No Detail Found!

Effect of immersion and incorporation of polyvinyl chloride on the flexural strength and micro hardness of polymethylmethacrylate denture base resin

Author(s)
Shahid Ilyas Department of Dental Material, Khyber Medical University Institute of Dental Sciences, Kohat, Pakistan; Department of Dental Material Peshawar Dental College, Riphah International University, Pakistan.
Amjad Hanif Department of Dental Material Peshawar Dental College, Riphah International University, Pakistan.
Abstract
OBJECTIVE: To find the effect of artificial saliva, water and different percentages of polyvinyl chloride (PVC) on the flexural strength and microhardness of heat cure polymethylmethacrylate (HC-PMMA) denture base resin. METHODS: An in-vitro study conducted, from April-December, 2020, at the MRL University of Peshawar and Interdisciplinary Research Centre in Biomedical Materials (COMSATS) Lahore. Total of 100 specimens for five groups (n=20) denoted by A, B, C, D and E containing 0%, 5%, 10%, 15% and 20% PVC in HCPMMA respectively were fabricated to test flexural strength. Each group was divided into two subgroups depending on immersion medium containing ten specimens each. Three-point bending test was used to determine flexural strength. Microhardness was determined using thirty (n=30) specimens through Vickers hardness tester. Statistical analysis was performed by using one way ANOVA and post hoc Tukey test. P-value <0.05 was considered as significant. RESULTS: After immersion in water, one way ANOVA showed significant effect on flexural strength and Post-hoc Tukey's test showed significant difference between group C and E (p<0.001) and, D and E (p< 0.001). Microhardness of A was significantly different from E after immersion in water (p<.05). Similarly, after immersion in artificial saliva, one way ANOVA showed statistically significant effect on microhardness (p< 0 .01) and Post-hoc Tukey's test showed significant difference between group C and E (p<0.01) and, A and C (p<0.01). CONCLUSION: Flexural strength of HC-PMMA impregnated with 20% PVC increased after immersion in water, similarly, HC-PMMA containing 10% PVC shows increased microhardness after immersion in artificial saliva.
Publication Details
Page(s) 184-189
Published Journal: Khyber Medical University Journal, Volume: 14, Issue: 3, Year: 2022

Request the full text from PASTIC

Keywords
Acrylic denture (Non-MeSH), Acrylic Resins (MeSH), Flexural Strength (MeSH), Dental Bases (MeSH), Polymethyl Methacrylate (MeSH), Polyvinyl Chloride (MeSH), Hardness (MeSH), Hardness Tests (MeSH), Heat cure polymethylmethacrylate (Non-MeSH)
0

Citations

0

Downloads

42

Views