-685
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 73, Issue: 3, Year: 2023

Request the full text from PASTIC

Keywords
retention, Relapse, Retainers, Malaligned teeth