No Detail Found!

Agreement between Subjective and Objective Parameters Using Meibography for Assessment of Dry Eye Syndrome

Author(s)
Ijlal Taimoor Department of Ophthalmology, Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Syed Abid Hassan Naqvi Department of Ophthalmology, Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Taimoor Ashraf Khan Department of Ophthalmology, Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Saquib Naeem Department of Ophthalmology, Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Waseem Yousaf Department of Ophthalmology, Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Muhammad Usman Ghani Department of Ophthalmology, Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Abstract
Objective: To determine the agreement between subjective and objective parameters using meibography. Study Design: Cross-sectional observational study. Place and Duration of Study: Armed Forces Institute of Ophthalmology (AFIO), Rawalpindi Pakistan from August 2021 till February 2022. Methodology: 100 patients were included in the study. Non-contact infra-red meibography was performed on each patient. Subjective assessment was done using the four-grade and five-grade scales while objective assessment was done by applying computerized grading. Results: A total of one hundred (n=100) patients participated in the study. Out of total, 60% patients were male and 40% were females, with a mean age 42.25±14.9 years. There was statistically significant difference was seen Session I OII vs Session II OII as p-value <0.001 in Grade-4, Session-I OIII vs Session-II OIII as p-value <0.001 in Grade-5. There was not statistically significant difference seen in Computerized Grading (100-grade scale) as p-value >0.05. Correlations between observers was best with the 5-grade scale followed by the computerized 100-grade scale and 4-grade scale. Conclusions: We found that the reliability of the 5-grade scale was poorer to that of the 4-grade scales. We also concluded that computerized grading offers a better intra and inter-observer assessment.
Publication Details
Page(s) 374-377
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 73, Issue: S1-2, Year: 2023

Request the full text from PASTIC

Keywords
Dry eye disease, Computerized grading system, Subjective grading system., Objective grading system, Meibography
0

Citations

0

Downloads

136

Views