Objective: To determine the frequency of blood and blood products transfusions fulfilling appropriate criteria of blood transfusion in a tertiary care hospital Study Design: Cross sectional study Place and Duration of Study: General Medical Wards & Emergency Department, Children’s Hospital Lahore & University of Child Health Sciences, Lahore, 06 months (1st July to 31st December 2018). Material and Methods: 200 children fulfilling the inclusion criteria were included from Children’s Hospital Lahore & University of Child Health Sciences. Transfusions were labelled appropriate if fulfilling the national and international guidelines and data analysis was done. Results: Over a period of 6 months, 200 patients were studied. Out of 200 transfusions, 104 (52%) took place in emergency department while 96 (48%) in wards. In blood components, the proportions of whole blood, packed cells, platelets and fresh frozen plasma were 78 (39%), 75 (37.5%), 22 (11%) and 25 (12.5%) respectively. According to standard transfusion protocols, 93 (46.5%) transfusions were appropriate. The data was stratified according to age, gender, type and place of transfusion. The results showed that there was no effect of these modifiers as the p value for age, gender, type and place of transfusion were 0.537, 0.356, 0.916 and 0.503 respectively. Conclusion: Most of the blood transfusions in the tertiary care hospital were not carried out according to the standard tranfusions protocols and indications. More research should be done in this area to allow us to guage the severity of the problem locally.