No Detail Found!

Clinical characteristics of patents who developed slow flow/ no-reflow after post-dilatation with non- compliant balloon during primary percutaneous coronary intervention

Author(s)
Chandar Parkash National Institute of Cardiovascular Diseases,Karachi,Pakistan
Vashu Mal National Institute of Cardiovascular Diseases,Karachi,Pakistan
Asim Shaikh National Institute of Cardiovascular Diseases,Karachi,Pakistan
Dileep Kumar National Institute of Cardiovascular Diseases,Karachi,Pakistan
Rameez Ahmed National Institute of Cardiovascular Diseases,Karachi,Pakistan
Sara Masood National Institute of Cardiovascular Diseases,Karachi,Pakistan
Jehanghir Ali Shah National Institute of Cardiovascular Diseases,Karachi,Pakistan
Bashir Ahmed National Institute of Cardiovascular Diseases,Karachi,Pakistan
Naveedullah Khan National Institute of Cardiovascular Diseases,Karachi,Pakistan
Jawaid Akbar Sial National Institute of Cardiovascular Diseases,Karachi,Pakistan
Abstract
Objectives: Post-dilatation with non-compliant (NC) balloons is a commonly used strategy to improve inadequate stent expansion but this strategy carries an increased risk of slow flow/no reflow (SF/NR) due to distal embolization. Therefore, our objective was to evalua te the demographic, clinical, angiographic, and procedure characteristics among patients undergoing primary percutaneous coronary intervention (PCI) who developed slow flow/no -reflow (SF/NR) after post-dilatation with non-compliant (NC) balloons. Methodology: In this cross-sectional observational study, we included consecutive patients with SF/NR after post-dilatation using NC balloon post stent deployment during primary PCI. The demographic, clinical, angiographic, and procedure characteristics were eva luated. Results: In the sample of 107 patients, male were 77.6% (83) and mean age was 56.94 ± 10.47 years. The median chest pain to ER (emergency room) arrival time was 292 [180 -394] minutes. A majority of the patients (66.4%) had multi-vessel disease. Mean length NC balloon was 10.57±1.98 mm and diameter was 3.5±0.26 mm. The mean number of inflation were 3.62±1.08, at mean maximal pressure of 20.43±2.49 mmHg, proximal edge pressure of 19.25±2.74 mmHg, and distal edge pressure of 14.64±2.01 mmHg. A total of 5.6% (6) patients developed adverse events and final TIMI (thrombolysis in myocardial infarction) III flow was achieved in 89.7% (96) of the patients. Conclusion: SF/NR after post-dilatation during primary PCI is associated with a significant rate of adverse events and sub-optimal (<III) final TIMI flow. The detrimental effects of high pressure, short length, and increased number of inflations on post NC SF/NR need further investigations.
Publication Details
Page(s) 110-114
Published Journal: Pakistan Heart Journal, Volume: 56, Issue: 1, Year: 2023

Request the full text from PASTIC

Keywords
primary percutaneous coronary intervention (PCI), non-compliant (NC) balloon, slow flow/no-reflow (SF/NR), ST-segment elevation myocardial infarction (STEMI)
0

Citations

0

Downloads

49

Views