No Detail Found!

Estimation of cardiac doses during breast cancer radiotherapy in Pakistan

Author(s)
Javaid Ali Larkana Institute of Nuclear Medicine and Radiotherapy (LINAR), hospital Larkana,,Pakistan
Attia Gul Institute of Nuclear Medicine,Oncology and Radiotherapy (INOR), hospital Abbottabad,Pakistan
Muhammad Basim Kakakhel Pakistan Institute of Engineering and Applied Sciences (PIEAS),Islamabad,Pakistan
Imadullah Tariq Larkana Institute of Nuclear Medicine and Radiotherapy (LINAR), hospital Larkana,,Pakistan
Muhammad Sohail International Collaborative Laboratory of 2D Materials for Optoelectronics Science and Technology of Ministry of Education, Institute of Microscale Optoelectronics, College of Electronics and Information Engineering, Shenzhen University,Shenzhen, 518060,China
Ghufran Biradar Swat Institute of Nuclear Medicine,Oncology and Radiotherapy (SINOR), Swat,Pakistan
Rashid Khan School of Energy and Power Engineering, Xi'an Jiaotong University (XJTU),28 Xianning W. Rd., Xi'an 710049,China
Abdul Samad Larkana Institute of Nuclear Medicine and Radiotherapy (LINAR), hospital Larkana,,Pakistan
Israr Ahmad Larkana Institute of Nuclear Medicine and Radiotherapy (LINAR), hospital Larkana,,Pakistan
Abstract
This study aims to estimate the absorbed radiation doses to the heart during breast cancer treatment with conventional radiotherapy. The cardiac doses of eighty-three patients during breast cancer radiotherapy were estimated, with fifty-two patients having left breast cancer and thirty-one having right breast cancer. For left breast cancer patients, a treatment planning system (TPS) was used to estimate the percentage volume of the heart receiving 20 Gy [V20 (%)], 25 Gy [V25 (%)], 30 Gy [V30 (%)], and 40 Gy [V40 (%)]. The maximum heart distances (MHD) within the radiation field for left breast cancer patients and the minimum distance of heart from the posterior border of the radiation field (MDHF) for right breast cancer patients were measured. Through TPS, the mean dose to the 5% and 10% heart volumes, the lowest dose (Dmin), the maximum dose (Dmax), and the average dose (Davg) of the heart for all patients with left and right breast cancer were also calculated. For patients with left breast cancer, higher mean values of V20 (%), V25 (%), V30 (%), and V40 (%) were estimated and a direct correlation between MHD and Davg was observed. The relationship between MDHF and Davg in patients with right breast cancer was observed to be linear but with a negative slope. Patients undergoing radiotherapy for left breast cancer receive higher doses and are therefore recommended for assessment of cardiac complications during follow-ups.
Publication Details
Page(s) 409-416
DOI DOI not available
Published Journal: International Journal of Biology and Biotechnology, Volume: 20, Issue: 3, Year: 2023

Request the full text from PASTIC

Keywords
Radiotherapy, dose-volume histogram (DVH), Cardiac dose
0

Citations

0

Downloads

85

Views