Comparison of Hemodynamic Changes after Intubation with Macintosh and McCoy Laryngoscopes-A Randomised Controlled Trial

Author(s)
Muhammad Awais Qarni Combined Military Hospital, Jhelum /National University of Medical Sciences (NUMS),,Pakistan
Salma Nisar Combined Military Hospital, Kharian /National University of Medical Sciences (NUMS) Pakistan
Fawad Alam Combined Military Hospital, Jhelum /National University of Medical Sciences (NUMS),,Pakistan
Tariq Mehmood Medical Battalion, Gilgit Baltistan, Pakistan; Combined Military Hospital, Jhelum /National University of Medical Sciences (NUMS) Pakistan, Combined Military Hospital, Kharian /National University of Medical Sciences (NUMS) Pakistan
Mashooque Ali Army Medical College/National University of Medical Sciences (NUMS) Rawalpindi Pakistan,
Sarah Nisar Combined Military Hospital, Rawalakot/National University of Medical Sciences (NUMS) Pakistan,
Abstract
Objective: To compare hemodynamic changes (systolic blood pressure and pulse) after intubation with Macintosh and McCoylaryngoscopes.Study Design: Randomised control trial (Clinicaltrials.gov: NCT05133375)Place and Duration of Study: Combined Military Hospital, Jhelum Pakistan, from Apr to Oct 2021.Methodology: A group of 272 patients reporting to the operation theatre were selected and divided into Group-A and B usingthe lottery method. All patients had ASA class I and II score and Mallampati score of I and II with no comorbid conditions.Macintosh laryngoscope was used in Group-A, and McCoy laryngoscope was used in Group-B. Before intubation, systolicblood pressure and pulse were measured, as well as 30 seconds, 2 minutes, and 3 minutes following intubation. In addition, acomparison of both groups regarding systolic blood pressure and pulse was made.Results: The patients in the study had a mean age of 34.93±9.66 years. The increase (20%) in heart rate was significantly higherin the Macintosh-Group 23(16.9%), than in the McCoy-Group 8(4.4%), (p=0.001), and the 20% increase in systolic pressure wasalso found to be significantly higher in the Macintosh-Group as compared to the McCoy-Group, 26(19.1%) versus 8(6.6%),(p=0.002).Conclusion: According to our research, using the McCoy blade is a safer mode of intubation in terms of the hemodynamic response.
Publication Details
Page(s) 460-463
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 73, Issue: 2, Year: 2023

Request the full text from PASTIC

Keywords
Hemodynamics, Endotracheal intubation, Laryngoscopes